Disposable circumcision suture device: clinical effect and patient satisfaction

被引:32
|
作者
Lv, Bo-Dong [1 ]
Zhang, Shi-Geng [2 ]
Zhu, Xuan-Wen [1 ]
Zhang, Jie [2 ]
Chen, Gang [2 ]
Chen, Min-Fu [3 ]
Shen, Hong-Liang [4 ]
Pei, Zai-Jun [5 ]
Chen, Zhao-Dian [1 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 1, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Chinese Med Univ, Affiliated Hosp 2, Dept Urol, Hangzhou, Zhejiang, Peoples R China
[3] Peoples Hosp Anji Cty, Dept Urol, Huzhou, Peoples R China
[4] Tradit Chinese Med Hosp Deqing Cty, Dept Urol, Huzhou, Peoples R China
[5] Tradit Chinese Med Hosp Tongxiang Cty, Dept Urol, Jiaxing, Peoples R China
关键词
circumcision; disposable circumcision suture device; patient satisfaction; penis appearance; pre-operative and post-operative pain; Shang ring; PENILE SENSITIVITY; CANCER;
D O I
10.4103/1008-682X.127816
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the benefits of a new disposable circumcision suture device (DCSD). A total of 942 patients were equally divided into three groups (conventional circumcision, Shang ring and disposable suture device group). Patients in the DCSD group were anesthetized with compound 5% lidocaine cream, the others with a 2% lidocaine penile block. Operation time, intra-operative blood loss, incision healing time, intra-operative and post-operative pain, the penile appearance and overall satisfaction degree were measured. Operation time and intra-operative blood loss were significantly lower in the Shang ring and suture device groups compared to the conventional group (P < 0.001). Intra- operative pain was less in the suture device group compared with the other two groups (P < 0.001); whereas post-operative pain was higher in the conventional group compared to the other two groups (P < 0.001). Patients in the suture device (80.57%) and Shang ring (73.57%) groups were more satisfied with penile appearances compared with the conventional circumcision group (20.06%, P < 0.05). Patients in suture device group also healed markedly faster than the conventional group (P < 0.01). The overall satisfaction rate was better in the suture device group (78.66%) compared with the conventional (47.13%) and Shang ring (50.00%) groups (P < 0.05). The combination of DCSD and lidocaine cream resulted in shorter operation and incision healing times, reduced intra- operative and post-operative pain and improved patient satisfaction with the cosmetic appearances.
引用
收藏
页码:453 / 456
页数:4
相关论文
共 50 条
  • [1] Commentary on "Disposable circumcision suture device: clinical effect and patient satisfaction"
    Cao, De-Hong
    Dong, Qiang
    Wei, Qiang
    [J]. ASIAN JOURNAL OF ANDROLOGY, 2015, 17 (03) : 516 - 516
  • [2] A Modified Pressure Dressing to Avoid Severe Bleeding After Circumcision With a Disposable Circumcision Suture Device and a Discussion on the Mechanism of Bleeding With the Disposable Circumcision Suture Device
    Jiang, Wei
    Fu, Jia-Li
    Guo, Wen-Liang
    Yan, Zai-Chun
    Zheng, Ru-Qiang
    Lu, Ji-Ru
    Lai, Xiao-Dong
    [J]. SEXUAL MEDICINE, 2021, 9 (02)
  • [3] MALE CIRCUMCISION WITH A DISPOSABLE CIRCUMCISION SUTURE DEVICE VERSUS CONVENTIONAL CIRCUMCISION: A META-ANALYSIS
    Li, M.
    Ruan, Y.
    Wang, T.
    Wang, S.
    Liu, J.
    [J]. JOURNAL OF SEXUAL MEDICINE, 2017, 14 (01): : S64 - S64
  • [4] Modified Circumcision Using the Disposable Circumcision Suture Device in Children: A Randomized Controlled Trial
    Rao, Jian-Ming
    Huang, He
    Chen, Tao
    Yang, Chun-Gang
    Pan, Ci-Zhong
    Deng, Guang-Cheng
    Shen, Long-Jiang
    Qian, Xiao-Hui
    Peng, Mei-Kang
    Zhou, Hui-Dong
    Peng, Hong-Liang
    [J]. UROLOGY, 2020, 143 : 206 - 211
  • [5] Frenulum Protection Technique in Disposable Circumcision Suture Device for Adult Males
    Lu, Xiaojun
    Piao, Shuguang
    Qin, Shengfei
    Zhang, Kaixuan
    Li, Jiacheng
    Zhou, Wenhao
    Tang, Lei
    Yan, Shi
    Chen, Yuangui
    Yin, Guonan
    Zhou, Tie
    [J]. UROLOGY JOURNAL, 2023, 20 (06) : 424 - 428
  • [6] A Modified Disposable Circumcision Suture Device with Application of Plastic Sheet to Avoid Severe Bleeding After Circumcision
    Li, Miao
    Ang, Xiaojie
    Chen, Weiguo
    Gai, Nianxin
    Xu, Jiangnan
    You, Jiawei
    Huang, Yuhua
    Hou, Jianquan
    [J]. UROLOGY JOURNAL, 2022, 19 (02) : 152 - 156
  • [7] Use of a disposable circumcision suture device versus conventional circumcision: a systematic review and meta-analysis
    Huo, Zhong-Chao
    Liu, Gang
    Li, Xiao-Yan
    Liu, Fei
    Fan, Wen-Ju
    Guan, Ru-Hua
    Li, Pei-Feng
    Mo, De-Yang
    He, Yong-Zhi
    [J]. ASIAN JOURNAL OF ANDROLOGY, 2017, 19 (03) : 362 - 367
  • [8] HOW TO REDUCE INTRACTABLE PREPUCE EDEMA AND FRENULUM SHORTAGE FOLLOWING CIRCUMCISION WITH A DISPOSABLE CIRCUMCISION SUTURE DEVICE?
    Lu, Chin-Heng
    Hsu, Chao-Yu
    Ou, Yen-Chuan
    Tung, Min-Che
    [J]. JOURNAL OF UROLOGY, 2024, 211 (05): : E701 - E701
  • [9] USE OF A DISPOSABLE CIRCUMCISION SUTURE DEVICE. STEP-BY-STEP SURGICAL VIDEO
    Fernandez-Pascual, E.
    Balmori, C.
    Fraile, A.
    Martinez-Salamanca, J., I
    [J]. JOURNAL OF SEXUAL MEDICINE, 2020, 17 (06): : S152 - S152
  • [10] Preputial circumcision performed with a new mechanical stapling tool. The "langhe disposable circumcision suture device". Preliminary experiences
    Pozza, Diego
    Pozza, Carlotta
    Mosca, Augusto
    Pozza, Mariangela
    [J]. ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2019, 91 (04) : 261 - 262