A novel method for sensitive, low-cost and portable detection of hepatitis B surface antigen using a personal glucose meter

被引:24
|
作者
Taebi, Saeed [1 ]
Keyhanfar, Mehrnaz [1 ]
Noorbakhsh, Abdollah [2 ]
机构
[1] Univ Isfahan, Fac Adv Sci & Technol, Dept Biotechnol, Esfahan 8174673441, Iran
[2] Univ Isfahan, Dept Nanotechnol Engn, Fac Adv Sci & Technol, Esfahan 8174673441, Iran
关键词
Hepatitis B; Hepatitis B surface antigen; Personal glucose meter; Nanoparticle; GOLD NANOPARTICLES; ELECTROCHEMICAL DETECTION; ASSAY; IMMUNOASSAY; ANTIBODY; ENZYME; IMMUNOSENSOR; GLUCOAMYLASE; ENHANCEMENT; MEMBRANE;
D O I
10.1016/j.jim.2018.04.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hepatitis B virus (HBV) infection is the major public health problem leading cause of death worldwide. The most important diagnostic marker for this infection is hepatitis B surface antigen (HBsAg). In this study, a novel, inexpensive, portable and sensitive ELISA method was designed and investigated for diagnosis of HBsAg based on the functionalized Fe3O4 and Al2O3 nanoparticles, with the strategy for detecting the concentration of glucose using a cheap and accessible personal glucose meter (PGM). The ELISA system was constructed using hepatitis B antibody against HBsAg immobilized on streptavidin coated magnetic iron oxide particles (S-Fe3O4) as the capture antibody (Ab(1)). In addition, another hepatitis B antibody against different epitope of HBsAg (Ab(2)) and glucoamylase both were immobilized on Al2O3 nanoparticles. After formation of the sandwich immune complex between Ab(1) and Ab(2) immobilized on S-Fe3O4 and Al2O3 NPs, respectively, through HBsAg, starch was converted into glucose using glucoamylase. Then, the glucose concentration was measured using PGM. The concentration of HBsAg was calculated based on the linear relation between the concentrations of HBsAg and glucose. Under optimal conditions, this assay showed detection limit values of 0.3 to 0.4 ng ml(-1) for "ay" and "ad" subtypes of HBsAg, respectively. The results indicate that the designed assay is comparable to the commercial kits in terms of sensitivity, on-site, specificity, cost, simplicity, portability and reproducibility. The presented method can be used in disadvantaged areas of the world and blood transfusion centers. To the best of our knowledge, this is the first report of using PGMs for HBSAg detection.
引用
收藏
页码:26 / 32
页数:7
相关论文
共 50 条
  • [31] Highly sensitive detection of M.SssI DNA methyltransferase activity using a personal glucose meter
    Deng, Huimin
    Peng, Si Ying
    Gao, Zhiqiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (21) : 5867 - 5872
  • [32] CRISPR-Cas12a-driven aptasensor for sensitive detection of alternariol by using a personal glucose meter
    Yang, Ruiqi
    Zhao, Liping
    Fang, Mengqi
    Kong, Weijun
    Luan, Yunxia
    TALANTA, 2025, 286
  • [33] Detection of hepatitis B surface antigen by immunoassay using magnetite nanoparticles binding hepatitis B surface antibody
    Bui Trung Thanh
    Tran Hoang Hai
    Pham Hung Van
    Le Minh Tung
    Lee, Jaeryeong
    GEOSYSTEM ENGINEERING, 2019, 22 (04) : 206 - 213
  • [34] A Novel Phase Loss Detection Method for Low-Cost Motor Drives
    Dianov, Anton
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (06) : 6660 - 6668
  • [35] Low-cost portable system prototype for breast cancer detection using UWB signals
    Aragao, Alexandre de Jesus
    Sanches, Bruno
    de Carvalho, Dionisio
    Van Noije, Wilhelmus A. M.
    2020 13TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2020), 2020, : 715 - 720
  • [36] Portable Low-Cost Heart Attack Detection System Using ZigBee Wireless Technology
    Ahmed, Khaled Sayed
    El-Metwally, Shereen M.
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING (IWBBIO 2015), PT I, 2015, 9043 : 155 - 162
  • [37] A portable and efficient strategy for ofloxacin detection using Ce-based MOF-loaded glucose oxidase and a personal glucose meter
    Wang, Qianqian
    He, Baoshan
    Liu, Yao
    Wu, Ligen
    Zhao, Wenhong
    Xie, Dongdong
    Ren, Wenjie
    Xu, Yiwei
    ANALYTICA CHIMICA ACTA, 2025, 1351
  • [38] ASPRIA - NEW SENSITIVE ASSAY FOR THE DETECTION OF HEPATITIS-B SURFACE-ANTIGEN
    MILLMAN, I
    SMITH, M
    JOURNAL OF IMMUNOLOGICAL METHODS, 1979, 31 (3-4) : 365 - 371
  • [39] Portable Detection of Melamine in Milk Using a Personal Glucose Meter Based on an in Vitro Selected Structure-Switching Aptamer
    Gu, Chunmei
    Lan, Tian
    Shi, Hanchang
    Lu, Yi
    ANALYTICAL CHEMISTRY, 2015, 87 (15) : 7676 - 7682
  • [40] Phase-sensitive detection in the undergraduate lab using a low-cost microcontroller
    Schultz, K. D.
    AMERICAN JOURNAL OF PHYSICS, 2016, 84 (07) : 557 - 561