CCRI supplementary comparison of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels

被引:4
|
作者
Burns, D. T.
Allisy-Roberts, P. J.
Desrosiers, M. F.
Nagy, V. Yu.
Sharpe, P. H. G.
Laitano, R. F.
Mehta, K.
Schneider, M. K. H.
Zhang, Y. L.
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Natl Inst Stand & Technol, Gaithersburg, MD 20899 USA
[3] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[4] Ist Nazl Metrol Radiaz Ionizzanti, Rome, Italy
[5] IAEA, A-1400 Vienna, Austria
[6] Phys Tech Bundesanstalt, D-3300 Braunschweig, Germany
[7] Natl Inst Metrol, Beijing, Peoples R China
关键词
D O I
10.1016/j.radphyschem.2006.02.003
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Six national standards for absorbed dose to water in Co-60 gamma. radiation at the dose levels used in radiation processing have been compared over the range from 5 to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimeters. The standards are in agreement at the level of around 0.5%, which is significantly smaller than the stated standard uncertainties. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1087 / 1092
页数:6
相关论文
共 50 条
  • [21] Comparison of the standards for absorbed dose to water of the NPL, United Kingdom and the BIPM for 60Co γ rays
    Kessler, C.
    Allisy, P. J.
    Burns, D. T.
    Duane, S.
    Manning, J.
    [J]. METROLOGIA, 2012, 49
  • [22] Comparison of the standards for absorbed dose to water of the NPL, United Kingdom and the BIPM for 60Co γ rays
    Kessler, C.
    Burns, D. T.
    Kelly, M.
    Maughan, D. J.
    Bass, G. A.
    Shipley, D. R.
    Sander, T.
    Lee, N. D.
    Cashmore, M.
    Duane, S.
    [J]. METROLOGIA, 2019, 56 (1A)
  • [23] Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the KRISS, Republic of Korea and the BIPM in 60Co gamma radiation
    Kessler C.
    Burns D.
    Kim I.J.
    Seong Y.M.
    Yi C.-Y.
    [J]. Metrologia, 2022, 59 (1 A)
  • [24] Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60Co γ rays
    Kessler, C.
    Allisy-Roberts, P. J.
    Burns, D. T.
    Guerra, A. S.
    Laitano, R. F.
    Pimpinella, M.
    [J]. METROLOGIA, 2010, 47
  • [25] Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the LNE-LNHB, France and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Delaunay, F.
    Donois, M.
    [J]. METROLOGIA, 2013, 50
  • [26] Comparisons of air kerma and absorbed dose to water standards in Co-60 radiation beams for radiotherapy
    Kottler, Christian
    Steurer, Andreas
    Delaunay, Frank
    de Pooter, Jacco
    Mulas, Cristina Garcia
    Mihailescu, Liviu-Cristian
    [J]. METROLOGIA, 2020, 57 (1A)
  • [27] Comparison of the standards for air kerma of the VNIIM and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Oborin, A. V.
    Villevalde, A. Y.
    [J]. METROLOGIA, 2011, 48
  • [28] Comparison of the standards for air kerma of the KRISS and the BIPM for 60Co gamma radiation
    Kessler, C.
    Yi, Chul-Young
    Chung, Jae-Pil
    Roger, P.
    Allisy-Roberts, P. J.
    [J]. METROLOGIA, 2010, 47
  • [29] Comparison of the standards for air kerma of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    Ross, C. K.
    [J]. METROLOGIA, 2010, 47
  • [30] Comparison of the standards for air kerma of the BEV and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Baumgartner, A.
    Tiefenboeck, W.
    Gabris, F.