Portable Detection of Melamine in Milk Using a Personal Glucose Meter Based on an in Vitro Selected Structure-Switching Aptamer

被引:129
|
作者
Gu, Chunmei [1 ,2 ]
Lan, Tian [2 ]
Shi, Hanchang [1 ]
Lu, Yi [2 ,3 ]
机构
[1] Tsinghua Univ, Sch Environm, State Key Joint Lab ESPC, Beijing 100084, Peoples R China
[2] Univ Illinois, Dept Biochem, Urbana, IL 61801 USA
[3] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
基金
美国国家科学基金会;
关键词
CAPILLARY-ZONE-ELECTROPHORESIS; MASS-SPECTROMETRIC DETECTION; POINT-OF-CARE; EXPONENTIAL ENRICHMENT; QUANTITATIVE DETECTION; SYSTEMATIC EVOLUTION; RAPID DETECTION; INFANT FORMULA; CYANURIC ACID; CELL-SELEX;
D O I
10.1021/acs.analchem.5b01085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Melamine detection in milk and other foods has attracted much attention since the discovery that melamine-adulterated food causes severe kidney damage. Although many methods have been developed to detect melamine, few methods can provide quantitative results using an affordable and portable device that is suitable for home use or field application. To achieve this goal, we herein report the first in vitro selection of a melamine responsive aptamer using a structure-switching method. A personal glucose meter (PGM) based melamine sensor was designed and subsequently tested using the newly isolated aptamer. Conversion of melamine concentration to glucose amount was achieved by including an invertase-conjugated DNA that is complementary to part of the aptamer. Melamine binding triggers the release of the invertase-DNA conjugate, which hydrolyzes sucrose into glucose. The glucose produced is then measured directly using an off-the-shelf PGM. The described sensor shows high selectivity for melamine against several closely related melamine analogues, such as cyanuric acid, ammeline, and ammelide, and has low detection limits of 0.33 mu M (or 41.1 ppb) in buffer and 0.53 mu M (or 67.5 ppb) in 80% whole milk without any pretreatment. The detection limits meet the threshold of 2.5 ppm for non-infant-formula products and 1 ppm for melamine in infant milk products as defined by the U.S. Food and Drug Administration (FDA). In addition to the PGM sensor demonstrated here, the same aptamer can be converted into other types of sensors with different signal outputs, allowing portable detection of melamine under a variety of conditions.
引用
收藏
页码:7676 / 7682
页数:7
相关论文
共 50 条
  • [21] A disposable paper-based electrochemical biosensor for detection of aflatoxin B1 based on a structure-switching aptamer
    Li, Zhi
    Ren, Pengcheng
    Cao, Junli
    Lu, Xiaoqin
    Qi, Yanli
    Li, Jindong
    Qin, Shu
    LWT-FOOD SCIENCE AND TECHNOLOGY, 2024, 211
  • [22] Portable aptamer biosensor of platelet-derived growth factor-BB using a personal glucose meter with triply amplified
    Hong, Lu
    Zhou, Fu
    Shi, Dongmin
    Zhang, Xiaojun
    Wang, Guangfeng
    BIOSENSORS & BIOELECTRONICS, 2017, 95 : 152 - 159
  • [23] Fluorescence anisotropy-based structure-switching aptamer assay using a peptide nucleic acid (PNA) probe
    Goux, Emma
    Lespinasse, Quentin
    Guieu, Valerie
    Perrier, Sandrine
    Ravelet, Corinne
    Fiore, Emmanuelle
    Peyrin, Eric
    METHODS, 2016, 97 : 69 - 74
  • [24] Cortisol Detection in Undiluted Human Serum Using a Sensitive Electrochemical Structure-Switching Aptamer over an Antifouling Nanocomposite Layer
    Singh, Naveen K.
    Chung, Saeromi
    Sveiven, Michael
    Hall, Drew A.
    ACS OMEGA, 2021, 6 (42): : 27888 - 27897
  • [25] Electrochemical Biosensor for Detection of Adenosine Based on Structure-Switching Aptamer and Amplification with Reporter Probe DNA Modified Au Nanoparticles
    Zhang, Shusheng
    Xia, Jianping
    Li, Xuemei
    ANALYTICAL CHEMISTRY, 2008, 80 (22) : 8382 - 8388
  • [26] Immunoglobulin E Detection Method Based on Cascade Enzymatic Reaction Utilizing Portable Personal Glucose Meter
    Han, Hyogu
    Park, Junhyun
    Ahn, Jun Ki
    SENSORS, 2021, 21 (19)
  • [27] Structure-switching aptamer triggering signal amplification strategy for tobramycin detection based on hybridization chain reaction and fluorescence synergism
    Wang, Junyang
    Li, Hongxia
    Du, Caiyi
    Li, Ying
    Ma, Xinyue
    Yang, Chuanyu
    Xu, Wentao
    Sun, Chunyan
    Talanta, 2022, 243
  • [28] Novel fluorescence strategy based on G-quadruplex structure-switching aptamer for enrofloxacin detection in food and environmental samples
    Shen, Gang
    Ma, Yingnan
    Zhang, Hong
    Wang, Fangfang
    Yang, Fengmin
    Ye, Huanfeng
    Li, Runzhi
    Wang, Changzheng
    Tang, Yalin
    FOOD CHEMISTRY, 2024, 441
  • [29] No Structure-Switching Required: A Generalizable Exonuclease-Mediated Aptamer-Based Assay for Small-Molecule Detection
    Canoura, Juan
    Wang, Zongwen
    Yu, Haixiang
    Alkhamis, Obtin
    Fu, Fengfu
    Xiao, Yi
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2018, 140 (31) : 9961 - 9971
  • [30] Quantitative and selective DNA detection with portable personal glucose meter using loop-based DNA competitive hybridization strategy
    Shan, Yanke
    Zhang, Yan
    Kang, Wenjie
    Wang, Bin
    Li, Jiahao
    Wu, Xuping
    Wang, Shouyu
    Liu, Fei
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 282 : 197 - 203