Advances in photoplethysmography: beyond arterial oxygen saturation

被引:0
|
作者
Bartels, Karsten [1 ,2 ]
Thiele, Robert H. [3 ,4 ,5 ,6 ]
机构
[1] Univ Colorado Denver, Dept Anesthesiol, Aurora, CO USA
[2] Univ Colorado Denver, Dept Surg, Aurora, CO USA
[3] Univ Virginia, Sch Med, Dept Anesthesiol, Div Cardiac, Charlottesville, VA 22908 USA
[4] Univ Virginia, Sch Med, Dept Anesthesiol, Div Thorac, Charlottesville, VA 22908 USA
[5] Univ Virginia, Sch Med, Dept Anesthesiol, Div Crit Care Anesthesiol, Charlottesville, VA 22908 USA
[6] Univ Virginia, Sch Med, Dept Biomed Engn, Charlottesville, VA 22908 USA
关键词
PLETH VARIABILITY INDEX; PREDICT FLUID RESPONSIVENESS; WAVE-FORM AMPLITUDE; MECHANICALLY VENTILATED PATIENTS; CONTINUOUS CARDIAC-OUTPUT; SYSTOLIC BLOOD-PRESSURE; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; STROKE VOLUME VARIATION; PULSE TRANSIT-TIME;
D O I
10.1007/s12630-015-0458-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose Photoplethysmography permits continuous measurement of heart rate and peripheral oxygen saturation and has been widely used to inform clinical decisions. Recently, a myriad of noninvasive hemodynamic monitoring devices using this same technology have been increasingly available. This narrative review aims to summarize the principles that form the basis for the function of these devices as well as to comment on trials evaluating their accuracy and clinical application. Principal findings Advanced monitoring devices extend photoplethysmography technology beyond measuring oxygen concentration and heart rate. Quantification of respiratory variation of the photoplethysmographic waveform reflects respiratory variation of the arterial pressure waveform and can be used to gauge volume responsiveness. Both the volume-clamp and physiocal techniques are extensions of conventional photoplethysmography and permit continuous measurement of finger arterial blood pressure. Finger arterial pressure waveforms can subsequently inform estimations of cardiac output. Conclusions Although respiratory variations of the plethysmographic waveform correlate only modestly with the arterial blood pressure waveform, fluid responsiveness can be relatively consistently assessed using both approaches. Continuous blood pressure measurements obtained using the volume-clamp technique may be as accurate as conventional brachial noninvasive blood pressure measurements. Most importantly, clinical comparative effectiveness studies are still needed in order to determine if these technologies can be translated into improvement of relevant patient outcomes.
引用
收藏
页码:1313 / 1328
页数:16
相关论文
共 50 条
  • [11] The analysis of transesophageal oxygen saturation photoplethysmography from different signal sources
    Ling Mou
    Quan Gong
    Wei Wei
    Bo Gao
    Journal of Clinical Monitoring and Computing, 2013, 27 : 365 - 370
  • [12] THE RELATIONSHIP OF THE ARTERIAL OXYGEN SATURATION TO CYANOSIS
    GERACI, JE
    WOOD, EH
    MEDICAL CLINICS OF NORTH AMERICA, 1951, (NMAYO) : 1185 - 1202
  • [13] Misunderstanding the arterial blood oxygen saturation
    Smargiassi, Andrea
    Andreani, Mariarita
    Montebelli, Maria Rita
    Pistelli, Riccardo
    BREATHE, 2013, 9 (03) : 225 - 230
  • [14] Oxygen saturation of the arterial blood in epilepsy
    Lennox, WG
    Gibbs, EL
    ARCHIVES OF NEUROLOGY AND PSYCHIATRY, 1936, 35 (06): : 1198 - 1202
  • [15] The arterial oxygen saturation - A clinical investigation
    Bluhm, IL
    ACTA MEDICA SCANDINAVICA, 1942, 110 : 282 - 321
  • [16] NEONATAL CYANOSIS AND ARTERIAL OXYGEN SATURATION
    GOLDMAN, HI
    MARALIT, A
    SUN, S
    LANZKOWSY, P
    JOURNAL OF PEDIATRICS, 1973, 82 (02): : 319 - 324
  • [17] POLYCYTHEMIA VERA AND ARTERIAL OXYGEN SATURATION
    BADER, RA
    BADER, ME
    DUBERSTE.JL
    AMERICAN JOURNAL OF MEDICINE, 1963, 34 (04): : 435 - &
  • [18] Accurate Detection of Heart Rate and Blood Oxygen Saturation in Reflective Photoplethysmography
    Krizea, Maria
    Gialelis, John
    Kladas, Anastasios
    Theodorou, Gerasimos
    Protopsaltis, Grigoris
    Koubias, Stavros
    2020 IEEE INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND INFORMATION TECHNOLOGY (ISSPIT 2020), 2020,
  • [19] Determination of Oxygen Saturation Based on Distorted Photoplethysmography Signals by Scaling Method
    Naguszewski, Adam
    Weremczuk, Jerzy
    2018 XV INTERNATIONAL SCIENTIFIC CONFERENCE ON OPTOELECTRONIC AND ELECTRONIC SENSORS (COE), 2018,
  • [20] Investigation of photoplethysmography and arterial blood oxygen saturation from the ear-canal and the finger under conditions of artificially induced hypothermia
    Budidha, K.
    Kyriacou, P. A.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 7954 - 7957