Comparison of Skull Radiograph and Computed Tomography Measurements of Cochlear Implant Insertion Angles

被引:10
|
作者
Gallant, Sara [1 ]
Friedmann, David R. [1 ]
Hagiwara, Mari [2 ]
Roland, J. Thomas, Jr. [1 ]
Svirsky, Mario A. [1 ]
Jethanamest, Daniel [1 ]
机构
[1] NYU, Sch Med, Dept Otolaryngol, New York, NY 10003 USA
[2] NYU, Sch Med, Dept Radiol, New York, NY 10003 USA
关键词
Angular depth of insertion; Cochlear implant; Cochlear implant imaging; POSITION;
D O I
10.1097/MAO.0000000000002121
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Measurement of the angular depth of insertion (aDOI) of cochlear implant electrode arrays has numerous clinical and research applications. Plain-film radiographs are easily obtained intraoperatively and have been described as a means to calculate aDOI. CT imaging with 3D reformatting can also be used for this measurement, but is less conveniently obtained and requires higher radiation doses, a particular concern in pediatrics. The extent to which plain-film and 3D CT image-based measurements are representative of the true position of the electrode within the cochlea is unknown. Methods: Cochlear implantation was performed on 10 cadaveric temporal bones. Five bones were implanted with perimodiolar electrodes (Contour Advance TM, Cochlear, Sydney, Australia) and five were implanted with lateral wall electrodes (Slim Straight, Cochlear). The insertion depths of the electrodes were varied. Each bone was imaged with a radiograph and CT. aDOI was measured for each bone in each imaging modality by a neurotologist and a neuroradiologist. To obtain a "gold standard" estimate of aDOI, the implanted temporal bones were embedded in an epoxy resin and methodically sectioned at 100 mm intervals; histologic images were captured at each interval. A 3D stack of the images was compounded, and a MATLAB script used to calculate aDOI of the most apical electrode. Measurements in the three modalities (radiograph, CT, and histology) were then compared. Results: The average aDOI across all bones was similar for all modalities: 4238 for radiographs, 4258 for CT scans, and 4278 for histology, indicating that neither imaging modality resulted in large systematic errors. Using the histology-measured angles as a reference, the average error for CT-based measures (regardless of whether the error was in the positive or negative direction) was 128, and that for radiograph-based measures was 158. This small difference (12 vs 158 error) was not statistically significant. Conclusion: Based on this cadaveric temporal bone model, both radiographs and CTs can provide reasonably accurate aDOI measurements. In this small sample, and as expected, the CT-based estimates were more accurate than the radiograph-based measurements. However, the difference was small and not statistically significant. Thus, the use of plain radiographs to calculate aDOI seems judicious whenever it is desired to prevent unnecessary radiation exposure and expense.
引用
收藏
页码:E298 / E303
页数:6
相关论文
共 50 条
  • [1] In Vivo Measurements of the Insertion Depth of Cochlear Implant Arrays Using Flat-Panel Volume Computed Tomography
    Trieger, Annett
    Schulze, Anja
    Schneider, Matthias
    Zahnert, Thomas
    Muerbe, Dirk
    OTOLOGY & NEUROTOLOGY, 2011, 32 (01) : 152 - 157
  • [2] Predicting Depth of Electrode Insertion by Cochlear Measurements on Computed Tomography Scans
    Angeli, Simon I.
    Goncalves, Stefania
    LARYNGOSCOPE, 2016, 126 (07): : 1656 - 1661
  • [3] Scalar Localization by Computed Tomography of Cochlear Implant Electrode Carriers Designed for Deep Insertion
    Helbig, Silke
    Mack, Martin
    Schell, Boris
    Bratzke, Hansjuergen
    Stoever, Timo
    Helbig, Matthias
    OTOLOGY & NEUROTOLOGY, 2012, 33 (05) : 745 - 750
  • [4] Computed Tomography-Based Measurements of the Cochlear Duct: Implications for Cochlear Implant Pitch Tuning
    Jiam, Nicole T.
    Gilbert, Melanie
    Mo, Jonathan
    Jiradejvong, Patpong
    Limb, Charles J.
    EAR AND HEARING, 2021, 42 (03): : 732 - 743
  • [5] Cochlear implants: Insertion assessment by computed tomography
    Menegatti Pavan, Ana Luiza
    Fattori Alves, Allan Felipe
    Giacomini, Guilherme
    Carrasco Altemani, Joao Mauricio
    Castilho, Arthur Menino
    Lauria, Raquel Andrade
    Rodrigues da Silva, Vagner Antonio
    Guimaraes, Alexandre Caixeta
    de Pina, Diana Rodrigues
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2018, 39 (04) : 431 - 435
  • [6] QUANTIFICATION OF IMPORTANT MEASUREMENTS OF THE PETROUS BONE IN COMPUTED-TOMOGRAPHY PRECEDING COCHLEAR IMPLANT
    MAHER, N
    BECKER, H
    LASZIG, R
    LARYNGO-RHINO-OTOLOGIE, 1995, 74 (06) : 337 - 342
  • [7] The limitations of computed tomography in adult cochlear implant evaluation
    Sweeney, Alex D.
    Carlson, Matthew L.
    Rivas, Alejandro
    Bennett, Marc L.
    Haynes, David S.
    Wanna, George B.
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2014, 35 (03) : 396 - 399
  • [8] Effectiveness of skull X-RAY to determine cochlear implant insertion depth
    Vinay Fernandes
    Yiqiao Wang
    Robert Yeung
    Sean Symons
    Vincent Lin
    Journal of Otolaryngology - Head & Neck Surgery, 47
  • [9] Effectiveness of skull X-RAY to determine cochlear implant insertion depth
    Fernandes, Vinay
    Wang, Yiqiao
    Yeung, Robert
    Symons, Sean
    Lin, Vincent
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2018, 47
  • [10] BASE OF SKULL - COMPARISON OF COMPUTED AND CONVENTIONAL TOMOGRAPHY
    BECKER, H
    GRAU, H
    HACKER, H
    PLODER, KW
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (01) : 113 - 118