Highly sensitive detection of M.SssI DNA methyltransferase activity using a personal glucose meter

被引:16
|
作者
Deng, Huimin [1 ,2 ]
Peng, Si Ying [1 ]
Gao, Zhiqiang [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Sci Dr 3, Singapore 117543, Singapore
[2] China Natl Tobacco Qual Supervis & Test Ctr, Zhengzhou 450001, Henan, Peoples R China
关键词
DNA Methyltransferase; Invertase; Electrochemical biosensor; M.SssIMTase; QUANTITATIVE DETECTION; METHYLATION; CANCER; TARGET; QUANTIFICATION; 5-AZACYTIDINE; GLUCOMETER; INHIBITORS; READOUT; GENE;
D O I
10.1007/s00216-016-9701-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple method for highly sensitive and selective detection of M.SssI CpG methyltransferase (M.SssI MTase) activity is developed, leveraging on the portability and ease of use of a personal glucose meter (PGM). Briefly, DNA-invertase conjugates are hybridized with their complementary DNA strands pre-immobilized on magnetic beads. The 5'-CCGG-3' sequence present in the DNA duplexes serves as the recognition site for both Hpa II restriction enzyme and M.SssI MTase (5'-CG-3'). Hpa II restriction enzyme specifically cleaves at unmethylated 5'-CCGG-3' sequence, and the invertase that remains on the methylated DNA catalyzes the hydrolysis of sucrose to glucose and fructose. It is found that the amount of glucose is proportional to the M.SssI MTase methylation activity in the range of 0.5 to 80 U/mL with a detection limit of 0.37 U/mL. Due to the specific recognition sequence present in the DNA strands, this method also shows high selectivity for M.SssI MTase. In addition, inhibition studies with 5'-azacytidine demonstrate the capability of inhibition screening using this method.
引用
收藏
页码:5867 / 5872
页数:6
相关论文
共 50 条
  • [1] Highly sensitive detection of M.SssI DNA methyltransferase activity using a personal glucose meter
    Huimin Deng
    Si Ying Peng
    Zhiqiang Gao
    Analytical and Bioanalytical Chemistry, 2016, 408 : 5867 - 5872
  • [2] Correction to: Highly sensitive detection of M.SssI DNA methyltransferase activity using a personal glucose meter
    Huimin Deng
    Si Ying Png
    Zhiqiang Gao
    Analytical and Bioanalytical Chemistry, 2018, 410 : 6033 - 6033
  • [3] Highly sensitive detection of M.SssI DNA methyltransferase activity using a personal glucose meter (vol 408, pg 5867, 2016)
    Deng, Huimin
    Png, Si Ying
    Gao, Zhiqiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (23) : 6033 - 6033
  • [4] DNA Methyltransferase activity detection using the personal glucose meter
    Deng, Huimin
    Png, Si Ying
    Gao, Zhiqiang
    2015 9TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2015, : 28 - 33
  • [5] Identification of Novel Bacterial M.SssI DNA Methyltransferase Inhibitors
    Hupkes, Marlinda
    Azevedo, Rita
    Jansen, Hans
    van Zoelen, Everardus J.
    Dechering, Koen J.
    JOURNAL OF BIOMOLECULAR SCREENING, 2013, 18 (03) : 348 - 355
  • [6] Photoelectrochemical determination of the activity of M.SssI methyltransferase, and a method for inhibitor screening
    Liu, Xiao
    Wei, Chenghua
    Luo, Jing
    Wu, Yiping
    Guo, Xiaoyu
    Ying, Ye
    Wen, Ying
    Yang, Haifeng
    MICROCHIMICA ACTA, 2018, 185 (11)
  • [7] Photoelectrochemical determination of the activity of M.SssI methyltransferase, and a method for inhibitor screening
    Xiao Liu
    Chenghua Wei
    Jing Luo
    Yiping Wu
    Xiaoyu Guo
    Ye Ying
    Ying Wen
    Haifeng Yang
    Microchimica Acta, 2018, 185
  • [8] Magnetic bead-liposome hybrids enable sensitive and portable detection of DNA methyltransferase activity using personal glucose meter
    Zhang, Youna
    Xue, Qingwang
    Liu, Jifeng
    Wang, Huaisheng
    BIOSENSORS & BIOELECTRONICS, 2017, 87 : 537 - 544
  • [9] Portable and sensitive detection of protein kinase activity by using commercial personal glucose meter
    Yang, Wenxia
    Lu, Xiaohui
    Wang, Yucong
    Sun, Sujuan
    Liu, Chenghui
    Li, Zhengping
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 : 508 - 512
  • [10] Sensitive and portable detection of telomerase activity in HeLa cells using the personal glucose meter
    Zhu, Xi
    Xu, Huifeng
    Lin, Ruolan
    Yang, Guidi
    Lin, Zhenyu
    Chen, Guonan
    CHEMICAL COMMUNICATIONS, 2014, 50 (58) : 7897 - 7899