The accuracy of free-hand cup positioning -: a CT based measurement of cup placement in 105 total hip arthroplasties

被引:138
|
作者
Saxler, G
Marx, A
Vandevelde, D
Langlotz, U
Tannast, M
Wiese, M
Michaelis, U
Kemper, G
Grützner, PA
Steffen, R
von Knoch, M
Holland-Letz, T
Bernsmann, K
机构
[1] Univ Duisburg Essen, Dept Orthopaed Surg, D-45122 Essen, Germany
[2] Eeuwfeestklin Antwerpen, Dept Orthopaed Surg, B-2100 Deurne, Belgium
[3] Medivision, CH-4436 Oberdorf, Switzerland
[4] Univ Bern, Dept Orthopaed Surg, CH-3010 Bern, Switzerland
[5] Ruhr Univ Bochum, Dept Orthopaed Surg, D-44791 Bochum, Germany
[6] Alfried Krupp Krankenhaus Essen, Dept Orthopaed Surg, D-45117 Essen, Germany
[7] Dept Surg, D-42109 Wuppertal, Germany
[8] Heidelberg Univ, BG Unfallklin Ludwigshafen, Dept Traumatol, D-67071 Ludwigshafen, Germany
[9] Marienkrankenhaus Kaiserswerth, Dept Orthopaed Surg, D-40348 Dusseldorf, Germany
[10] Ruhr Univ Bochum, Dept Med Informat Biometr & Epidemiol, D-44801 Bochum, Germany
[11] Girardet Klin Essen, Dept Orthopaed Surg, D-45131 Essen, Germany
关键词
D O I
10.1007/s00264-004-0542-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We studied 105 patients who received a total hip arthroplasty between June 1985 and August 2001 using freehand positioning of the acetabular cup. Using pelvic CT scan and the hip-plan module of SurgiGATE-System (Medivision, Oberdorf, Switzerland), we measured the angles of inclination and anteversion of the cup. Mean inclination angle was 45.8degrees+/-10.1degrees (range: 23.0-71.5degrees) and mean anteversion angle was 27.3degrees+/-15.0degrees (range: -23.5degrees to 59.0degrees). We compared the results to the "safe" position as defined by Lewinnek et al. and found that only 27/105 cups were implanted within the limits of the safe position. We conclude that a safe position as defined by Lewinnek et al. [13] was only achieved in a minority of the cups that were implanted freehand.
引用
收藏
页码:198 / 201
页数:4
相关论文
共 50 条
  • [1] The accuracy of free-hand cup positioning - a CT based measurement of cup placement in 105 total hip arthroplasties
    G. Saxler
    A. Marx
    D. Vandevelde
    U. Langlotz
    M. Tannast
    M. Wiese
    U. Michaelis
    G. Kemper
    P. A. Grützner
    R. Steffen
    M. von Knoch
    T. Holland-Letz
    K. Bernsmann
    International Orthopaedics, 2004, 28 : 198 - 201
  • [2] Comparison of free-hand and computer assisted cup placement in total hip arthroplasty -: a multi-center study
    Saxler, G
    Marx, A
    Vandevelde, D
    Langlotz, U
    Tannast, M
    Wiese, M
    Michaelis, U
    Kemper, G
    Grützner, PA
    Steffen, R
    von Knoch, M
    Holland-Letz, T
    Bernsmann, K
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2004, 142 (03): : 286 - 291
  • [3] Accuracy considerations in navigated cup placement for total hip arthroplasty
    mNemoscience, Übach-Palenberg, Germany
    不详
    不详
    不详
    不详
    不详
    Proc. Inst. Mech. Eng. Part H J. Eng. Med., 2007, 7 (739-753):
  • [4] Accuracy considerations in navigated cup placement for total hip arthroplasty
    Langlotz, U.
    Gr tzner, P. A.
    Bernsmann, K.
    Kowal, J. H.
    Tannast, M.
    Caversaccio, M.
    Nolte, L-P
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H7) : 739 - 753
  • [5] Computer assisted measurement of cup placement in total hip replacement
    Jaramaz, B
    DiGioia, AM
    Blackwell, M
    Nikou, C
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (354) : 70 - 81
  • [6] Accuracy of acetabular cup positioning in robotic-assisted total hip arthroplasty: a CT-based evaluation
    Singh, Ashish
    Kumar, Purushotam
    Kalyan, Kanukuntla
    Gundalli, Akash Chandrashekar
    Mane, Sudhir Shankar
    Swarnkar, Himanshu
    Singh, Lavanya
    SICOT-J, 2024, 10
  • [7] Poor accuracy of freehand cup positioning during total hip arthroplasty
    B. H. Bosker
    C. C. P. M. Verheyen
    W. G. Horstmann
    N. J. A. Tulp
    Archives of Orthopaedic and Trauma Surgery, 2007, 127 : 375 - 379
  • [8] Poor accuracy of freehand cup positioning during total hip arthroplasty
    Bosker, B. H.
    Verheyen, C. C. P. M.
    Horstmann, W. G.
    Tulp, N. J. A.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2007, 127 (05) : 375 - 379
  • [9] Evaluation of cup placement accuracy in computer assisted total hip arthroplasty
    Kaneta, Hiroki
    Shoji, Takeshi
    Ueki, Shinichi
    Morita, Hiroyuki
    Kozuma, Yosuke
    Adachi, Nobuo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2025, 145 (01)
  • [10] Accuracy of computer-assisted cup placement in total hip arthroplasty
    Jolles, BM
    Genoud, P
    Hoffmeyer, P
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 301 - 305