Portable Detection of Melamine in Milk Using a Personal Glucose Meter Based on an in Vitro Selected Structure-Switching Aptamer

被引:129
|
作者
Gu, Chunmei [1 ,2 ]
Lan, Tian [2 ]
Shi, Hanchang [1 ]
Lu, Yi [2 ,3 ]
机构
[1] Tsinghua Univ, Sch Environm, State Key Joint Lab ESPC, Beijing 100084, Peoples R China
[2] Univ Illinois, Dept Biochem, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
基金
美国国家科学基金会;
关键词
CAPILLARY-ZONE-ELECTROPHORESIS; MASS-SPECTROMETRIC DETECTION; POINT-OF-CARE; EXPONENTIAL ENRICHMENT; QUANTITATIVE DETECTION; SYSTEMATIC EVOLUTION; RAPID DETECTION; INFANT FORMULA; CYANURIC ACID; CELL-SELEX;
D O I
10.1021/acs.analchem.5b01085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Melamine detection in milk and other foods has attracted much attention since the discovery that melamine-adulterated food causes severe kidney damage. Although many methods have been developed to detect melamine, few methods can provide quantitative results using an affordable and portable device that is suitable for home use or field application. To achieve this goal, we herein report the first in vitro selection of a melamine responsive aptamer using a structure-switching method. A personal glucose meter (PGM) based melamine sensor was designed and subsequently tested using the newly isolated aptamer. Conversion of melamine concentration to glucose amount was achieved by including an invertase-conjugated DNA that is complementary to part of the aptamer. Melamine binding triggers the release of the invertase-DNA conjugate, which hydrolyzes sucrose into glucose. The glucose produced is then measured directly using an off-the-shelf PGM. The described sensor shows high selectivity for melamine against several closely related melamine analogues, such as cyanuric acid, ammeline, and ammelide, and has low detection limits of 0.33 mu M (or 41.1 ppb) in buffer and 0.53 mu M (or 67.5 ppb) in 80% whole milk without any pretreatment. The detection limits meet the threshold of 2.5 ppm for non-infant-formula products and 1 ppm for melamine in infant milk products as defined by the U.S. Food and Drug Administration (FDA). In addition to the PGM sensor demonstrated here, the same aptamer can be converted into other types of sensors with different signal outputs, allowing portable detection of melamine under a variety of conditions.
引用
收藏
页码:7676 / 7682
页数:7
相关论文
共 50 条
  • [31] Structure-switching aptamer triggering signal amplification strategy for tobramycin detection based on hybridization chain reaction and fluorescence synergism
    Wang, Junyang
    Li, Hongxia
    Du, Caiyi
    Li, Ying
    Ma, Xinyue
    Yang, Chuanyu
    Xu, Wentao
    Sun, Chunyan
    TALANTA, 2022, 243
  • [32] Electrochemical detection of cortisol using a structure-switching aptamer immobilized on gold nanoparticles-modified screen-printed electrodes
    Vipasha Sharma
    Tarun Kumar Sharma
    Inderpreet Kaur
    Journal of Applied Electrochemistry, 2023, 53 : 1765 - 1776
  • [33] A gold nanoparticles-modified aptamer beacon for urinary adenosine detection based on structure-switching/fluorescence-"turning on" mechanism
    Zhang, Jin-Quan
    Wang, Yong-Sheng
    Xue, Jin-Hua
    He, Yan
    Yang, Hui-Xian
    Liang, Jun
    Shi, Lin-Fei
    Xiao, Xi-Lin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 70 : 362 - 368
  • [34] Electrochemical detection of cortisol using a structure-switching aptamer immobilized on gold nanoparticles-modified screen-printed electrodes
    Sharma, Vipasha
    Sharma, Tarun Kumar
    Kaur, Inderpreet
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2023, 53 (09) : 1765 - 1776
  • [35] A solid-state electrochemiluminescence sensing platform for detection of adenosine based on ferrocene-labeled structure-switching signaling aptamer
    Wang, Xiaoying
    Dong, Ping
    He, Pingang
    Fang, Yuzhi
    ANALYTICA CHIMICA ACTA, 2010, 658 (02) : 128 - 132
  • [36] A signal-on fluorescent aptasensor based on Tb3+ and structure-switching aptamer for label-free detection of Ochratoxin A in wheat
    Zhang, Jing
    Zhang, Xi
    Yang, Guidi
    Chen, Jinghua
    Wang, Shihua
    BIOSENSORS & BIOELECTRONICS, 2013, 41 : 704 - 709
  • [37] A signal-on fluorescent aptasensor based on Tb3+ and structure-switching aptamer for label-free detection of Ochratoxin A in wheat
    Zhang, Jing
    Zhang, Xi
    Yang, Guidi
    Chen, Jinghua
    Wang, Shihua
    Biosensors and Bioelectronics, 2013, 41 (01) : 704 - 709
  • [38] Facile and sensitive detection of mercury ions based on fluorescent structure-switching aptamer probe and exonuclease III-assisted signal amplification
    Wang, Boxu
    Liu, Zheng
    Li, Zhihong
    Xu, Ningyi
    Zhang, Xuejiao
    Su, Ruifang
    Wang, Junyang
    Jin, Rui
    Sun, Chunyan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2023, 303
  • [39] Portable and sensitive detection of non-glucose target by enzyme-encapsulated metal-organic-framework using personal glucose meter
    Cao, Yunzhe
    Mo, Fengye
    Liu, Yahua
    Liu, Yu
    Li, Gaiping
    Yu, Wenqian
    Liu, Xiaoqing
    BIOSENSORS & BIOELECTRONICS, 2022, 198
  • [40] Aptamer-based portable biosensor for platelet-derived growth factor-BB (PDGF-BB) with personal glucose meter readout
    Ma, Xiaoming
    Chen, Zhonghui
    Zhou, Jin
    Weng, Wen
    Zheng, Ou
    Lin, Zhenyu
    Guo, Longhua
    Qiu, Bin
    Chen, Guonan
    BIOSENSORS & BIOELECTRONICS, 2014, 55 : 412 - 416