Advances in photoplethysmography: beyond arterial oxygen saturation

被引:0
|
作者
Bartels, Karsten [1 ,2 ]
Thiele, Robert H. [3 ,4 ,5 ,6 ]
机构
[1] Univ Colorado Denver, Dept Anesthesiol, Aurora, CO USA
[2] Univ Colorado Denver, Dept Surg, Aurora, CO USA
[3] Univ Virginia, Sch Med, Dept Anesthesiol, Div Cardiac, Charlottesville, VA 22908 USA
[4] Univ Virginia, Sch Med, Dept Anesthesiol, Div Thorac, Charlottesville, VA 22908 USA
[5] Univ Virginia, Sch Med, Dept Anesthesiol, Div Crit Care Anesthesiol, Charlottesville, VA 22908 USA
[6] Univ Virginia, Sch Med, Dept Biomed Engn, Charlottesville, VA 22908 USA
关键词
PLETH VARIABILITY INDEX; PREDICT FLUID RESPONSIVENESS; WAVE-FORM AMPLITUDE; MECHANICALLY VENTILATED PATIENTS; CONTINUOUS CARDIAC-OUTPUT; SYSTOLIC BLOOD-PRESSURE; RANDOMIZED CONTROLLED-TRIAL; CRITICALLY-ILL PATIENTS; STROKE VOLUME VARIATION; PULSE TRANSIT-TIME;
D O I
10.1007/s12630-015-0458-0
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose Photoplethysmography permits continuous measurement of heart rate and peripheral oxygen saturation and has been widely used to inform clinical decisions. Recently, a myriad of noninvasive hemodynamic monitoring devices using this same technology have been increasingly available. This narrative review aims to summarize the principles that form the basis for the function of these devices as well as to comment on trials evaluating their accuracy and clinical application. Principal findings Advanced monitoring devices extend photoplethysmography technology beyond measuring oxygen concentration and heart rate. Quantification of respiratory variation of the photoplethysmographic waveform reflects respiratory variation of the arterial pressure waveform and can be used to gauge volume responsiveness. Both the volume-clamp and physiocal techniques are extensions of conventional photoplethysmography and permit continuous measurement of finger arterial blood pressure. Finger arterial pressure waveforms can subsequently inform estimations of cardiac output. Conclusions Although respiratory variations of the plethysmographic waveform correlate only modestly with the arterial blood pressure waveform, fluid responsiveness can be relatively consistently assessed using both approaches. Continuous blood pressure measurements obtained using the volume-clamp technique may be as accurate as conventional brachial noninvasive blood pressure measurements. Most importantly, clinical comparative effectiveness studies are still needed in order to determine if these technologies can be translated into improvement of relevant patient outcomes.
引用
收藏
页码:1313 / 1328
页数:16
相关论文
共 50 条
  • [31] AMBULATORY MONITORING OF ARTERIAL OXYGEN-SATURATION
    DECKER, MJ
    HOEKJE, PL
    STROHL, KP
    CHEST, 1989, 95 (04) : 717 - 722
  • [32] ERRONEOUS MEASUREMENT OF ARTERIAL OXYGEN-SATURATION
    NACHMAN, JA
    SCHWARTZ, RE
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 1993, 29 (05) : 396 - 397
  • [33] Acute mountain sickness and arterial oxygen saturation
    Schobersberger, Wolfgang
    Burtscher, Martin
    Leichtfried, Veronika
    SLEEP AND BREATHING, 2016, 20 (03) : 1077 - 1078
  • [34] PHOTOELECTRIC DETERMINATION OF ARTERIAL OXYGEN SATURATION IN MAN
    WOOD, EH
    GERACI, JE
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1949, 34 (03): : 387 - 401
  • [35] RESPIRATORY INFORMATION IN ARTERIAL OXYGEN SATURATION MEASUREMENT
    Lin, Yue-Der
    BIOSIGNALS 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIO-INSPIRED SYSTEMS AND SIGNAL PROCESSING, 2010, : 168 - 173
  • [36] Estimation of arterial oxygen saturation in relation to altitude
    Lorente-Aznar, Teofilo
    Perez-Aguilar, Guillermo
    Garcia-Espotb, Alma
    Benabarre-Ciria, Sergio
    Luis Mendia-Gprostidi, Juan
    Dols-Alonso, Daniel
    Blasco-Romero, Julia
    MEDICINA CLINICA, 2016, 147 (10): : 435 - 440
  • [37] Acute mountain sickness and arterial oxygen saturation
    Wolfgang Schobersberger
    Martin Burtscher
    Veronika Leichtfried
    Sleep and Breathing, 2016, 20 : 1077 - 1078
  • [38] CIRRHOSIS OF LIVER AND DECREASED ARTERIAL OXYGEN SATURATION
    ABELMANN, WH
    KRAMER, GE
    GRAVALLESE, MA
    VERSTRAETEN, JM
    MCNEELY, WF
    ARCHIVES OF INTERNAL MEDICINE, 1961, 108 (01) : 34 - &
  • [39] New Method of Measuring Arterial Oxygen Saturation
    Li Gang
    Bao Lei
    Zhou Mei
    Lin Ling
    Liu Rui
    Zhao Chun-jie
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (01) : 196 - 200
  • [40] RELATION OF PULMONARY VENTILATION TO ARTERIAL OXYGEN SATURATION
    HOUSTON, CS
    FEDERATION PROCEEDINGS, 1946, 5 (01) : 50 - 50