Comparison of the standards for absorbed dose to water of the BEV, Austria, and the BIPM for 60Co gamma radiation

被引:5
|
作者
Kessler, C. [1 ]
Allisy-Roberts, P. J. [1 ]
Steurer, A. [2 ]
Tiefenboeck, W. [2 ]
Gabris, F. [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Bundesamt Eich & Vermessungswesen, A-1160 Vienna, Austria
关键词
AIR KERMA; RAYS; CS-137;
D O I
10.1088/0026-1394/47/1A/06017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A direct comparison of the standards for air kerma of the Bundesamt fur Eich- und Vermessungswesen (BEV), Austria, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the Cs-137 radiation beam of the BIPM in March 2009. The result, expressed as ratios of the BEV and the BIPM standards for air kerma, is 1.0041 with a combined standard uncertainty of 3.1 x 10(-3). The result of the earlier direct comparison in 137Cs. rays, made in 1995, was 0.9961(28); taking into account the changes made recently to both standards, the 1995 result becomes 1.0035 (24), in agreement with the present comparison result.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60Co γ rays
    Kessler, C.
    Allisy-Roberts, P. J.
    Burns, D. T.
    Guerra, A. S.
    Laitano, R. F.
    Pimpinella, M.
    [J]. METROLOGIA, 2010, 47
  • [22] Key comparison BIPM.RI(I)-K4 of the absorbed dose to water standards of the LNE-LNHB, France and the BIPM in 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Delaunay, F.
    Donois, M.
    [J]. METROLOGIA, 2013, 50
  • [23] Comparison of the standards for air kerma of the KRISS and the BIPM for 60Co gamma radiation
    Kessler, C.
    Yi, Chul-Young
    Chung, Jae-Pil
    Roger, P.
    Allisy-Roberts, P. J.
    [J]. METROLOGIA, 2010, 47
  • [24] Comparison of the standards for air kerma of the VNIIM and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Oborin, A. V.
    Villevalde, A. Y.
    [J]. METROLOGIA, 2011, 48
  • [25] Comparison of the standards for air kerma of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    Ross, C. K.
    [J]. METROLOGIA, 2010, 47
  • [26] Comparison of the standards for air kerma of the ARPANSA and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Lye, J.
    Oliver, C.
    [J]. METROLOGIA, 2011, 48
  • [27] Comparison of the standards for air kerma of the NIST and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Minniti, Ronaldo
    [J]. METROLOGIA, 2013, 50
  • [28] Comparison of the standards for air kerma of the VSL and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    de Prez, L. A.
    van Dijk, E.
    [J]. METROLOGIA, 2010, 47
  • [29] Supplementary comparison CCRI(I)-S3 of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels
    McEwen, M.R.
    Sharpe, P.H.G.
    Pazos, I.M.
    Miller, A.
    Pawlak, E.
    Ninlaphruk, S.
    Zhang, Y.
    Kessler, C.
    [J]. Metrologia, 2022, 59 (1 A)
  • [30] Supplementary comparison CCRI(I)-S2 of standards for absorbed dose to water in 60Co gamma radiation at radiation processing dose levels
    Burns, D. T.
    Allisy-Roberts, P. J.
    Desrosiers, M. F.
    Sharpe, P. H. G.
    Pimpinella, M.
    Lourenco, V.
    Zhang, Y. L.
    Miller, A.
    Generalova, V.
    Sochor, V.
    [J]. METROLOGIA, 2011, 48