Comparison of the standards for absorbed dose to water of the NPL, United Kingdom and the BIPM for 60Co γ rays

被引:0
|
作者
Kessler, C. [1 ]
Allisy, P. J. [1 ]
Burns, D. T. [1 ]
Duane, S. [2 ]
Manning, J. [2 ]
机构
[1] Bur Int Poids & Mesures, F-92310 Sevres, France
[2] Natl Phys Lab, Teddington TW11 0LW, Middx, England
关键词
PHOTON BEAMS;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison of the standards for absorbed dose to water of the National Physical Laboratory (NPL), United Kingdom and of the Bureau International des Poids et Mesures (BIPM) has been made in Co-60 gamma radiation under the auspices of the key comparison BIPM.RI(I)-K4. The comparison result, based on the calibration coefficients for two transfer standards and expressed as a ratio of the NPL and the BIPM standards for absorbed dose to water, is 0.9980 (0.0064). The degrees of equivalence for the NPL and the other participants in this comparison have been calculated and the results are given in the form of a table for the eleven national metrology institutes (NMIs) that have taken part in the ongoing comparison for absorbed dose to water. A graphical presentation is also given.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Comparison of the standards for absorbed dose to water of the NPL, United Kingdom and the BIPM for 60Co γ rays
    Kessler, C.
    Burns, D. T.
    Kelly, M.
    Maughan, D. J.
    Bass, G. A.
    Shipley, D. R.
    Sander, T.
    Lee, N. D.
    Cashmore, M.
    Duane, S.
    [J]. METROLOGIA, 2019, 56 (1A)
  • [2] Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in 60Co γ rays
    Allisy-Roberts, P. J.
    Kessler, C.
    Burns, D. T.
    Berlyand, V.
    Berlyand, A.
    [J]. METROLOGIA, 2010, 47
  • [3] Comparison of the standards for absorbed dose to water of the VSL, The Netherlands, and the BIPM for 60Co γ rays
    Kessler, C.
    Burns, D.
    Jansen, B. J.
    de Pooter, J. A.
    de Prez, L. A.
    [J]. METROLOGIA, 2018, 55
  • [4] Comparison of the standards for air kerma of the NPL and the BIPM for 60Co γ rays
    Kessler, C.
    Allisy, P. J.
    Burns, D. T.
    Duane, S.
    Manning, J.
    Nutbrown, R.
    [J]. METROLOGIA, 2010, 47
  • [5] Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60Co γ rays
    Kessler, C.
    Allisy-Roberts, P. J.
    Burns, D. T.
    Guerra, A. S.
    Laitano, R. F.
    Pimpinella, M.
    [J]. METROLOGIA, 2010, 47
  • [6] Comparison of the standards for absorbed dose to water of the NMIJ and the BIPM for 60Co γ-ray beams
    Kessler, C.
    Allisy-Roberts, P. J.
    Morishita, Y.
    Kato, M.
    Takata, N.
    Kurosawa, T.
    Tanaka, T.
    Saito, N.
    [J]. METROLOGIA, 2011, 48
  • [7] Comparison of the standards for absorbed dose to water of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    McEwen, M. R.
    Ross, C. K.
    [J]. METROLOGIA, 2010, 47
  • [8] Comparison of the standards for absorbed dose to water of the ARPANSA and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    Butler, D.
    Lye, J.
    Webb, D.
    [J]. METROLOGIA, 2012, 49
  • [9] Comparison of the standards for absorbed dose to water of the BEV, Austria, and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Tiefenboeck, W.
    Gabris, F.
    [J]. METROLOGIA, 2010, 47
  • [10] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NPL, United Kingdom and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Kelly, M.
    Maughan, D. J.
    Bass, G. A.
    Homer, M. J.
    [J]. METROLOGIA, 2019, 56 (1A)