Strain Measurements With Langasite SAW Resonators at High Temperature

被引:23
|
作者
Li, Ling [1 ]
Peng, Bin [1 ]
Zhu, Jialiang [2 ]
He, Zhengxi [2 ]
Yang, Yuntao [1 ]
Zhang, Wanli [1 ]
机构
[1] Univ Elect Sci & Technol China, State Key Lab Elect Thin Films & Integrated Devic, Chengdu 611731, Peoples R China
[2] Nucl Power Inst China, Sci & Technol Reactor Syst Design Technol Lab, Chengdu 610213, Peoples R China
关键词
LGS; high temperature; surface acoustic wave; strain sensor;
D O I
10.1109/JSEN.2020.3032477
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The strain sensitivities of the langasite surface acoustic wave resonators are strongly dependent on the temperature, which causes measurement strain to shift greatly at high temperature. To cancel the effect of temperature, a surface acoustic wave strain sensor which consisted of three langasite surface acoustic wave resonators was presented in this work. The surface acoustic wave resonators are configured to ensure that the propagation directions of the surface acoustic wave in the three surface acoustic wave resonators are parallel, perpendicular and at an orientation of 30 degrees to the applied strain. The strain sensitivities of the three surface acoustic wave resonators from room temperature to 250 degrees C were investigated. Functional relationships of the resonance frequency shifts of the three surface acoustic wave resonators due to both the temperature and applied strain were established. It was deduced that the strain was linearly represented by the resonance frequency shifts of the three surface acoustic wave resonators. Experimental results demonstrated that the langasite surface acoustic wave strain sensor was well worked within the temperature range from room temperature to 250 degrees C. The average values of the calculated strains were in agreement with the practical applied strains. There was a little fluctuation between the calculated and preset strains. The measurement error was about 1%. The maximal standard deviation was about 18.5 mu epsilon.
引用
收藏
页码:4688 / 4695
页数:8
相关论文
共 50 条
  • [1] High-Temperature SAW Wireless Strain Sensor with Langasite
    Shu, Lin
    Peng, Bin
    Yang, Zhengbing
    Wang, Rui
    Deng, Senyang
    Liu, Xingzhao
    [J]. SENSORS, 2015, 15 (11) : 28531 - 28542
  • [2] Test and Analysis of SAW High Temperature Strain Sensor Based on Langasite
    Yan, Xiawen
    Tan, Qiulin
    Li, Xiangrong
    Xue, Tao
    Li, Meipu
    [J]. IEEE SENSORS JOURNAL, 2022, 22 (13) : 12622 - 12628
  • [3] High temperature SAW gas sensor on langasite
    Thiele, JA
    da Cunha, MP
    [J]. PROCEEDINGS OF THE IEEE SENSORS 2003, VOLS 1 AND 2, 2003, : 769 - 772
  • [4] Langasite: High Temperature Properties and SAW Simulations
    Weihnacht, M.
    Sotnikov, A.
    Schmidt, H.
    Wall, B.
    Gruenwald, R.
    [J]. 2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1549 - 1552
  • [5] High temperature operation and stability of langasite resonators
    Fritze, H
    Schulz, M
    Seh, H
    Tuller, HL
    [J]. SEMICONDUCTOR MATERIALS FOR SENSING, 2005, 828 : 145 - 150
  • [6] High temperature operation and stability of langasite resonators
    Fritze, H
    Schulz, M
    Seh, H
    Tuller, HL
    [J]. SOLID STATE IONICS-2004, 2005, 835 : 157 - 162
  • [7] Optimization of Aperture in SAW and STW Resonators on Langasite
    Naumenko, Natalya F.
    [J]. 2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, : 2059 - 2062
  • [8] High-Temperature Langasite SAW Oxygen Sensor
    Zheng, Peng
    Chin, Tao-Lun
    Greve, David
    Oppenheim, Irving
    Malone, Vanessa
    Cao, Limin
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (08) : 1538 - 1540
  • [9] Characterization of Langasite for Application in High Temperature SAW Sensors
    Sakharov, S.
    Naumenko, N.
    Zabelin, A.
    Zhgoon, S.
    [J]. 2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 2289 - 2292