Radiation dose in neuroangiography using image noise reduction technology: a population study based on 614 patients

被引:73
|
作者
Soderman, Michael [1 ,2 ]
Mauti, Maria [3 ]
Boon, Sjirk [3 ]
Omar, Artur [4 ]
Marteinsdottir, Maria [4 ]
Andersson, Tommy [1 ,2 ]
Holmin, Staffan [1 ,2 ]
Hoornaert, Bart [3 ]
机构
[1] Karolinska Univ Hosp Solna, Karolinska Inst, Dept Clin Neurosci, S-17176 Stockholm, Sweden
[2] Karolinska Univ Hosp Solna, Dept Neuroradiol, S-17176 Stockholm, Sweden
[3] Philips Healthcare, Best, Netherlands
[4] Karolinska Univ Hosp, Sect Imaging Phys, Dept Med Phys, Stockholm, Sweden
关键词
Angiography; Radiation dose; Radiation physics; Imaging technology; Interventional neuroradiology; INTERVENTIONAL NEURORADIOLOGY; EXPOSURE;
D O I
10.1007/s00234-013-1276-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The purpose of this study was to quantify the reduction in patient radiation dose by X-ray imaging technology using image noise reduction and system settings for neuroangiography and to assess its impact on the working habits of the physician. Radiation dose data from 190 neuroangiographies and 112 interventional neuroprocedures performed with state-of-the-art image processing and reference system settings were collected for the period January-June 2010. The system was then configured with extra image noise reduction algorithms and system settings, which enabled radiation dose reduction without loss of image quality. Radiation dose data from 174 neuroangiographies and 138 interventional neuroprocedures were collected for the period January-June 2012. Procedures were classified as diagnostic or interventional. Patient radiation exposure was quantified using cumulative dose area product and cumulative air kerma. Impact on working habits of the physician was quantified using fluoroscopy time and number of digital subtraction angiography (DSA) images. The optimized system settings provided significant reduction in dose indicators versus reference system settings (p < 0.001): from 124 to 47 Gy cm(2) and from 0.78 to 0.27 Gy for neuroangiography, and from 328 to 109 Gy cm(2) and from 2.71 to 0.89 Gy for interventional neuroradiology. Differences were not significant between the two systems with regard to fluoroscopy time or number of DSA images. X-ray imaging technology using an image noise reduction algorithm and system settings provided approximately 60% radiation dose reduction in neuroangiography and interventional neuroradiology, without affecting the working habits of the physician.
引用
收藏
页码:1365 / 1372
页数:8
相关论文
共 50 条
  • [41] Coronary CT Angiography in Obese Patients: Comparison of Iterative Reconstruction and Filtered Back Projection for Their Effect on Image Noise and Potential for Radiation Dose Reduction
    Joshi, G.
    Schoepf, U.
    Spears, Reid J.
    Mills, J.
    Vliegenthart, R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [42] Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method
    Yu, Lifeng
    Fletcher, Joel G.
    Shiung, Maria
    Thomas, Kristen B.
    Matsumoto, Jane M.
    Zingula, Shannon N.
    McCollough, Cynthia H.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 1026 - 1037
  • [43] Study of Pediatric CR Dose Reduction Using Noise Addition Simulations Tools
    Juste, B.
    Villaescusa, J. I.
    Tortosa, R.
    Verdu, G.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 879 - 882
  • [44] A STUDY ON OPTIMAL SCAN CONDITIONS OF BIG BORE MULTI-SLICE COMPUTED TOMOGRAPHY BASED ON RADIATION DOSE AND IMAGE NOISE
    Lee, Jae-Seong
    Ye, Sung-Joon
    Kim, Eun-Hee
    RADIATION PROTECTION DOSIMETRY, 2011, 146 (1-3) : 237 - 240
  • [45] Remote sensing image noise reduction using wavelet coefficients based on OMP
    Wu, Shulei
    Chen, Huandong
    Bai, Yong
    Zhao, Zhizhong
    Long, Haixia
    OPTIK, 2015, 126 (15-16): : 1439 - 1444
  • [46] Radiation Dose Reduction for CT Lung Cancer Screening Using Advanced Image Reconstruction Techniques
    Mathieu, K.
    Ai, H.
    Godoy, M.
    Munden, R.
    de Groot, P.
    Chandler, A.
    Pan, T.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [47] Radiation dose reduction during adrenal vein sampling using a new angiographic imaging technology
    Clemens Spink
    Maxim Avanesov
    Alexander Lenz
    Frank Oliver Henes
    Lennart Well
    Thomas Schmidt
    Gerhard Adam
    Harald Ittrich
    Peter Bannas
    Scientific Reports, 12
  • [48] Radiation dose reduction during adrenal vein sampling using a new angiographic imaging technology
    Spink, Clemens
    Avanesov, Maxim
    Lenz, Alexander
    Henes, Frank Oliver
    Well, Lennart
    Schmidt, Thomas
    Adam, Gerhard
    Ittrich, Harald
    Bannas, Peter
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [49] A method to obtain the same levels of CT image noise for patients of various sizes, to minimize radiation dose
    Starck, G
    Lönn, L
    Cederblad, Å
    Forssell-Aronsson, E
    Sjöström, L
    Alpsten, M
    BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (890): : 140 - 150
  • [50] New image-processing and noise-reduction software reduces radiation dose during complex endovascular procedures
    Upchurch, Gilbert, Jr.
    Kirkwood, Melissa L.
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (05) : 1364 - 1365