摘要
We present the concept of and the procedure for realizing the primary scale of the spectral responsivity based on an absolute cryogenic radiometer at the Korea Research Institute of Standards and Science (KRISS). A detailed error and uncertainty analysis is performed by calibrating the standard detectors in the wavelength range from 300 nm to 1000 nm. The relative expanded uncertainty of the spectral responsivity calibration for a Si trap detector is 0.06% at 632.8 nm and 0.4% for other wavelengths (k = 2). The calibration results are validated by comparing with the results from a theoretical model of quantum efficiency for a transmission-type trap detector.
引用
收藏
页码:2045 / 2058
页数:14
相关论文
共 50 条
  • [21] Infrared spectral responsivity scale realization and validations
    Eppeldauer, George P.
    Podobedov, Vyacheslav B.
    APPLIED OPTICS, 2012, 51 (25) : 6003 - 6008
  • [22] A Cryogenic Radiometry Based Spectral Responsivity Scale at the National Metrology Centre
    Xu, Gan
    Huang, Xuebo
    INTERNATIONAL CONFERENCE ON OPTICS IN PRECISION ENGINEERING AND NANOTECHNOLOGY (ICOPEN 2011), 2011, 19
  • [23] Total and spectral radiance measurements of blackbody radiation sources based on an absolute cryogenic radiometer
    Gan, Haiyong
    Xu, Nan
    Liu, Xiangliang
    He, Yingwei
    Wu, Houping
    Feng, Guojin
    Liu, Wende
    Lin, Yandong
    AOPC 2019: OPTICAL SENSING AND IMAGING TECHNOLOGY, 2019, 11338
  • [24] Space Cryogenic Absolute Radiometer
    Wu D.
    Wang K.
    Ye X.
    Wang Y.-P.
    Fang W.
    Faguang Xuebao/Chinese Journal of Luminescence, 2019, 40 (08): : 1015 - 1021
  • [25] Experimental Study on Traceability of Absolute Radiometer to Cryogenic Radiometer
    Zhang Junchao
    Xu Nan
    Xu Ning
    Meng Haifeng
    Liu Wende
    Cai Chuan
    Zhang Bifeng
    Man Shuai
    Wang Meng
    Li Yinliang
    Xiong Limin
    ACTA OPTICA SINICA, 2022, 42 (05)
  • [26] Prototype of Cryogenic Solar Absolute Radiometer and Transfer Radiometer for On-Board Calibration of Spectral Earth Imager
    Zajiczek, L.
    Winkler, R.
    Hobson, T.
    Green, P.
    Fox, N.
    13TH INTERNATIONAL CONFERENCE ON NEW DEVELOPMENTS AND APPLICATIONS IN OPTICAL RADIOMETRY, 2018, 972
  • [27] A CRYOGENIC RADIOMETER FOR ABSOLUTE RADIOMETRIC MEASUREMENTS
    MARTIN, JE
    FOX, NP
    KEY, PJ
    METROLOGIA, 1985, 21 (03) : 147 - 155
  • [28] CRYOGENIC SOLAR ABSOLUTE RADIOMETER (CSAR)
    MARTIN, JE
    FOX, NP
    METROLOGIA, 1993, 30 (04) : 305 - 308
  • [29] A New Spectral Responsivity Calibration Comparator of InGaAs photodiode Based on Cryogenic Radiometer Fundamental at the National Institute of Metrology of China
    He, Yingwei
    Gan, Haiyong
    Liu, Wende
    Lin, Yongjie
    Wang, Yangyang
    Xu, Ning
    Zhao, Weidiang
    Liu, Zhiwei
    Xiong, Limin
    Xu, Nan
    Lin, Yandong
    OPTICAL METROLOGY AND INSPECTION FOR INDUSTRIAL APPLICATIONS VII, 2020, 11552
  • [30] Realization of a spectral radiance responsivity scale with a laser-based source and Si radiance meters
    Eppeldauer, GP
    Brown, SW
    Larason, TC
    Rácz, M
    Lykke, KR
    METROLOGIA, 2000, 37 (05) : 531 - 534