摘要
Accurate measurements of aqueous glucose concentrations have been made in a double-chamber Fabry-Perot etalon that can be miniaturized for subcutaneous implantation to determine the concentration of glucose in interstitial fluid. In general, optical approaches to glucose detection measure light intensity, which in tissue varies due to inherent scattering and absorption. In our measurements, we compare the spectral positions of transmission maximums in two adjunct sections of an etalon in order to determine the refractive index difference between these sections and therefore we can tolerate large changes in intensity. With this approach, we were able to determine aqueous glucose concentrations between 0 mg/dl and 700 mg/dl within the precision of our reference measurement (+/- 2.5 mg/dl or 2% of the measurement value). The use of reference cavities eliminates interference due to temperature variations, and we show the temperature independence over a temperature range of 32 degrees C to 42 degrees C. Furthermore, external filters eliminate interference from large molecule contaminants. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3153848]
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Nonreciprocal photorefractive Fabry-Perot etalon
    Mak, W.K.
    Lee, W.K.
    Proceedings of SPIE - The International Society for Optical Engineering, 1994, 2321 : 162 - 164
  • [12] RECORDING SPECTROPHOTOMETER WITH FABRY-PEROT ETALON
    DRAGANESCU, V
    AGAFITEI, A
    COMANICIU, N
    NITOIU, A
    REVUE ROUMAINE DE PHYSIQUE, 1964, 9 (08): : 733 - +
  • [13] A Fabry-Perot etalon as Fourier tachometer
    Kozhevatov, IE
    Kulikova, EH
    Cheragin, NP
    SOLAR PHYSICS, 1996, 168 (02) : 251 - 258
  • [14] A SIMPLE STABLE FABRY-PEROT ETALON
    HINDLE, PH
    REAY, NK
    RING, J
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1967, 44 (08): : 464 - &
  • [15] Design of a liquid crystal Fabry-Perot etalon and analysis of resonant mode splitting of a birefringent Fabry-Perot etalon
    Jiao, MX
    Qi, RL
    Liu, ZZ
    Xing, JH
    HIGH-POWER LASERS AND APPLICATIONS III, 2004, 5627 : 473 - 480
  • [16] Liquid Crystal Phase Transitions Using Fabry-Perot Etalon
    Gupta, Suresh Chandra J.
    Journal of Optics (India), 2000, 29 (02): : 53 - 62
  • [17] Phase transition temperatures of LCs using Fabry-Perot etalon
    Gupta, SJ
    Gharde, RA
    Tripathi, AR
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2001, 364 : 461 - 468
  • [18] FURTHER DEVELOPMENT OF REABSORPTION METHOD USING A FABRY-PEROT ETALON
    LUIZOVA, LA
    OPTICS AND SPECTROSCOPY-USSR, 1967, 23 (05): : 455 - &
  • [19] TUNING PROPERTIES OF A BIREFRINGENT FABRY-PEROT ETALON
    FROLICH, D
    WELLING, H
    APPLIED PHYSICS, 1976, 9 (03): : 205 - 207
  • [20] THE FABRY-PEROT ETALON WITH A SMALL TRANSPARENT APERTURE AND SOME OF ITS CHARACTERISTICS
    NAGIBINA, IM
    KOROLEV, AN
    OPTIKA I SPEKTROSKOPIYA, 1963, 15 (03): : 421 - 423