Comparison of the standards for absorbed dose to water of the BEV, Austria, and the BIPM for 60Co gamma radiation

被引:5
|
作者
Kessler, C. [1 ]
Allisy-Roberts, P. J. [1 ]
Steurer, A. [2 ]
Tiefenboeck, W. [2 ]
Gabris, F. [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Bundesamt Eich & Vermessungswesen, A-1160 Vienna, Austria
关键词
AIR KERMA; RAYS; CS-137;
D O I
10.1088/0026-1394/47/1A/06017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A direct comparison of the standards for air kerma of the Bundesamt fur Eich- und Vermessungswesen (BEV), Austria, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the Cs-137 radiation beam of the BIPM in March 2009. The result, expressed as ratios of the BEV and the BIPM standards for air kerma, is 1.0041 with a combined standard uncertainty of 3.1 x 10(-3). The result of the earlier direct comparison in 137Cs. rays, made in 1995, was 0.9961(28); taking into account the changes made recently to both standards, the 1995 result becomes 1.0035 (24), in agreement with the present comparison result.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Comparison of the standards for absorbed dose to water of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    McEwen, M. R.
    Ross, C. K.
    [J]. METROLOGIA, 2010, 47
  • [2] Comparison of the standards for absorbed dose to water of the ARPANSA and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    Butler, D.
    Lye, J.
    Webb, D.
    [J]. METROLOGIA, 2012, 49
  • [3] Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the BEV, Austria and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Steurer, A.
    Tiefenboeck, W.
    Merza, V.
    [J]. METROLOGIA, 2021, 58 (1A)
  • [4] Comparison of the standards for air kerma of the BEV and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Baumgartner, A.
    Tiefenboeck, W.
    Gabris, F.
    [J]. METROLOGIA, 2010, 47
  • [5] Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in 60Co γ rays
    Allisy-Roberts, P. J.
    Kessler, C.
    Burns, D. T.
    Berlyand, V.
    Berlyand, A.
    [J]. METROLOGIA, 2010, 47
  • [6] Comparison of the standards for absorbed dose to water of the NMIJ and the BIPM for 60Co γ-ray beams
    Kessler, C.
    Allisy-Roberts, P. J.
    Morishita, Y.
    Kato, M.
    Takata, N.
    Kurosawa, T.
    Tanaka, T.
    Saito, N.
    [J]. METROLOGIA, 2011, 48
  • [7] Comparison of the standards for absorbed dose to water of the VSL, The Netherlands, and the BIPM for 60Co γ rays
    Kessler, C.
    Burns, D.
    Jansen, B. J.
    de Pooter, J. A.
    de Prez, L. A.
    [J]. METROLOGIA, 2018, 55
  • [8] Comparison of the standards for absorbed dose to water of the NPL, United Kingdom and the BIPM for 60Co γ rays
    Kessler, C.
    Allisy, P. J.
    Burns, D. T.
    Duane, S.
    Manning, J.
    [J]. METROLOGIA, 2012, 49
  • [9] Comparison of the standards for absorbed dose to water of the NPL, United Kingdom and the BIPM for 60Co γ rays
    Kessler, C.
    Burns, D. T.
    Kelly, M.
    Maughan, D. J.
    Bass, G. A.
    Shipley, D. R.
    Sander, T.
    Lee, N. D.
    Cashmore, M.
    Duane, S.
    [J]. METROLOGIA, 2019, 56 (1A)
  • [10] Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the ARPANSA, Australia and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D.
    Oliver, C.
    Bailey, T.
    Harty, P.
    Butler, D.
    [J]. METROLOGIA, 2021, 58 (1A)