Digital coincidence acquisition applied to portable β liquid scintillation counting device

被引:0
|
作者
Ren Zhongguo [1 ,2 ]
Hu Bitao [1 ]
Zhao Zhiping [2 ]
Li Dongcang [1 ]
机构
[1] Lanzhou Univ, Sch Nucl Sci & Technol, Lanzhou 730000, Peoples R China
[2] China Acad Engn Phys, Mianyang 621907, Peoples R China
基金
中国国家自然科学基金;
关键词
Digitizer; Liquid scintillation; Coincidence;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
A digital coincidence acquisition system applied to a portable liquid scintillation counting device is developed. The system which simplifies the device design consists of a digitizer card of Agilent U1066A DC438, a discriminator and a host computer. The anode analog pulses from two photomultiplier tubes are captured by the system, which adopts the sequence acquisition storage mode. By choosing proper threshold for each channel, coincidence time window of +/- 30 ns, and comparing the pulse amplitudes from two channels, the portable scintillation counting device can be used to detect beta particles. For the unquenched standard H-3 sample, the results show that the detection efficiency is (58.5 +/- 0.1)% and the background is (86.7 +/- 0.7) cpm. Meanwhile, H-3 beta spectrum is obtained.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] The validation of a digital coincidence counting system
    Buckman, SM
    Keightley, JD
    Smith, D
    Woods, MJ
    APPLIED RADIATION AND ISOTOPES, 1998, 49 (9-11) : 1135 - 1140
  • [32] Digital coincidence counting for radionuclide standardization
    Keightley, John
    Park, Tae Soon
    METROLOGIA, 2007, 44 (04) : S32 - S35
  • [33] Digital coincidence counting - initial results
    Butcher, KSA
    Watt, GC
    Alexiev, D
    van der Gaast, H
    Davies, J
    Mo, L
    Wyllie, HA
    Keightley, JD
    Smith, D
    Woods, MJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 450 (01): : 30 - 34
  • [34] A portable liquid scintillation counter for general LSC and high sensitivity alpha-counting applications
    Haaslahti, J
    Aalto, J
    Oikari, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 243 (02) : 377 - 381
  • [35] A Portable Liquid Scintillation Counter for General LSC and High Sensitivity Alpha-Counting Applications
    J. Haaslahti
    J. Aalto
    T. Oikari
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 243 : 377 - 381
  • [36] Standardization of 139Ce by the liquid scintillation counting using the triple to double coincidence ratio method
    Radioisotope Cent, Otwock-Swierk, Poland
    Appl Radiat Isot, 9-11 (1035-1040):
  • [37] THE ENHANCED TRIPLE TO DOUBLE COINCIDENCE RATIO (ETDCR) METHOD FOR STANDARDIZATION OF RADIONUCLIDES BY LIQUID SCINTILLATION-COUNTING
    BRODA, R
    POCHWALSKI, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 312 (1-2): : 85 - 89
  • [38] Digital Coincidence System for beta-gamma Coincidence Counting
    Yuan Daqing
    Liu QiZhi
    Yang Yuandi
    Wang Jianqing
    Chen YunDong
    Liang JunChen
    Chen Xilin
    Yao Shunhe
    Guo Xiaoqing
    Wu Yongle
    NUCLEAR PHYSICS A, 2010, 834 (1-4) : 773C - 776C
  • [39] A simple method for determination of 226Ra in environmental samples by applying α-β coincidence liquid scintillation counting
    Sato, K
    Hashimoto, T
    Noguchi, M
    Nitta, W
    Higuchi, H
    Nishikawa, N
    Sanada, T
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2000, 48 (02) : 247 - 256
  • [40] WINDOWLESS MEASUREMENT OF COUNTING RATE AT LIQUID SCINTILLATION COUNTING
    KACZMARCZYK, N
    RUGE, I
    ATOMPRAXIS, 1968, 14 (9-10): : 391 - +