Portable Detection of Melamine in Milk Using a Personal Glucose Meter Based on an in Vitro Selected Structure-Switching Aptamer

被引:129
|
作者
Gu, Chunmei [1 ,2 ]
Lan, Tian [2 ]
Shi, Hanchang [1 ]
Lu, Yi [2 ,3 ]
机构
[1] Tsinghua Univ, Sch Environm, State Key Joint Lab ESPC, Beijing 100084, Peoples R China
[2] Univ Illinois, Dept Biochem, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
基金
美国国家科学基金会;
关键词
CAPILLARY-ZONE-ELECTROPHORESIS; MASS-SPECTROMETRIC DETECTION; POINT-OF-CARE; EXPONENTIAL ENRICHMENT; QUANTITATIVE DETECTION; SYSTEMATIC EVOLUTION; RAPID DETECTION; INFANT FORMULA; CYANURIC ACID; CELL-SELEX;
D O I
10.1021/acs.analchem.5b01085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Melamine detection in milk and other foods has attracted much attention since the discovery that melamine-adulterated food causes severe kidney damage. Although many methods have been developed to detect melamine, few methods can provide quantitative results using an affordable and portable device that is suitable for home use or field application. To achieve this goal, we herein report the first in vitro selection of a melamine responsive aptamer using a structure-switching method. A personal glucose meter (PGM) based melamine sensor was designed and subsequently tested using the newly isolated aptamer. Conversion of melamine concentration to glucose amount was achieved by including an invertase-conjugated DNA that is complementary to part of the aptamer. Melamine binding triggers the release of the invertase-DNA conjugate, which hydrolyzes sucrose into glucose. The glucose produced is then measured directly using an off-the-shelf PGM. The described sensor shows high selectivity for melamine against several closely related melamine analogues, such as cyanuric acid, ammeline, and ammelide, and has low detection limits of 0.33 mu M (or 41.1 ppb) in buffer and 0.53 mu M (or 67.5 ppb) in 80% whole milk without any pretreatment. The detection limits meet the threshold of 2.5 ppm for non-infant-formula products and 1 ppm for melamine in infant milk products as defined by the U.S. Food and Drug Administration (FDA). In addition to the PGM sensor demonstrated here, the same aptamer can be converted into other types of sensors with different signal outputs, allowing portable detection of melamine under a variety of conditions.
引用
收藏
页码:7676 / 7682
页数:7
相关论文
共 50 条
  • [11] Portable detection of Staphylococcus aureus using personal glucose meter based on hybridization chain reaction strategy
    Yang, Yuemeng
    Wu, Tingting
    Xu, Li-Ping
    Zhang, Xueji
    TALANTA, 2021, 226
  • [12] A Catechol-Meter Based on Conventional Personal Glucose Meter for Portable Detection of Tyrosinase and Sodium Benzoate
    Tian, Tao
    Zhang, Wei-Yi
    Zhou, Hang-Yu
    Peng, Li-Jing
    Zhou, Xi
    Zhang, Hao
    Yang, Feng-Qing
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [13] Sensitive and portable detection of telomerase activity in HeLa cells using the personal glucose meter
    Zhu, Xi
    Xu, Huifeng
    Lin, Ruolan
    Yang, Guidi
    Lin, Zhenyu
    Chen, Guonan
    CHEMICAL COMMUNICATIONS, 2014, 50 (58) : 7897 - 7899
  • [14] Portable and sensitive detection of protein kinase activity by using commercial personal glucose meter
    Yang, Wenxia
    Lu, Xiaohui
    Wang, Yucong
    Sun, Sujuan
    Liu, Chenghui
    Li, Zhengping
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 508 - 512
  • [15] A one-step electrochemical sensor for rapid detection of potassium ion based on structure-switching aptamer
    Chen, Zhengbo
    Guo, Junxia
    Zhang, Suge
    Chen, Liang
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 1155 - 1157
  • [16] Aptamer-based detection of melamine in milk using an evanescent wave fiber sensor
    Qiu, Yong
    Tang, Yunfei
    Li, Bing
    Gu, Chunmei
    He, Miao
    ANALYTICAL METHODS, 2018, 10 (40) : 4871 - 4878
  • [17] Construction of a portable immunosensor for the sensitive detection of carbendazim in agricultural products using a personal glucose meter
    Liu, Haoran
    Xie, Longyingzi
    Wang, Yiwen
    Liu, Yanlin
    Fu, Ruijie
    Cui, Yongliang
    Zhao, Qiyang
    Wang, Chengqiu
    Jiao, Bining
    He, Yue
    FOOD CHEMISTRY, 2023, 407
  • [18] Sensitive, Semiquantitative, and Portable Nucleic Acid Detection of Rabies Virus Using a Personal Glucose Meter
    Lu, Jiaying
    Bai, Yujie
    Wang, Xuejin
    Huang, Pei
    Liu, Meihui
    Wang, Ruijia
    Zhang, Haili
    Wang, Hualei
    Li, Yuanyuan
    ACS OMEGA, 2024, 9 (24): : 26058 - 26065
  • [19] Portable detection of colorectal cancer SW620 cells by using a personal glucose meter
    Zhou, Jun
    Duan, Lunxi
    Huang, Jiangsheng
    Zuo, Zhongkun
    Tang, Tenglong
    Cao, Ding
    Ye, Fei
    Zhou, Shiwei
    Zhou, Yueying
    Zhang, Leiyi
    ANALYTICAL BIOCHEMISTRY, 2019, 577 : 110 - 116
  • [20] A portable and efficient strategy for ofloxacin detection using Ce-based MOF-loaded glucose oxidase and a personal glucose meter
    Wang, Qianqian
    He, Baoshan
    Liu, Yao
    Wu, Ligen
    Zhao, Wenhong
    Xie, Dongdong
    Ren, Wenjie
    Xu, Yiwei
    ANALYTICA CHIMICA ACTA, 2025, 1351