Glucose concentration monitoring using a small Fabry-Perot etalon

被引:2
|
作者
Martini, Joerg [1 ]
Kiesel, Peter [1 ]
Roe, Jeffrey [1 ]
Bruce, Richard H. [1 ]
机构
[1] Palo Alto Res Ctr, Hardware Syst Lab, Palo Alto, CA 94304 USA
关键词
refractive index; etalon; glucose detection; diabetes; continuous glucose monitoring (CGM); analyte assay; medical implant; vertical-cavity surface-emitting laser (VCSEL); CONCANAVALIN-A; REFRACTOMETRY; HYPOGLYCEMIA; BINDING; INSULIN; SENSOR;
D O I
10.1117/1.3153848
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate measurements of aqueous glucose concentrations have been made in a double-chamber Fabry-Perot etalon that can be miniaturized for subcutaneous implantation to determine the concentration of glucose in interstitial fluid. In general, optical approaches to glucose detection measure light intensity, which in tissue varies due to inherent scattering and absorption. In our measurements, we compare the spectral positions of transmission maximums in two adjunct sections of an etalon in order to determine the refractive index difference between these sections and therefore we can tolerate large changes in intensity. With this approach, we were able to determine aqueous glucose concentrations between 0 mg/dl and 700 mg/dl within the precision of our reference measurement (+/- 2.5 mg/dl or 2% of the measurement value). The use of reference cavities eliminates interference due to temperature variations, and we show the temperature independence over a temperature range of 32 degrees C to 42 degrees C. Furthermore, external filters eliminate interference from large molecule contaminants. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3153848]
引用
收藏
页数:8
相关论文
共 50 条
  • [31] LOW-COST FABRY-PEROT ETALON
    HILTON, JW
    AMERICAN JOURNAL OF PHYSICS, 1968, 36 (01) : R9 - &
  • [32] INTENSITY TRANSMITTED BY A FABRY-PEROT ETALON WITH ANOTHER INTERNAL FABRY-PEROT-INTERFEROMETER
    BERNABEU, E
    AMARE, JC
    ALVAREZ, JM
    MORENO, F
    APPLIED OPTICS, 1981, 20 (12): : 2117 - 2120
  • [33] High frequency ultrasound imaging using Fabry-Perot optical etalon
    Ashkenazi, S
    Witte, R
    O'Donnell, M
    Medical Imaging 2005: Ultrasonic Imaging and Signal Processing, 2005, 5750 : 289 - 297
  • [34] High frequency ultrasound imaging using Fabry-Perot optical etalon
    Ashkenazi, S
    Witte, R
    O'Donnell, M
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2005, 2005, 5697 : 243 - 250
  • [35] Angular probe based on using Fabry-Perot etalon and scanning technique
    Lin, Shyh-Tsong
    Yeh, Sheng-Lih
    Lin, Zhi-Feng
    OPTICS EXPRESS, 2010, 18 (03): : 1794 - 1800
  • [36] High Frequency ultrasound detection using Fabry-Perot optical etalon
    Ashkenazi, S
    Buma, T
    O'Donnell, M
    2004 IEEE Ultrasonics Symposium, Vols 1-3, 2004, : 68 - 71
  • [37] FULL-FIELD VIBROMETRY USING A FABRY-PEROT ETALON INTERFEROMETER
    OURSLER, DA
    WAGNER, JW
    APPLIED OPTICS, 1992, 31 (34): : 7301 - 7308
  • [38] Loss measurements for an optical cavity with a Fabry-Perot etalon
    Pinayev, I.V.
    Popik, V.M.
    Shaftan, T.V.
    Sokolov, A.S.
    Vinokurov, N.A.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A341 (1-3)
  • [39] MEASURING THE SURFACE-DEFECTS OF A FABRY-PEROT ETALON
    ANDERSON, DJ
    APPLIED OPTICS, 1995, 34 (34): : 8062 - 8063
  • [40] CRYOGENIC FAR-INFRARED FABRY-PEROT ETALON
    PETERSON, DB
    PICKETT, HM
    APPLIED OPTICS, 1991, 30 (31): : 4493 - 4495