Field evaluation of a passive personal air sampler for screening of PAH exposure in workplaces

被引:31
|
作者
Bohlin, Pernilla [1 ]
Jones, Kevin C. [2 ]
Levin, Jan-Olof [3 ]
Lindahl, Roger [3 ]
Strandberg, Bo [1 ]
机构
[1] Univ Gothenburg, Dept Occupat & Environm Med, Sahlgrenska Acad, Gothenburg, Sweden
[2] Univ Lancaster, Ctr Chem Management, Lancaster LA1 4YQ, England
[3] Umea Univ, Dept Chem, SE-90187 Umea, Sweden
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2010年 / 12卷 / 07期
基金
英国自然环境研究理事会;
关键词
POLYCYCLIC AROMATIC-HYDROCARBONS; PERSISTENT ORGANIC POLLUTANTS; PERFORMANCE ASSESSMENT; DEPURATION COMPOUNDS; DIFFUSIVE SAMPLERS; OUTDOOR AIR; CANCER-RISK; INDOOR; RATES; ENVIRONMENTS;
D O I
10.1039/c0em00018c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New sampling methods are needed to simplify and enable frequent monitoring of workers' exposure to polycyclic aromatic hydrocarbons (PAHs). The sampler needs to fulfil some key operational requirements for occupational exposure assessments: (i) be useable as a personal sampler; (ii) work over 8 h exposure time; (iii) sequester PAHs both in gas and particle phase, (iv) yield reliable estimates of air concentrations. Here, a new smaller design of the traditional polyurethane foam (PUF) passive air sampler (PAS) (i.e. a 'mini-PUF') was introduced and assessed against these requirements in sites with elevated PAH concentrations. The exposure times were 2 weeks and 8 hours. The obtained sampling rates (R-values) were not significantly different between gas phase (0.4-3.3 m(3) day(-1), 0.3-2.3 L min(-1)) and particle associated PAHs (0.5-1.9 m(3) day(-1), 0.4-1.3 L min(-1)). The accuracy in estimating air concentrations was within +/- 25% from the active sampler for half of the PAHs for the mini-PUF under 8 h exposures. Significant correlations (p < 0.003) were found between personally deployed mini-PUFs and a co-deployed personal active sampling method. This together with the low costs and ease-of-use of the mini-PUF encourage application in exposure assessments.
引用
收藏
页码:1437 / 1444
页数:8
相关论文
共 50 条
  • [1] MEASUREMENT OF PERSONAL EXPOSURE TO NO2 IN SWEDEN - EVALUATION OF A PASSIVE SAMPLER
    BERGLUND, M
    VAHTER, M
    BYLIN, G
    JOURNAL OF EXPOSURE ANALYSIS AND ENVIRONMENTAL EPIDEMIOLOGY, 1992, 2 (03): : 295 - 307
  • [2] Evaluation of polyurethane foam passive air sampler (PUF) as a tool for occupational PAH measurements
    Strandberg, Bo
    Julander, Anneli
    Sjostrom, Mattias
    Lewne, Marie
    Akdeva, Hatice Koca
    Bigert, Carolina
    CHEMOSPHERE, 2018, 190 : 35 - 42
  • [3] Novel Active Personal Nanoparticle Sampler for the Exposure Assessment of Nanoparticles in Workplaces
    Tsai, Chuen-Jinn
    Liu, Chun-Nan
    Hung, Shao-Ming
    Chen, Sheng-Chieh
    Uang, Shi-Nian
    Cheng, Yung-Sung
    Zhou, Yue
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (08) : 4546 - 4552
  • [4] Field evaluation of a passive sampler for the exposure assessment of 2-methoxyethanol
    T.-S. Shih
    C.-Y. Chen
    R.-I. Cheng
    L.-J. Wu
    International Archives of Occupational and Environmental Health, 2000, 73 : 98 - 104
  • [5] Field evaluation of a passive sampler for the exposure assessment of 2-methoxyethanol
    Shih, TS
    Chen, CY
    Cheng, RI
    Wu, LJ
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2000, 73 (02) : 98 - 104
  • [6] Field evaluation of a personal, bioaerosol cyclone sampler
    Macher, Janet
    Chen, Bean
    Rao, Carol
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2008, 5 (11) : 724 - 734
  • [7] A field evaluation of a SO2 passive sampler in tropical industrial and urban air
    Cruz, LPS
    Campos, VP
    Silva, AMC
    Tavares, TM
    ATMOSPHERIC ENVIRONMENT, 2004, 38 (37) : 6425 - 6429
  • [8] Evaluation of a passive air sampler for measuring indoor formaldehyde
    Kim, Sun-Tae
    Yim, Bongbeen
    Jeong, Jaeho
    ANALYTICAL SCIENCES, 2007, 23 (04) : 497 - 500
  • [9] Evaluation of a Passive Air Sampler for Measuring Indoor Formaldehyde
    Sun-Tae Kim
    Bongbeen Yim
    Jaeho Jeong
    Analytical Sciences, 2007, 23 : 497 - 500
  • [10] Field Evaluation of the Ultrasonic Personal Aerosol Sampler (UPAS) for Respirable Dust Exposure in a Taconite Mine
    Afshar-Mohajer, Nima
    Foos, Rebecca
    Ramachandran, Gurumurthy
    Volckens, John
    ANNALS OF WORK EXPOSURES AND HEALTH, 2021, 65 (01) : 127 - 135