A Modified Disposable Circumcision Suture Device with Application of Plastic Sheet to Avoid Severe Bleeding After Circumcision

被引:4
|
作者
Li, Miao [1 ]
Ang, Xiaojie [1 ]
Chen, Weiguo [1 ]
Gai, Nianxin [1 ]
Xu, Jiangnan [1 ]
You, Jiawei [1 ]
Huang, Yuhua [1 ]
Hou, Jianquan [1 ]
机构
[1] Soochow Univ, Affiliated Hosp 1, Dept Urol, 188 Shizi Rd, Suzhou 215006, Jiangsu, Peoples R China
关键词
circumcision; disposable circumcision suture device; excess foreskin; hemorrhage; modified; MEDICAL MALE CIRCUMCISION; EFFICACY; PHIMOSIS; SAFETY; TRIAL;
D O I
10.22037/uj.v18i.6977
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the effectiveness of a modified disposable circumcision suture device (DCSD) with application of plastic sheet to avoid severe bleeding after circumcision and compare the surgical effects and other postoperative complications of two DCSDs. Materials and Methods: A total of 943 excess foreskin patients from January 2018 to January 2020 who underwent circumcision using two different DCSDs were recruited. Preoperative characteristics (patient age, height and weight), main surgical outcomes (surgical time, intraoperative blood loss, incision healing time) and postoperative complications (postoperative hemorrhage and hematoma rate, edema rate, incision infection rate, residual staples rate) were collected and analyzed. Patients' "satisfaction" or "dissatisfaction" was also investigated. Results: Preoperative characteristics showed no significant statistical difference. The modified DCSD group has a lower intraoperative bleeding, postoperative hemorrhage or hematoma rate and residual staples rate compared with the conventional group. Incision healing time and incision infection rate between the two groups were similar. Nevertheless, conventional group has a shorter surgical time, a lower edema rate and a higher satisfaction rate. Conclusion: The modified DCSD with application of plastic sheet can avoid severe bleeding after circumcision effectively and can be served as a new choice for circumcision.
引用
收藏
页码:152 / 156
页数:5
相关论文
共 17 条
  • [1] A Modified Pressure Dressing to Avoid Severe Bleeding After Circumcision With a Disposable Circumcision Suture Device and a Discussion on the Mechanism of Bleeding With the Disposable Circumcision Suture Device
    Jiang, Wei
    Fu, Jia-Li
    Guo, Wen-Liang
    Yan, Zai-Chun
    Zheng, Ru-Qiang
    Lu, Ji-Ru
    Lai, Xiao-Dong
    [J]. SEXUAL MEDICINE, 2021, 9 (02)
  • [2] Modified Circumcision Using the Disposable Circumcision Suture Device in Children: A Randomized Controlled Trial
    Rao, Jian-Ming
    Huang, He
    Chen, Tao
    Yang, Chun-Gang
    Pan, Ci-Zhong
    Deng, Guang-Cheng
    Shen, Long-Jiang
    Qian, Xiao-Hui
    Peng, Mei-Kang
    Zhou, Hui-Dong
    Peng, Hong-Liang
    [J]. UROLOGY, 2020, 143 : 206 - 211
  • [3] MALE CIRCUMCISION WITH A DISPOSABLE CIRCUMCISION SUTURE DEVICE VERSUS CONVENTIONAL CIRCUMCISION: A META-ANALYSIS
    Li, M.
    Ruan, Y.
    Wang, T.
    Wang, S.
    Liu, J.
    [J]. JOURNAL OF SEXUAL MEDICINE, 2017, 14 (01): : S64 - S64
  • [4] A Huge Anterior Urethral Diverticulum After Circumcision in a Child: An Unusual Complication of Disposable Plastic Circumcision Device
    Balci, Ozlem
    Karaman, Ibrahim
    Karaman, Ayse
    [J]. JOURNAL OF UROLOGICAL SURGERY, 2019, 6 (02): : 165 - 167
  • [5] Disposable circumcision suture device: clinical effect and patient satisfaction
    Lv, Bo-Dong
    Zhang, Shi-Geng
    Zhu, Xuan-Wen
    Zhang, Jie
    Chen, Gang
    Chen, Min-Fu
    Shen, Hong-Liang
    Pei, Zai-Jun
    Chen, Zhao-Dian
    [J]. ASIAN JOURNAL OF ANDROLOGY, 2014, 16 (03) : 453 - 456
  • [6] Use of a disposable circumcision suture device versus conventional circumcision: a systematic review and meta-analysis
    Huo, Zhong-Chao
    Liu, Gang
    Li, Xiao-Yan
    Liu, Fei
    Fan, Wen-Ju
    Guan, Ru-Hua
    Li, Pei-Feng
    Mo, De-Yang
    He, Yong-Zhi
    [J]. ASIAN JOURNAL OF ANDROLOGY, 2017, 19 (03) : 362 - 367
  • [7] HOW TO REDUCE INTRACTABLE PREPUCE EDEMA AND FRENULUM SHORTAGE FOLLOWING CIRCUMCISION WITH A DISPOSABLE CIRCUMCISION SUTURE DEVICE?
    Lu, Chin-Heng
    Hsu, Chao-Yu
    Ou, Yen-Chuan
    Tung, Min-Che
    [J]. JOURNAL OF UROLOGY, 2024, 211 (05): : E701 - E701
  • [8] Commentary on "Disposable circumcision suture device: clinical effect and patient satisfaction"
    Cao, De-Hong
    Dong, Qiang
    Wei, Qiang
    [J]. ASIAN JOURNAL OF ANDROLOGY, 2015, 17 (03) : 516 - 516
  • [9] Frenulum Protection Technique in Disposable Circumcision Suture Device for Adult Males
    Lu, Xiaojun
    Piao, Shuguang
    Qin, Shengfei
    Zhang, Kaixuan
    Li, Jiacheng
    Zhou, Wenhao
    Tang, Lei
    Yan, Shi
    Chen, Yuangui
    Yin, Guonan
    Zhou, Tie
    [J]. UROLOGY JOURNAL, 2023, 20 (06) : 424 - 428
  • [10] Application of a novel disposable suture device in circumcision: a prospective non-randomized controlled study
    Zhang, Zheng
    Yang, Baibing
    Yu, Wen
    Han, Youfeng
    Xu, Zhipeng
    Chen, Hai
    Chen, Yun
    Dai, Yutian
    [J]. INTERNATIONAL UROLOGY AND NEPHROLOGY, 2016, 48 (04) : 465 - 473