Comparison of Skull Radiograph and Computed Tomography Measurements of Cochlear Implant Insertion Angles

被引:10
|
作者
Gallant, Sara [1 ]
Friedmann, David R. [1 ]
Hagiwara, Mari [2 ]
Roland, J. Thomas, Jr. [1 ]
Svirsky, Mario A. [1 ]
Jethanamest, Daniel [1 ]
机构
[1] NYU, Sch Med, Dept Otolaryngol, New York, NY 10003 USA
[2] NYU, Sch Med, Dept Radiol, New York, NY 10003 USA
关键词
Angular depth of insertion; Cochlear implant; Cochlear implant imaging; POSITION;
D O I
10.1097/MAO.0000000000002121
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Measurement of the angular depth of insertion (aDOI) of cochlear implant electrode arrays has numerous clinical and research applications. Plain-film radiographs are easily obtained intraoperatively and have been described as a means to calculate aDOI. CT imaging with 3D reformatting can also be used for this measurement, but is less conveniently obtained and requires higher radiation doses, a particular concern in pediatrics. The extent to which plain-film and 3D CT image-based measurements are representative of the true position of the electrode within the cochlea is unknown. Methods: Cochlear implantation was performed on 10 cadaveric temporal bones. Five bones were implanted with perimodiolar electrodes (Contour Advance TM, Cochlear, Sydney, Australia) and five were implanted with lateral wall electrodes (Slim Straight, Cochlear). The insertion depths of the electrodes were varied. Each bone was imaged with a radiograph and CT. aDOI was measured for each bone in each imaging modality by a neurotologist and a neuroradiologist. To obtain a "gold standard" estimate of aDOI, the implanted temporal bones were embedded in an epoxy resin and methodically sectioned at 100 mm intervals; histologic images were captured at each interval. A 3D stack of the images was compounded, and a MATLAB script used to calculate aDOI of the most apical electrode. Measurements in the three modalities (radiograph, CT, and histology) were then compared. Results: The average aDOI across all bones was similar for all modalities: 4238 for radiographs, 4258 for CT scans, and 4278 for histology, indicating that neither imaging modality resulted in large systematic errors. Using the histology-measured angles as a reference, the average error for CT-based measures (regardless of whether the error was in the positive or negative direction) was 128, and that for radiograph-based measures was 158. This small difference (12 vs 158 error) was not statistically significant. Conclusion: Based on this cadaveric temporal bone model, both radiographs and CTs can provide reasonably accurate aDOI measurements. In this small sample, and as expected, the CT-based estimates were more accurate than the radiograph-based measurements. However, the difference was small and not statistically significant. Thus, the use of plain radiographs to calculate aDOI seems judicious whenever it is desired to prevent unnecessary radiation exposure and expense.
引用
收藏
页码:E298 / E303
页数:6
相关论文
共 50 条
  • [21] Comparison of Tracheal Diameter Measurements on Radiograph Versus Computed Tomography at a Tertiary Care Hospital in Pune, Central India
    Ajmera, Pranav
    Prasad, Niharika
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (03)
  • [22] HIGH-RESOLUTION COMPUTED-TOMOGRAPHY IN EVALUATION OF COCHLEAR PATENCY IN IMPLANT CANDIDATES - A COMPARISON WITH SURGICAL FINDINGS
    FRAU, GN
    LUXFORD, WM
    LO, WWM
    BERLINER, KI
    TELISCHI, FF
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1994, 108 (09): : 743 - 748
  • [23] A retrospective analysis of high resolution computed tomography in the assessment of cochlear implant patients
    Nair, SB
    Abou-Elhamd, KA
    Hawthorne, M
    CLINICAL OTOLARYNGOLOGY, 2000, 25 (01) : 55 - 61
  • [24] Optimising the parameters of cochlear implant imaging with cone-beam computed tomography
    Soederqvist, Samuel
    Sivonen, Ville
    Aarnisalo, Antti
    Karppi, Harri
    Sinkkonen, Saku T.
    Koivisto, Juha
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (05) : 462 - 470
  • [25] Audiological correlates of cone beam computed tomography (CBCT) in cochlear implant recipients
    Rahman, Tayseer Taha Abdel
    Kader, Hesham Abd El Aty Abdel
    Aziz, Tougan Taha Abdel
    HEARING BALANCE AND COMMUNICATION, 2019, 17 (04) : 249 - 256
  • [26] The evaluation of palatal bone thickness for implant insertion with cone beam computed tomography
    Sumer, A. P.
    Caliskan, A.
    Uzun, C.
    Karoz, T. B.
    Sumer, M.
    Cankaya, S.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (02) : 216 - 220
  • [27] CT and MR Imaging Cochlear Distance Measurements May Predict Cochlear Implant Length Required for a 360° Insertion
    Connor, S. E. J.
    Bell, D. J.
    O'Gorman, R.
    Fitzgerald-O'Connor, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (07) : 1425 - 1430
  • [28] Force measurement of insertion of cochlear implant electrode arrays in vitro: comparison of surgeon to automated insertion tool
    Majdani, Omid
    Schurzig, Daniel
    Hussong, Andreas
    Rau, Thomas
    wittkopf, Justin
    Lenarz, Thomas
    Labadie, Robert F.
    ACTA OTO-LARYNGOLOGICA, 2010, 130 (01) : 31 - 36
  • [29] A Micro-computed Study of Round Window Anatomy and Implications for Atraumatic Cochlear Implant Insertion
    Cornwall, Hannah Louisa
    Marway, Prabhvir Singh
    Bance, Manohar
    OTOLOGY & NEUROTOLOGY, 2021, 42 (02) : 327 - 334
  • [30] Automatic localization of cochlear implant electrodes using cone beam computed tomography images
    Thormaehlen, Jasmin
    Krueger, Benjamin
    Nogueira, Waldo
    BIOMEDICAL ENGINEERING ONLINE, 2024, 23 (01)