Evaluation of a novel personal nanoparticle sampler

被引:7
|
作者
Zhou, Yue [1 ]
Irshad, Hammad [1 ]
Tsai, Chuen-Jinn [2 ]
Hung, Shao-Ming [2 ]
Cheng, Yung-Sung [1 ]
机构
[1] Lovelace Resp Res Inst, Albuquerque, NM 87108 USA
[2] NCTU, Hsinchu, Taiwan
关键词
INHALABLE AEROSOL SAMPLERS; ULTRAFINE PARTICLES; DEPOSITION; EXPOSURE; PERFORMANCE; AIRWAYS; CALIBRATION; WORKPLACES; EFFICIENCY; CHILDREN;
D O I
10.1039/c3em00497j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work investigated the performance in terms of collection efficiency and aspiration efficiency of a personal sampler capable of collecting ultrafine particles (nanoparticles) in the occupational environment. This sampler consists of a cyclone for respirable particle classification, micro-orifice impactor stages with an acceleration nozzle to achieve nanoparticle classification and a backup filter to collect nanoparticles. Collection efficiencies of the cyclone and impactor stages were determined using monodisperse polystyrene latex and silver particles, respectively. Calibration of the cyclone and impactor stages showed 50% cut-off diameters of 3.95 mu m and 94.7 nm meeting the design requirements. Aspiration efficiencies of the sampler were tested in a wind tunnel with wind speeds of 0.5, 1.0, and 1.5 m s(-1). The test samplers were mounted on a full size mannequin with three orientations toward the wind direction (0 degrees, 90 degrees, and 180 degrees). Monodisperse oleic acid aerosols tagged with sodium fluorescein in the size range of 2 to 10 mu m were used in the test. For particles smaller than 2 mu m, the fluorescent polystyrene latex particles were generated by using nebulizers. For comparison of the aspiration efficiency, a NIOSH two-stage personal bioaerosol sampler was also tested. Results showed that the orientation-averaged aspiration efficiency for both samplers was close to the inhalable fraction curve. However, the direction of wind strongly affected the aspiration efficiency. The results also showed that the aspiration efficiency was not affected by the ratio of free-stream velocity to the velocity through the sampler orifice. Our evaluation showed that the current design of the personal sampler met the designed criteria for collecting nanoparticles <= 100 nm in occupational environments.
引用
收藏
页码:203 / 210
页数:8
相关论文
共 50 条
  • [31] THE DEVELOPMENT OF A REVOLVING PERSONAL SAMPLER
    KUMAGAI, S
    MATSUNAGA, I
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1992, 53 (04): : 261 - 264
  • [32] Design and evaluation of a high-flowrate nanoparticle respiratory deposition (NRD)sampler
    Szabo McCollom, Theresa I.
    Stebounova, Larissa V.
    Park, Jae Hong
    Grassian, Vicki H.
    Gonzalez-Pech, Natalia I.
    Peters, Thomas M.
    Journal of Aerosol Science, 2019, 134 : 72 - 79
  • [33] Design and evaluation of a high-flowrate nanoparticle respiratory deposition (NRD) sampler
    McCollom, Theresa I. Szabo
    Stebounova, Larissa V.
    Park, Jae Hong
    Grassian, Vicki H.
    Gonzalez-Pech, Natalia I.
    Peters, Thomas M.
    JOURNAL OF AEROSOL SCIENCE, 2019, 134 : 72 - 79
  • [34] Initial field evaluation of the Harvard active ozone sampler for personal ozone monitoring
    Geyh, AS
    Roberts, PT
    Lurmann, FW
    Schoell, BM
    Avol, EL
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 1999, 9 (02): : 143 - 149
  • [35] Initial field evaluation of the Harvard active ozone sampler for personal ozone monitoring
    ALISON S GEYH
    PAUL T ROBERTS
    FREDERICK W LURMANN
    BASTIAN M SCHOELL
    EDWARD L AVOL
    Journal of Exposure Science & Environmental Epidemiology, 1999, 9 : 143 - 149
  • [36] Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces
    Bohlin, Pernilla
    Jones, Kevin C.
    Levin, Jan-Olof
    Lindahl, Roger
    Strandberg, Bo
    JOURNAL OF ENVIRONMENTAL MONITORING, 2010, 12 (07): : 1437 - 1444
  • [37] LOCATION OF PERSONAL SAMPLER FILTER HEADS
    CHATTERJEE, BB
    WILLIAMS, MK
    WALFORD, J
    KING, E
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1969, 30 (06): : 643 - +
  • [38] A Personal, Thermophoretic Sampler for Airborne Nanoparticles
    Thayer, D.
    Koehler, K. A.
    Marchese, A.
    Volckens, J.
    AEROSOL SCIENCE AND TECHNOLOGY, 2011, 45 (06) : 744 - 750
  • [39] PERSONAL SAMPLER FOR NITROGEN-DIOXIDE
    PALMES, ED
    GUNNISON, AF
    DIMATTIO, J
    TOMCZYK, C
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1976, 37 (10): : 570 - 577
  • [40] A PERSONAL SAMPLER FOR 3 RESPIRATORY IRRITANTS
    MINTZ, S
    HOSEIN, HR
    BATTEN, B
    SILVERMAN, F
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1982, 32 (10): : 1068 - 1069