Digital coincidence acquisition applied to portable β liquid scintillation counting device

被引:0
|
作者
Ren Zhongguo [1 ,2 ]
Hu Bitao [1 ]
Zhao Zhiping [2 ]
Li Dongcang [1 ]
机构
[1] Lanzhou Univ, Sch Nucl Sci & Technol, Lanzhou 730000, Peoples R China
[2] China Acad Engn Phys, Mianyang 621907, Peoples R China
基金
中国国家自然科学基金;
关键词
Digitizer; Liquid scintillation; Coincidence;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A digital coincidence acquisition system applied to a portable liquid scintillation counting device is developed. The system which simplifies the device design consists of a digitizer card of Agilent U1066A DC438, a discriminator and a host computer. The anode analog pulses from two photomultiplier tubes are captured by the system, which adopts the sequence acquisition storage mode. By choosing proper threshold for each channel, coincidence time window of +/- 30 ns, and comparing the pulse amplitudes from two channels, the portable scintillation counting device can be used to detect beta particles. For the unquenched standard H-3 sample, the results show that the detection efficiency is (58.5 +/- 0.1)% and the background is (86.7 +/- 0.7) cpm. Meanwhile, H-3 beta spectrum is obtained.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] A Monte Carlo Model for Neutron Coincidence Counting with Fast Organic Liquid Scintillation Detectors
    Gamage, Kelum A. A.
    Joyce, Malcolm J.
    Cave, Frank D.
    2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [22] FASEA: A FPGA Acquisition System and Software Event Analysis for liquid scintillation counting
    Steele, T.
    Mo, L.
    Bignell, L.
    Smith, M.
    Alexiev, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 217 - 220
  • [23] CHEMILUMINESCENCE IN LIQUID SCINTILLATION COUNTING
    WOODS, AH
    OBAR, PR
    ANALYTICAL BIOCHEMISTRY, 1970, 36 (02) : 268 - &
  • [24] Cerenkov counting as a complement to liquid scintillation counting
    Scarpitta, SC
    Fisenne, IM
    APPLIED RADIATION AND ISOTOPES, 1996, 47 (08) : 795 - 800
  • [25] SIMPLIFIED LIQUID SCINTILLATION COUNTING
    BARBER, DE
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (04): : 687 - &
  • [26] SIMPLIFIED LIQUID SCINTILLATION COUNTING
    BARBER, DE
    HEALTH PHYSICS, 1969, 17 (02): : 375 - +
  • [27] LIQUID SCINTILLATION COUNTING OF BLOOD
    HOUTMAN, AC
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1965, 16 (02): : 65 - &
  • [28] LIQUID SCINTILLATION COUNTING OF RADIOAUTOGRAMS
    GEIGER, JW
    WRIGHT, LD
    BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1960, 2 (04) : 282 - 283
  • [29] LIQUID SCINTILLATION COUNTING OF RADIOIODINE
    RHODES, BA
    ANALYTICAL CHEMISTRY, 1965, 37 (8P1) : 995 - &
  • [30] Accurate activity measurement of Lu-177 by the liquid scintillation 4πβ-γ coincidence counting technique
    Simpson, B. R. S.
    van Staden, M. J.
    Lubbe, J.
    van Wyngaardt, W. M.
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 2209 - 2214