Evaluating the contamination level of polluted insulators based on the characteristics of leakage current

被引:9
|
作者
Zhao, Shihua [1 ]
Jiang, Xingliang [2 ]
Xie, Yanbin [2 ]
机构
[1] State Grid Hunan Elect Power Corp Res Inst, Changsha 410007, Hunan, Peoples R China
[2] Chongqing Univ, State Key Lab Power Transmiss Equipment & Syst Se, Chongqing 400030, Peoples R China
来源
INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS | 2015年 / 25卷 / 10期
关键词
leakage current; contamination level; relative humidity; temperature; insulators; prediction; support vector machine; CURRENT WAVE-FORMS; FREQUENCY-CHARACTERISTICS; POLYMER INSULATORS; SILICONE-RUBBER; NEURAL-NETWORK; CLASSIFICATION;
D O I
10.1002/etep.1951
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Effective prediction of the contamination level of insulators is an important approach to the prevention of pollution flashover accidents, and the leakage current (LC) is an efficient factor to analyze and detect the contamination level of insulators. In order to predict how severe the contamination level of insulators is and prevent pollution flashover accidents, firstly, some artificial pollution tests have been investigated under different contamination levels, relative humidity (RH), and ambient temperature (T). Secondly, based on the experimental data, the three characteristics of LC, namely the maximum pulse amplitude (I-h), the energy ratio (K), and the energy (E), have been extracted. They reflect jointly the LC from different perspectives. Thirdly, the variation laws between the three characteristics and the contamination level, RH and T, have been obtained. Fourthly, the prediction of the contamination level by using least squares support vector machine (LS-SVM) model has been presented, in which the three characteristics, RH and T are used as the inputs of model, and the contamination level is used as the output of model. Finally, this model has been verified with the test data obtained in the artificial climate chamber, and the prediction results are consistent with the test results. Therefore, the LS-SVM model is acceptable to predict the contamination level of insulators and is of significance for the prevention of pollution flashover accidents. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:2109 / 2123
页数:15
相关论文
共 50 条
  • [21] Extreme value analysis of leakage current envelope of polluted insulators
    Karady, GG
    Amarh, F
    2000 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-4, 2000, : 2531 - 2535
  • [22] Research on flashover performance and leakage current performance of polluted insulators
    Jiang, X. (xljiang@cqu.edu.cn), 1600, Chinese Society for Electrical Engineering (33):
  • [23] EFFECT OF CONTAMINATION ON THE LEAKAGE CURRENT OF INLAND DESERT INSULATORS
    ELSULAIMAN, A
    QURESHI, MI
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1984, 19 (04): : 332 - 339
  • [24] Study on Leakage Current Characteristics and Influence Factors of 110kV Polluted Composite Insulators
    Liu Zhengfa
    Zhou Qing
    Zhang Wuyang
    Li Shimian
    Wu Gaolin
    Hu Jianlin
    Bi Maoqiang
    2018 12TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM 2018), 2018, : 896 - 900
  • [25] Detecting of unnormal conditions of polluted insulators based on analysis phase angle of leakage current
    Palangar, M. Faramarzi
    Mirzaie, M.
    Palangar, Mohammad Faramarzi
    2015 20TH CONFERENCE ON ELECTRICAL POWER DISTRIBUTION NETWORKS CONFERENCE (EPDC), 2015, : 7 - 14
  • [26] Stage pre-warning based on leakage current characteristics before contamination flashover of porcelain and glass insulators
    Li, J. Y.
    Sun, C. X.
    Sima, W. X.
    Yang, Q.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2009, 3 (07) : 605 - 615
  • [27] Measurement of Leakage Current for Monitoring the Performance of Outdoor Insulators in Polluted Environments
    Ramirez, Isaias
    Hernandez, Ramiro
    Montoya, Gerardo
    IEEE ELECTRICAL INSULATION MAGAZINE, 2012, 28 (04) : 29 - 34
  • [28] Factors affecting the leakage current bursts of high voltage polluted insulators
    Gouda, OE
    Amer, GM
    UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings, 2005, : 114 - 117
  • [29] Experimental Study of Leakage Current and Calculation of ESDD of Polluted Composite Insulators
    Joneidi, I. A.
    Shayegani, A. A.
    Mohseni, H.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (05): : 2471 - 2477
  • [30] Evaluating of leakage current of insulators based on the GA-BP neural network
    Zhang Y.
    Wu Y.
    Zhao S.