A pilot study of pharyngeal pulse oximetry with the laryngeal mask airway:: A comparison with finger oximetry and arterial saturation measurements in healthy anesthetized patients

被引:11
|
作者
Keller, C
Brimacombe, J
Agrò, F
Margreiter, J
机构
[1] Leopold Franzens Univ Innsbruck, Dept Anaesthesia & Intens Care Med, Innsbruck, Austria
[2] Univ Queensland, Cairns Base Hosp, Dept Anaesthesia & Intens Care, Cairns, Australia
[3] Univ Sch Med LIU, Dept Anaesthesia, Rome, Italy
来源
ANESTHESIA AND ANALGESIA | 2000年 / 90卷 / 02期
关键词
D O I
10.1097/00000539-200002000-00037
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We compared pharyngeal Spo(2) by using the laryngeal mask airway (LMA) to finger Spo(2) and oxygen saturation from arterial blood samples (Sao(2)). We studied 20 hemodynamically stable, well oxygenated, anesthetized patients (ASA physical status I-III, aged 18-80 yr). A single-use pediatric pulse oximeter was attached to the back plate of a size 5 LMA. Pharyngeal and finger Spo(2) (dominant index finger) and Sao(2) (nondominant radial artery) were measured with the cuff volume at 0-40 mL in the neutral position. The intracuff pressure was then set at 60 cm H2O in the neutral position, and readings were taken with the head-neck flexed, extended, and rotated. Sao(2) was the same as pharyngeal Spo(2) at 20 and 30 mL cuff volume, but higher than pharyngeal Spo(2) at all other cuff volumes and head-neck positions (P < 0.04). Sao(2) was always higher than finger Spo(2) (P < 0.01). Pharyngeal Spo(2) was higher than finger Spo(2) at cuff volumes 10-40 mL and in the flexed and rotated head-neck positions (all: P < 0.007), but was lower at 0 cuff volume (P < 0.0001) and similar in the extended head-neck position. There was an increase in pharyngeal Spo(2) between 0 and 10 mL cuff volume (P < 0.0001), but no changes thereafter. Pharyngeal Spo(2) was similar in the flexed, rotated and extended head-neck positions. Pharyngeal Spo(2) agrees more closely with Sao(2) (mean difference < 0.7%) than finger Spo(2) (mean difference > 1.1%) at 10-40 mL cuff volume and in head-neck flexion. The standard error of limits was identical (0.09) for both finger Spo(2) and pharyngeal Spo(2) if data at 0 cuff volume are excluded. We conclude that pharyngeal Spo(2) with the LMA is feasible and generally provides more accurate readings than finger Spo(2), in hemodynamically stable, well oxygenated, anesthetized patients. Implications: Pharyngeal oximetry with the laryngeal mask airway is feasible and generally provides more accurate readings than finger oximetry in hemodynamically stable, well oxygenated, anesthetized patients.
引用
收藏
页码:440 / 444
页数:5
相关论文
共 50 条
  • [21] Differences Between Pulse Oximetry Readings from Finger vs. Ear Probe Locations in Anesthetized Patients
    Date, Preshita
    Samayoa, Gabriela
    Nayaz, Sakina
    Dennis, Jeremy
    Esquenazi, Jacob
    Stohl, Malka
    Goldstein, Sheldon
    ANESTHESIA AND ANALGESIA, 2022, 134 : 1178 - 1179
  • [22] Influence of digital clubbing on oxygen saturation measurements by pulse-oximetry in cystic fibrosis patients
    Van Ginderdeuren, Filip
    Van Cauwelaert, Karlien
    Malfroot, Anne
    JOURNAL OF CYSTIC FIBROSIS, 2006, 5 (02) : 125 - 128
  • [23] A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients
    Ebmeier, S. J.
    Barker, M.
    Bacon, M.
    Beasley, R. C.
    Bellomo, R.
    Chong, C. Knee
    Eastwood, G. M.
    Gilchrist, J.
    Kagaya, H.
    Pilcher, J.
    Reddy, S. K.
    Ridgeon, E.
    Sarma, N.
    Spragas, S.
    Tanaka, A.
    Tweedie, M.
    Weatherall, M.
    Young, P. J.
    ANAESTHESIA AND INTENSIVE CARE, 2018, 46 (03) : 297 - 303
  • [24] Pulse Oximetry and Arterial Saturation Difference in Pediatric COVID-19 Patients: Retrospective Analysis by Race*
    Savorgnan, Fabio
    Hassan, Adel
    Borges, Nirica
    Acosta, Sebastian
    PEDIATRIC CRITICAL CARE MEDICINE, 2023, 24 (06) : 458 - 462
  • [25] Comparative analysis of the arterial oxygen saturation (SaO2) and pulse oximetry measurements (SpO2) in patients with pulmonary tuberculosis
    Chushkin, Mikhail
    Popova, Lydia
    Shergina, Elena
    Krasnikova, Elena
    Gordeeva, Olga
    Karpina, Natalya
    EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [26] STUDY ON PULSE OXIMETRY OXYGEN SATURATION LEVEL AND PARTIAL PRESSURE OF OXYGEN IN ARTERIAL BLOOD IN HOSPITALIZED NEONATE
    Das, J. C.
    Shahidullah, M.
    Khanam, S. T.
    Hafez, M. A.
    INTENSIVE CARE MEDICINE, 2013, 39 : S135 - S136
  • [27] The laryngeal mask airway Unique™ versus the Soft Seal™ laryngeal mask:: A randomized, crossover study in paralyzed, anesthetized patients
    Brimacombe, J
    von Goedecke, A
    Keller, C
    Brimacombe, L
    Brimacombe, M
    ANESTHESIA AND ANALGESIA, 2004, 99 (05): : 1560 - 1563
  • [28] A Comparison of Oxygen Saturation in White-tailed Deer Estimated by Pulse Oximetry and from Arterial Blood Gases
    Muller, Lisa I.
    Osborn, David A.
    Doherty, Tom
    Keel, M. Kevin
    Miller, Brad F.
    Warren, Robert J.
    Miller, Karl V.
    JOURNAL OF WILDLIFE DISEASES, 2012, 48 (02) : 458 - 461
  • [29] OXYGEN-SATURATION MONITORING IN EXPERIMENTAL SURGERY - A COMPARISON OF PULSE OXIMETRY AND ARTERIAL BLOOD-GAS MEASUREMENT
    VENDER, JR
    HAND, CM
    SEDOR, D
    TABOR, SL
    BLACK, P
    LABORATORY ANIMAL SCIENCE, 1995, 45 (02): : 211 - 215
  • [30] Intubation using laryngeal mask airway CTrach and laryngeal mask airway Fastrach in anesthetized non-paralyzed patients: a randomized controlled study
    Ola T. Abdel Dayem
    Tamer M. Farahat
    Ain-Shams Journal of Anesthesiology, 11