New d-dimer threshold for Japanese patients with suspected pulmonary embolism: a retrospective cohort study

被引:1
|
作者
Takahashi, Jin [1 ]
Shiga, Takashi [1 ,2 ]
Fukuyama, Yuita [1 ]
Hoshina, Yuiko [3 ]
Homma, Yosuke [1 ]
Mizobe, Michiko [1 ]
Numata, Kenji [1 ]
Inoue, Tetsuya [1 ]
Funakoshi, Hiraku [1 ]
机构
[1] Tokyo Bay Urayasu Ichikawa Med Ctr, Dept Emergency & Crit Care Med, 3-4-32 Todaijima, Chiba 2790001, Japan
[2] Int Univ Hlth & Welf, Dept Emergency Med, Minato Ku, 1-4-3 Mita, Tokyo 1088329, Japan
[3] Tokyo Bay Urayasu Ichikawa Med Ctr, Div Strateg Planning & Anal, 3-4-32 Todaijima, Chiba 2790001, Japan
关键词
Pulmonary embolism; New d-dimer threshold; Emergency department; Japan; Factor V Leiden; Prothrombin gene G20210A mutations; FACTOR-V-LEIDEN; EMERGENCY-DEPARTMENT PATIENTS; RULE-OUT CRITERIA; VENOUS THROMBOEMBOLISM; COMPUTED-TOMOGRAPHY; MANAGEMENT; EPIDEMIOLOGY; MUTATION;
D O I
10.1186/s12245-019-0242-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BackgroundIn the diagnosis of pulmonary embolism (PE), the d-dimer threshold is based on studies conducted in Western countries, where the incidence rate is 5 times higher than that in Asian countries, including Japan. If we could elevate the d-dimer threshold based on the low pre-test probability in the Japanese population, we could omit the computed tomography pulmonary angiography (CTPA) which might lead to radiation exposure and contrast-induced nephropathy. Therefore, we aimed to determine a new d-dimer threshold specific to Japanese individuals.MethodsWe conducted a retrospective cohort study at an emergency department in Japan, using medical charts collected from January 2013 to July 2017. We included patients whose d-dimer were measured for suspicion of PE with low or intermediate probability of PE and CTPA were performed. The primary outcome was failure rate of the new d-dimer threshold, defined as the rate of PE detected by CTPA among patients with d-dimer under the new threshold ranging from 1000 to 1500 mu g/L by 100. The new d-dimer threshold was appropriate if the upper limit of 95% confidence interval of the failure rate of PE was approximately 3%.ResultsIn 395 patients included, the number of patients with PE was 24 (the prevalence was 6.1%). If the d-dimer threshold was 1100 mu g/L, the failure rate was 0% (0/119), the upper limit of the 95% confidence interval of the failure rate was 3.1%, and 30% (119/395) of the CTPA might be omitted.ConclusionThe new d-dimer threshold could safely exclude PE. This result can be generalized to other Asian populations with a lower incidence of PE. Further prospective studies will be needed.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] D-dimer test in cancer patients with suspected acute pulmonary embolism
    Di Nisio, M
    Sohne, M
    Kamphuisen, PW
    Büller, HR
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2005, 3 (06) : 1239 - 1242
  • [12] Use of D-dimer for the exclusion of new pulmonary embolism in anticoagulated patients: A multicenter retrospective study
    Beaudoin, Etienne
    Kaka, Shaima
    Gagnon, Elisabeth
    Duriyage, Andreanne
    Boulais, Isabelle
    Le Templier, Genevieve
    Toupin, Dominique
    Le Gal, Gregoire
    Gouin, Bobby
    THROMBOSIS RESEARCH, 2022, 212 : 19 - 21
  • [13] Diagnostic accuracy of D-dimer assay in suspected pulmonary embolism patients
    Youssf, Abdel Rahem I.
    Ismail, Mohammed F. M.
    ElGhamry, Reda
    Reyad, Mahmoud R.
    EGYPTIAN JOURNAL OF CHEST DISEASES AND TUBERCULOSIS, 2014, 63 (02): : 411 - 417
  • [14] A fresh look at D-dimer in suspected pulmonary embolism
    Miller, A
    THORAX, 1998, 53 (10) : 821 - 822
  • [15] D-dimer testing for suspected pulmonary embolism in outpatients
    Perrier, A
    Desmarais, S
    Goehring, C
    deMoerloose, P
    Morabia, A
    Unger, PF
    Slosman, D
    Junod, A
    Bounameaux, H
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1997, 156 (02) : 492 - 496
  • [16] Plasma D-dimer levels in elderly patients with suspected pulmonary embolism
    Masotti, L
    Ceccarelli, E
    Cappelli, R
    Forconi, S
    THROMBOSIS RESEARCH, 2000, 98 (06) : 577 - 579
  • [17] PLASMA D-DIMER IN SUSPECTED PULMONARY-EMBOLISM
    SUREDA, A
    PASCUAL, J
    FRADE, LJG
    LANCET, 1991, 337 (8745): : 860 - 860
  • [18] YEARS rule combined with the age-adjusted d-dimer threshold in patients with suspected pulmonary embolism
    Piazza, Isabelle
    Passarella, Mariele
    Fornelli, Vincenzo
    Memaj, Irdi
    INTERNAL AND EMERGENCY MEDICINE, 2022, 17 (07) : 2141 - 2142
  • [19] YEARS rule combined with the age-adjusted d-dimer threshold in patients with suspected pulmonary embolism
    Isabelle Piazza
    Mariele Passarella
    Vincenzo Fornelli
    Irdi Memaj
    Internal and Emergency Medicine, 2022, 17 : 2141 - 2142
  • [20] Could D-dimer provide a definitive diagnosis in patients with suspected pulmonary embolism?
    Gibson, Nadine S.
    Bueller, Harry R.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2006, 3 (12): : 654 - 655