Glucose concentration monitoring using a small Fabry-Perot etalon

被引:2
|
作者
Martini, Joerg [1 ]
Kiesel, Peter [1 ]
Roe, Jeffrey [1 ]
Bruce, Richard H. [1 ]
机构
[1] Palo Alto Res Ctr, Hardware Syst Lab, Palo Alto, CA 94304 USA
关键词
refractive index; etalon; glucose detection; diabetes; continuous glucose monitoring (CGM); analyte assay; medical implant; vertical-cavity surface-emitting laser (VCSEL); CONCANAVALIN-A; REFRACTOMETRY; HYPOGLYCEMIA; BINDING; INSULIN; SENSOR;
D O I
10.1117/1.3153848
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate measurements of aqueous glucose concentrations have been made in a double-chamber Fabry-Perot etalon that can be miniaturized for subcutaneous implantation to determine the concentration of glucose in interstitial fluid. In general, optical approaches to glucose detection measure light intensity, which in tissue varies due to inherent scattering and absorption. In our measurements, we compare the spectral positions of transmission maximums in two adjunct sections of an etalon in order to determine the refractive index difference between these sections and therefore we can tolerate large changes in intensity. With this approach, we were able to determine aqueous glucose concentrations between 0 mg/dl and 700 mg/dl within the precision of our reference measurement (+/- 2.5 mg/dl or 2% of the measurement value). The use of reference cavities eliminates interference due to temperature variations, and we show the temperature independence over a temperature range of 32 degrees C to 42 degrees C. Furthermore, external filters eliminate interference from large molecule contaminants. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3153848]
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Tuneable Fabry-Perot etalon for terahertz radiation
    Jewell, S. A.
    Hendry, E.
    Isaac, T. H.
    Sambles, J. R.
    NEW JOURNAL OF PHYSICS, 2008, 10
  • [22] Thermal model of a switching Fabry-Perot etalon
    Bovard, Bertrand
    Macleod, H.Angus
    Proceedings of SPIE - The International Society for Optical Engineering, 1988, 821 : 187 - 197
  • [23] THE FABRY-PEROT ETALON AS AN RF FREQUENCY CHANNELIZER
    ALEXANDER, EM
    GAMMON, RW
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 464 : 45 - 52
  • [24] A DEVICE FOR ALIGNING A LARGE FABRY-PEROT ETALON
    ROGERS, GL
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (11): : 1006 - &
  • [25] Chromatic drift of the Espresso Fabry-Perot etalon
    Schmidt, Tobias M.
    Chazelas, Bruno
    Lovis, Christophe
    Dumusque, Xavier
    Bouchy, Francois
    Pepe, Francesco
    Figueira, Pedro
    Sosnowska, Danuta
    ASTRONOMY & ASTROPHYSICS, 2022, 664
  • [26] GRAVITY-ADJUSTED FABRY-PEROT ETALON
    BURNETT, CR
    LAMMER, WE
    APPLIED OPTICS, 1969, 8 (11): : 2345 - &
  • [27] OPTICALLY-ACTIVE FABRY-PEROT ETALON
    LALOV, IJ
    MITEVA, AI
    JOURNAL OF MODERN OPTICS, 1991, 38 (02) : 395 - 411
  • [28] Volume hologram - Coupled Fabry-Perot etalon
    He, XD
    Liu, DH
    Zhou, J
    OPTIK, 2003, 114 (08): : 379 - 383
  • [29] Temperature insensitive design of Fabry-Perot etalon
    Shirasaki, M
    IEEE PHOTONICS TECHNOLOGY LETTERS, 1999, 11 (11) : 1431 - 1433
  • [30] ANALYTICAL DESCRIPTION OF AN IMPERFECT FABRY-PEROT ETALON
    PRIKRYL, I
    APPLIED OPTICS, 1984, 23 (04): : 621 - 627