Portable Detection of Melamine in Milk Using a Personal Glucose Meter Based on an in Vitro Selected Structure-Switching Aptamer

被引:129
|
作者
Gu, Chunmei [1 ,2 ]
Lan, Tian [2 ]
Shi, Hanchang [1 ]
Lu, Yi [2 ,3 ]
机构
[1] Tsinghua Univ, Sch Environm, State Key Joint Lab ESPC, Beijing 100084, Peoples R China
[2] Univ Illinois, Dept Biochem, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
基金
美国国家科学基金会;
关键词
CAPILLARY-ZONE-ELECTROPHORESIS; MASS-SPECTROMETRIC DETECTION; POINT-OF-CARE; EXPONENTIAL ENRICHMENT; QUANTITATIVE DETECTION; SYSTEMATIC EVOLUTION; RAPID DETECTION; INFANT FORMULA; CYANURIC ACID; CELL-SELEX;
D O I
10.1021/acs.analchem.5b01085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Melamine detection in milk and other foods has attracted much attention since the discovery that melamine-adulterated food causes severe kidney damage. Although many methods have been developed to detect melamine, few methods can provide quantitative results using an affordable and portable device that is suitable for home use or field application. To achieve this goal, we herein report the first in vitro selection of a melamine responsive aptamer using a structure-switching method. A personal glucose meter (PGM) based melamine sensor was designed and subsequently tested using the newly isolated aptamer. Conversion of melamine concentration to glucose amount was achieved by including an invertase-conjugated DNA that is complementary to part of the aptamer. Melamine binding triggers the release of the invertase-DNA conjugate, which hydrolyzes sucrose into glucose. The glucose produced is then measured directly using an off-the-shelf PGM. The described sensor shows high selectivity for melamine against several closely related melamine analogues, such as cyanuric acid, ammeline, and ammelide, and has low detection limits of 0.33 mu M (or 41.1 ppb) in buffer and 0.53 mu M (or 67.5 ppb) in 80% whole milk without any pretreatment. The detection limits meet the threshold of 2.5 ppm for non-infant-formula products and 1 ppm for melamine in infant milk products as defined by the U.S. Food and Drug Administration (FDA). In addition to the PGM sensor demonstrated here, the same aptamer can be converted into other types of sensors with different signal outputs, allowing portable detection of melamine under a variety of conditions.
引用
收藏
页码:7676 / 7682
页数:7
相关论文
共 50 条
  • [1] Portable detection of Ochratoxin A based on a structure-switching aptamer using a personal glucose meter (PGM)
    Gu, Chunmei
    Shi, Hanchang
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [2] Portable detection of ochratoxin A in red wine based on a structure-switching aptamer using a personal glucometer
    Gu, Chunmei
    Long, Feng
    Zhou, Xiaohong
    Shi, Hanchang
    RSC ADVANCES, 2016, 6 (35): : 29563 - 29569
  • [3] Portable biosensor for quantitative detection of melamine based on CRISPRCas12a and a personal glucose meter
    Shi, Kai
    Sun, Guofeng
    Zhou, Yuqin
    Song, Jiuhua
    Cheng, Ying
    Yin, Hui
    He, Fanxiang
    Zhou, Yuanyuan
    Li, Na
    Shu, Qin
    Chen, Jiaxuan
    Chinese Journal of Analysis Laboratory, 2023, 42 (08): : 1088 - 1093
  • [4] Portable Detection of Copper Ion Using Personal Glucose Meter
    Du, Bin
    Chen, Taoying
    Huang, Anqi
    Chen, Haijun
    Liu, Wei
    SENSORS, 2024, 24 (21)
  • [5] Development of a structure-switching aptamer-based nanosensor for salicylic acid detection
    Chen, Changtian
    Feng, Silu
    Zhou, Mian
    Ji, Chonghui
    Que, Long
    Wang, Wei
    BIOSENSORS & BIOELECTRONICS, 2019, 140 : 40 - 47
  • [6] An aptasensor for the detection of ampicillin in milk using a personal glucose meter
    Li, Fang
    Li, Xixi
    Zhu, Nanwei
    Li, Ruohan
    Kang, Huaibin
    Zhang, Qinpu
    ANALYTICAL METHODS, 2020, 12 (26) : 3376 - 3381
  • [7] Detection of adenosine using surface-enhanced Raman scattering based on structure-switching signaling aptamer
    Chen, Ji-Wei
    Liu, Xue-Ping
    Feng, Ke-Jun
    Liang, Yi
    Jiang, Jian-Hui
    Shen, Guo-Li
    Yu, Ru-Qin
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (01): : 66 - 71
  • [8] Multiplexed Detection of Small Analytes by Structure-Switching Aptamer-Based Capillary Electrophoresis
    Zhu, Zhenyu
    Ravelet, Corinne
    Perrier, Sandrine
    Guieu, Valerie
    Roy, Beatrice
    Perigaud, Christian
    Peyrin, Eric
    ANALYTICAL CHEMISTRY, 2010, 82 (11) : 4613 - 4620
  • [9] Facile method for enrofloxacin detection in milk using a personal glucose meter
    Kwon, Donghoon
    Lee, Hyeonjeong
    Yoo, Hojin
    Hwang, Jeongin
    Lee, Dongkyu
    Jeon, Sangmin
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 254 : 935 - 939
  • [10] Label-free fluorescence probe based on structure-switching aptamer for the detection of interferon gamma
    Pan, Li
    Huang, Yong
    Wen, Changchun
    Zhao, Shulin
    ANALYST, 2013, 138 (22) : 6811 - 6816