Comparison of the standards for absorbed dose to water of the ENEA-INMRI (Italy) and the BIPM for 60Co γ rays

被引:8
|
作者
Kessler, C. [1 ]
Allisy-Roberts, P. J. [1 ]
Burns, D. T. [1 ]
Guerra, A. S. [2 ]
Laitano, R. F. [2 ]
Pimpinella, M. [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] ENEA CR Casaccia, Ist Nazl Metrol Radiaz Ionizzanti, I-00100 Rome, Italy
关键词
D O I
10.1088/0026-1394/47/1A/06002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison of the standards for absorbed dose to water of the Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti of the Ente per le Nuove Tecnologie, l'Energia e l'Ambiente, Italy (ENEA-INMRI), and of the Bureau International des Poids et Mesures (BIPM) has been made in Co-60 gamma radiation under the auspices of the key comparison BIPM. RI(I)-K4. The comparison result, based on the calibration coefficients for three transfer standards and expressed as a ratio of the ENEA and the BIPM standards for absorbed dose to water, is 0.9999 (0.0044). The present 2007 result replaces the earlier ENEA value in this key comparison. The degrees of equivalence between the ENEA and the other participants in this comparison have been calculated and the results are given in the form of a matrix for the ten national metrology institutes (NMIs) that have published results in this ongoing comparison for absorbed dose to water. A graphical presentation is also given.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Comparison of the standards for absorbed dose to water of the VNIIFTRI, Russia and the BIPM in 60Co γ rays
    Allisy-Roberts, P. J.
    Kessler, C.
    Burns, D. T.
    Berlyand, V.
    Berlyand, A.
    [J]. METROLOGIA, 2010, 47
  • [2] Comparison of the standards for absorbed dose to water of the VSL, The Netherlands, and the BIPM for 60Co γ rays
    Kessler, C.
    Burns, D.
    Jansen, B. J.
    de Pooter, J. A.
    de Prez, L. A.
    [J]. METROLOGIA, 2018, 55
  • [3] Comparison of the standards of air kerma of the ENEA-INMRI and the BIPM for 137Cs γ rays
    Allisy-Roberts, P. J.
    Kessler, C.
    Toni, M.
    Bovi, M.
    [J]. METROLOGIA, 2010, 47
  • [4] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the ENEA-INMRI, Italy and the BIPM in 60Co gamma radiation
    Kessler, C.
    Pinto, M.
    Cappadozzi, G.
    Silvestri, C.
    Bovi, M.
    Toni, M. P.
    [J]. METROLOGIA, 2015, 52
  • [5] Comparison of the standards for absorbed dose to water of the NPL, United Kingdom and the BIPM for 60Co γ rays
    Kessler, C.
    Allisy, P. J.
    Burns, D. T.
    Duane, S.
    Manning, J.
    [J]. METROLOGIA, 2012, 49
  • [6] Comparison of the standards for absorbed dose to water of the NPL, United Kingdom and the BIPM for 60Co γ rays
    Kessler, C.
    Burns, D. T.
    Kelly, M.
    Maughan, D. J.
    Bass, G. A.
    Shipley, D. R.
    Sander, T.
    Lee, N. D.
    Cashmore, M.
    Duane, S.
    [J]. METROLOGIA, 2019, 56 (1A)
  • [7] Comparison of the standards for absorbed dose to water of the NMIJ and the BIPM for 60Co γ-ray beams
    Kessler, C.
    Allisy-Roberts, P. J.
    Morishita, Y.
    Kato, M.
    Takata, N.
    Kurosawa, T.
    Tanaka, T.
    Saito, N.
    [J]. METROLOGIA, 2011, 48
  • [8] Comparison of the standards for absorbed dose to water of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    McEwen, M. R.
    Ross, C. K.
    [J]. METROLOGIA, 2010, 47
  • [9] Comparison of the standards for absorbed dose to water of the ARPANSA and the BIPM for 60Co gamma radiation
    Kessler, C.
    Burns, D. T.
    Allisy-Roberts, P. J.
    Butler, D.
    Lye, J.
    Webb, D.
    [J]. METROLOGIA, 2012, 49
  • [10] Comparison of the standards for absorbed dose to water of the BEV, Austria, and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Tiefenboeck, W.
    Gabris, F.
    [J]. METROLOGIA, 2010, 47