New d-dimer threshold for Japanese patients with suspected pulmonary embolism: a retrospective cohort study

被引:1
|
作者
Takahashi, Jin [1 ]
Shiga, Takashi [1 ,2 ]
Fukuyama, Yuita [1 ]
Hoshina, Yuiko [3 ]
Homma, Yosuke [1 ]
Mizobe, Michiko [1 ]
Numata, Kenji [1 ]
Inoue, Tetsuya [1 ]
Funakoshi, Hiraku [1 ]
机构
[1] Tokyo Bay Urayasu Ichikawa Med Ctr, Dept Emergency & Crit Care Med, 3-4-32 Todaijima, Chiba 2790001, Japan
[2] Int Univ Hlth & Welf, Dept Emergency Med, Minato Ku, 1-4-3 Mita, Tokyo 1088329, Japan
[3] Tokyo Bay Urayasu Ichikawa Med Ctr, Div Strateg Planning & Anal, 3-4-32 Todaijima, Chiba 2790001, Japan
关键词
Pulmonary embolism; New d-dimer threshold; Emergency department; Japan; Factor V Leiden; Prothrombin gene G20210A mutations; FACTOR-V-LEIDEN; EMERGENCY-DEPARTMENT PATIENTS; RULE-OUT CRITERIA; VENOUS THROMBOEMBOLISM; COMPUTED-TOMOGRAPHY; MANAGEMENT; EPIDEMIOLOGY; MUTATION;
D O I
10.1186/s12245-019-0242-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BackgroundIn the diagnosis of pulmonary embolism (PE), the d-dimer threshold is based on studies conducted in Western countries, where the incidence rate is 5 times higher than that in Asian countries, including Japan. If we could elevate the d-dimer threshold based on the low pre-test probability in the Japanese population, we could omit the computed tomography pulmonary angiography (CTPA) which might lead to radiation exposure and contrast-induced nephropathy. Therefore, we aimed to determine a new d-dimer threshold specific to Japanese individuals.MethodsWe conducted a retrospective cohort study at an emergency department in Japan, using medical charts collected from January 2013 to July 2017. We included patients whose d-dimer were measured for suspicion of PE with low or intermediate probability of PE and CTPA were performed. The primary outcome was failure rate of the new d-dimer threshold, defined as the rate of PE detected by CTPA among patients with d-dimer under the new threshold ranging from 1000 to 1500 mu g/L by 100. The new d-dimer threshold was appropriate if the upper limit of 95% confidence interval of the failure rate of PE was approximately 3%.ResultsIn 395 patients included, the number of patients with PE was 24 (the prevalence was 6.1%). If the d-dimer threshold was 1100 mu g/L, the failure rate was 0% (0/119), the upper limit of the 95% confidence interval of the failure rate was 3.1%, and 30% (119/395) of the CTPA might be omitted.ConclusionThe new d-dimer threshold could safely exclude PE. This result can be generalized to other Asian populations with a lower incidence of PE. Further prospective studies will be needed.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Capnometry in suspected pulmonary embolism with positive D-dimer in the field
    Rumpf, Tadeja Hernja
    Krizmaric, Miljenko
    Grmec, Stefek
    CRITICAL CARE, 2009, 13 (06): : R196
  • [32] Capnometry in suspected pulmonary embolism with positive D-dimer in the field
    Tadeja Hernja Rumpf
    Miljenko Križmarić
    Štefek Grmec
    Critical Care, 13
  • [33] The Increasing Use of D-Dimer Testing in Suspected Pulmonary Embolism
    Hoo, Guy Soo
    Barack, Bruce
    Vazirani, Sondra
    Li, Zhaoping
    Wu, Carol
    CHEST, 2015, 148 (04)
  • [34] Concentration of D-DIMER in patients with pulmonary embolism
    Golubovic, M
    MajkicSingh, N
    Vukosavljevic, D
    Maksic, N
    Durdevic, V
    JUGOSLOVENSKA MEDICINSKA BIOHEMIJA-YUGOSLAV MEDICAL BIOCHEMISTRY, 1996, 15 (04): : 302 - 302
  • [35] Evaluation of three new automated D-Dimer tests in patients clinically suspected of pulmonary embolism.
    Hennaux, V
    Para, P
    Chatelain, C
    Delaunois, L
    Chatelain, B
    BLOOD, 1997, 90 (10) : 3227 - 3227
  • [36] D-Dimer for Pulmonary Embolism
    Le Gal, Gregoire
    Righini, Marc
    Wells, Philip S.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2015, 313 (16): : 1668 - 1669
  • [37] Exclusion of the diagnosis of pulmonary embolism in elderly patients by adjustment of the D-dimer threshold: retrospective analysis of three cohorts
    Miroux, P.
    ANNALES FRANCAISES DE MEDECINE D URGENCE, 2011, 1 (03): : 224 - 224
  • [38] The Age Adjusted D-Dimer: A Real World Experience In Patients With Suspected Pulmonary Embolism
    Ramesh, N.
    Lau, M.
    Filopei, J.
    Islam, M.
    Lou, B.
    Bondarsky, E. E.
    Bajpayee, G.
    Duanmu, Y.
    Steiger, D.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [39] Diagnostic value of D-dimer in patients with suspected pulmonary embolism:: Results from a multicentre outcome study
    Parent, Florence
    Maitre, Sophie
    Meyer, Guy
    Raherison, Chantal
    Mal, Herve
    Lancar, Remi
    Couturaud, Francis
    Mottier, Dominique
    Girard, Philippe
    Simonneau, Gerald
    Leroyer, Christophe
    THROMBOSIS RESEARCH, 2007, 120 (02) : 195 - 200
  • [40] Pulmonary embolism in patients with COVID-19 and D-dimer diagnostic value: A retrospective study
    Vivan, Manoela Astolfi
    Rigatti, Brenda
    da Cunha, Sainan Voss
    Frison, Guilherme Cristianetti
    Antoniazzi, Lucas Quadros
    de Oliveira, Paulo Henrique Kranz
    Oliveira, Joao Pedro Souza
    Fontanari, Clara
    Seligman, Beatriz Graeff Santos
    Seligman, Renato
    BRAZILIAN JOURNAL OF INFECTIOUS DISEASES, 2022, 26 (06):