Efficacy of MAVIG X-Ray Protective Drapes in Reducing Operator Radiation Dose in the Cardiac Catheterization Laboratory A Randomized Controlled Trial

被引:10
|
作者
McCutcheon, Keir [1 ,3 ]
Vanhaverbeke, Maarten [1 ]
Pauwels, Ruben [1 ]
Dabin, Jeremie [2 ]
Schoonjans, Werner [2 ]
Bennett, Johan [1 ,3 ]
Adriaenssens, Tom [1 ,3 ]
Dubois, Christophe [1 ,3 ]
Sinnaeve, Peter [1 ,3 ]
Desmet, Walter [1 ,3 ]
机构
[1] Univ Hosp Leuven, Dept Cardiovasc Dis, Herestr 49, B-3000 Leuven, Belgium
[2] Belgian Nucl Res Ctr, Res Dosimetr Applicat, Mol, Belgium
[3] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
关键词
cardiac catheterization; cardiologists; percutaneous coronary intervention; radiation; risk; PELVIC LEAD SHIELD; PERCUTANEOUS CORONARY INTERVENTION; IONIZING-RADIATION; THREEFOLD DECREASE; DOUBLE-EXPOSURE; REDUCTION; ACCESS; DETERMINANTS; INSIGHTS; PATIENT;
D O I
10.1161/CIRCINTERVENTIONS.120.009627
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Interventional cardiologists are occupationally exposed to high doses of ionizing radiation. The MAVIG X-ray protective drape (MXPD) is a commercially available light weight, lead-free shield placed over the pelvic area of patients to minimize operator radiation dose. The aim of this study was to examine the efficacy of the MXPD during routine cardiac catheterization, including percutaneous coronary interventions. Methods: We performed a prospective, randomized controlled study comparing operator radiation dose during cardiac catheterization and percutaneous coronary intervention (n=632) with or without pelvic MXPD. We measured operator radiation dose at 4 sites: left eye, chest, left ring finger, and right ring finger. The primary outcomes were the difference in first operator radiation dose (mu Sv) and relative dose of the first operator (radiation dose normalized for dose area product) at the level of the chest in the 2 groups. Results: The use of the MXPD was associated with a 50% reduction in operator radiation dose (median dose 30.5 [interquartile range, 23.0-39.7] mu Sv in no drape group versus 15.3 [interquartile range, 11.1-20.0] mu Sv in the drape group; P<0.001) and a 57% reduction in relative operator dose (P<0.001). The largest absolute reduction in dose was observed at the left finger (median left finger dose for the no drape group was 104.9 [75.7-137.4] mu Sv versus 41.9 [32.6-70.6] mu Sv in the drape group; P<0.001). Conclusions: The pelvic MXPD significantly reduces first operator radiation dose during routine cardiac catheterization and percutaneous coronary intervention. REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT04285944.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Diagnostic Imaging of Spinal Deformities Reducing Patients Radiation Dose With a New Slot-Scanning X-ray Imager
    Deschenes, Sylvain
    Charron, Guy
    Beaudoin, Gilles
    Labelle, Hubert
    Dubois, Josee
    Miron, Marie-Claude
    Parent, Stefan
    SPINE, 2010, 35 (09) : 989 - 994
  • [42] Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention
    Nakamura, Shigeru
    Kobayashi, Tomoko
    Funatsu, Atsushi
    Okada, Tadahisa
    Mauti, Maria
    Waizumi, Yuki
    Yamada, Shinichi
    HEART AND VESSELS, 2016, 31 (05) : 655 - 663
  • [43] Patient radiation dose reduction using an X-ray imaging noise reduction technology for cardiac angiography and intervention
    Shigeru Nakamura
    Tomoko Kobayashi
    Atsushi Funatsu
    Tadahisa Okada
    Maria Mauti
    Yuki Waizumi
    Shinichi Yamada
    Heart and Vessels, 2016, 31 : 655 - 663
  • [44] Efficacy of a single dose intravenous heparin in reducing sheath-thrombus formation during diagnostic angiography: A randomized controlled trial
    Alamri, Hussein S.
    Almoghairi, Abdulrahman M.
    Alghamdi, Abdullah A.
    Almasood, Ali S.
    Alotaiby, Mohamed A.
    Kazim, Hameedullah M.
    Almutairi, Meshal
    Alanazi, Aziz
    JOURNAL OF THE SAUDI HEART ASSOCIATION, 2012, 24 (01) : 3 - 7
  • [45] Thermal and Mechanical Properties of Protective Clothing Material Developed against Medical X-ray radiation for Reducing Physical Load on the Wearer
    Kumada A.
    Kawahara N.
    Sakashita R.
    Kobayashi S.
    Morooka H.
    Journal of the Japan Research Association for Textile End-Uses, 2022, 63 (05): : 323 - 330
  • [46] Effectiveness of additional X-ray protection devices in reducing Scattered radiation in radial interventions: protocol of the ESPRESSO randomised trial
    Anadol, Remzi
    Brandt, Moritz
    Merz, Nico
    Knorr, Maike
    Ahoopai, Majid
    Geyer, Martin
    Krompiec, Damian
    Wenzel, Phillip
    Muenzel, Thomas
    Gori, Tommaso
    BMJ OPEN, 2019, 9 (07):
  • [47] γ-H2AX Foci as a Biomarker for Patient X-Ray Exposure in Pediatric Cardiac Catheterization Are We Underestimating Radiation Risks?
    Beels, Laurence
    Bacher, Klaus
    De Wolf, Daniel
    Werbrouck, Joke
    Thierens, Hubert
    CIRCULATION, 2009, 120 (19) : 1903 - 1909
  • [48] Efficacy of high dose Allopurinol in reducing left ventricular mass in patients with left ventricular hypertrophy by comparing its efficacy with Febuxostat - a randomized controlled trial
    Lal, Balwant
    Iqbal, Adil
    Butt, Nasir Farooq
    Randhawa, Fawad Ahmad
    Rathore, Rabia
    Waseem, Tariq
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2018, 68 (10) : 1446 - 1450
  • [49] Reducing the radiation dose during excretory urography:: Flat-panel silicon X-ray detector versus computed radiography
    Zähringer, M
    Hesselmann, V
    Schulte, O
    Kamm, KF
    Braun, W
    Haupt, G
    Krug, B
    Lackner, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (04) : 931 - 937
  • [50] Assessment of Radiation Dose and Shielding Efficacy in DDR Versus Mobile C-Arm and Portable X-Ray Systems
    Siddique, A.
    Ge, G. Y.
    Lemieux, B.
    Zhang, J.
    MEDICAL PHYSICS, 2024, 51 (10) : 7775 - 7775