Comparison of Skull Radiograph and Computed Tomography Measurements of Cochlear Implant Insertion Angles

被引:10
|
作者
Gallant, Sara [1 ]
Friedmann, David R. [1 ]
Hagiwara, Mari [2 ]
Roland, J. Thomas, Jr. [1 ]
Svirsky, Mario A. [1 ]
Jethanamest, Daniel [1 ]
机构
[1] NYU, Sch Med, Dept Otolaryngol, New York, NY 10003 USA
[2] NYU, Sch Med, Dept Radiol, New York, NY 10003 USA
关键词
Angular depth of insertion; Cochlear implant; Cochlear implant imaging; POSITION;
D O I
10.1097/MAO.0000000000002121
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Measurement of the angular depth of insertion (aDOI) of cochlear implant electrode arrays has numerous clinical and research applications. Plain-film radiographs are easily obtained intraoperatively and have been described as a means to calculate aDOI. CT imaging with 3D reformatting can also be used for this measurement, but is less conveniently obtained and requires higher radiation doses, a particular concern in pediatrics. The extent to which plain-film and 3D CT image-based measurements are representative of the true position of the electrode within the cochlea is unknown. Methods: Cochlear implantation was performed on 10 cadaveric temporal bones. Five bones were implanted with perimodiolar electrodes (Contour Advance TM, Cochlear, Sydney, Australia) and five were implanted with lateral wall electrodes (Slim Straight, Cochlear). The insertion depths of the electrodes were varied. Each bone was imaged with a radiograph and CT. aDOI was measured for each bone in each imaging modality by a neurotologist and a neuroradiologist. To obtain a "gold standard" estimate of aDOI, the implanted temporal bones were embedded in an epoxy resin and methodically sectioned at 100 mm intervals; histologic images were captured at each interval. A 3D stack of the images was compounded, and a MATLAB script used to calculate aDOI of the most apical electrode. Measurements in the three modalities (radiograph, CT, and histology) were then compared. Results: The average aDOI across all bones was similar for all modalities: 4238 for radiographs, 4258 for CT scans, and 4278 for histology, indicating that neither imaging modality resulted in large systematic errors. Using the histology-measured angles as a reference, the average error for CT-based measures (regardless of whether the error was in the positive or negative direction) was 128, and that for radiograph-based measures was 158. This small difference (12 vs 158 error) was not statistically significant. Conclusion: Based on this cadaveric temporal bone model, both radiographs and CTs can provide reasonably accurate aDOI measurements. In this small sample, and as expected, the CT-based estimates were more accurate than the radiograph-based measurements. However, the difference was small and not statistically significant. Thus, the use of plain radiographs to calculate aDOI seems judicious whenever it is desired to prevent unnecessary radiation exposure and expense.
引用
收藏
页码:E298 / E303
页数:6
相关论文
共 50 条
  • [11] A comparison of various angles of halo pin insertion in an immature skull model
    Copley, LAB
    Pepe, MD
    Tan, V
    Dormans, JP
    SPINE, 1999, 24 (17) : 1777 - 1780
  • [12] Insertion Depth Angles of Cochlear Implant Arrays With Varying Length: A Temporal Bone Study
    Franke-Trieger, Annett
    Jolly, Claude
    Darbinjan, Alexander
    Zahnert, Thomas
    Muerbe, Dirk
    OTOLOGY & NEUROTOLOGY, 2014, 35 (01) : 58 - 63
  • [13] An Accurate and Individualized Preoperative Estimation Method for the Linear Insertion Depth of Cochlear Implant Electrode Arrays Based on Computed Tomography
    Jia, Gaogan
    Song, Zijun
    Wu, Lingjie
    Sun, Qiushi
    Sheng, Yaru
    Ni, Yusu
    Li, Huawei
    Li, Wenyan
    EAR AND HEARING, 2023, 44 (05): : 1036 - 1042
  • [14] Computed-Tomography Estimates of Interaural Mismatch in Insertion Depth and Scalar Location in Bilateral Cochlear-Implant Users
    Goupell, Matthew J.
    Noble, Jack H.
    Phatak, Sandeep A.
    Kolberg, Elizabeth
    Cleary, Miranda
    Stakhovskaya, Olga A.
    Jensen, Kenneth K.
    Hoa, Michael
    Kim, Hung Jeffrey
    Bernstein, Joshua G. W.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (06) : 666 - 675
  • [15] Preclinical evaluation of a tool for insertion force measurements in cochlear implant surgery
    Boettcher-Rebmann, Georg
    Schell, Viktor
    Zuniga, M. Geraldine
    Salcher, Rolf
    Lenarz, Thomas
    Rau, Thomas S.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (11) : 2117 - 2124
  • [16] Preclinical evaluation of a tool for insertion force measurements in cochlear implant surgery
    Georg Böttcher-Rebmann
    Viktor Schell
    M. Geraldine Zuniga
    Rolf Salcher
    Thomas Lenarz
    Thomas S. Rau
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 2117 - 2124
  • [17] A Tool to Enable Intraoperative Insertion Force Measurements for Cochlear Implant Surgery
    Boettcher-Rebmann, Georg
    Schell, Viktor
    Budde, Leon
    Zuniga, M. Geraldine
    Baier, Claas
    Lenarz, Thomas
    Rau, Thomas S. S.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (05) : 1643 - 1650
  • [18] Evaluation of artifacts of cochlear implant electrodes in cone beam computed tomography
    Nicholas Bevis
    Thomas Effertz
    Dirk Beutner
    Christian Gueldner
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 1381 - 1386
  • [19] Evaluation of artifacts of cochlear implant electrodes in cone beam computed tomography
    Bevis, Nicholas
    Effertz, Thomas
    Beutner, Dirk
    Gueldner, Christian
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (05) : 1381 - 1386
  • [20] Computed Tomography Estimation of Cochlear Duct Length Can Predict Full Insertion in Cochlear Implantation
    Johnston, James D. A.
    Scoffings, Daniel
    Chung, Mark
    Baguley, David
    Donnelly, Neil P.
    Axon, Patrick R.
    Gray, Roger F.
    Tysome, James R.
    OTOLOGY & NEUROTOLOGY, 2016, 37 (03) : 223 - 228