Use of a disposable circumcision suture device versus conventional circumcision: a systematic review and meta-analysis

被引:17
|
作者
Huo, Zhong-Chao [1 ,2 ]
Liu, Gang [1 ]
Li, Xiao-Yan [3 ]
Liu, Fei [4 ]
Fan, Wen-Ju [1 ]
Guan, Ru-Hua [5 ]
Li, Pei-Feng [1 ,2 ]
Mo, De-Yang [1 ]
He, Yong-Zhi [1 ]
机构
[1] Peoples Hosp Guangxi Zhuang Autonomous Reg, Dept Urol, Nanning 530021, Guangxi, Peoples R China
[2] Guangxi Univ Tradit Chinese Med, Grad Sch, Nanning 530200, Guangxi, Peoples R China
[3] Peoples Hosp Guangxi Zhuang Autonomous Reg, Dept Operating Room, Nanning 530021, Guangxi, Peoples R China
[4] Peoples Hosp Guangxi Zhuang Autonomous Reg, Res Ctr Med Sci, Nanning 530021, Guangxi, Peoples R China
[5] North China Univ Sci & Technol, Grad Sch, Tangshan 063000, Hebei, Peoples R China
关键词
conventional circumcision; disposable circumcision suture device; meta-analysis; phimosis; redundant prepuce; systematic review; PLASTIC CLAMP TECHNIQUE; HIV-INFECTION; PENILE; RISK; COMPLICATIONS; TRIAL; AFRICA; CANCER; MEN;
D O I
10.4103/1008-682X.174855
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
This systematic review assessed the safety and efficacy of the disposable circumcision suture device (DCSD) and conventional circumcision (CC) in the treatment of redundant prepuce and phimosis. Two independent reviewers conducted a literature search for randomized controlled trials (RCTs) using the DCSD and CC for the treatment of redundant prepuce or phimosis in China and abroad. Nine RCTs (1898 cases) were included. Compared with the CC group, the DCSD group had a shorter operative time (standardized mean difference [SMD] = -21.44; 95% confidence intervals [95% CIs] [-25.08, -17.79]; P < 0.00001), shorter wound healing time (SMD = -3.66; 95% Cl [-5.46, -1.85]; P < 0.0001), less intraoperative blood loss (SMD = -9.64; 95% CI [-11.37, -7.90]; P < 0.00001), better cosmetic penile appearance (odds ratio [OR] = 8.77; 95% Cl [5.90, 13.02]; P < 0.00001), lower intraoperative pain score, lower 24-h postoperative pain score, lower incidence of infection, less incision edema, and fewer adverse events. There were no differences between the CC and DCSD groups in the incidences of dehiscence, or hematoma. The results of this meta-analysis indicate that the DCSD appears to be safer and more effective than CC. However, additional high-quality RCTs with larger study populations are needed.
引用
收藏
页码:362 / 367
页数:6
相关论文
共 50 条
  • [1] MALE CIRCUMCISION WITH A DISPOSABLE CIRCUMCISION SUTURE DEVICE VERSUS CONVENTIONAL CIRCUMCISION: A META-ANALYSIS
    Li, M.
    Ruan, Y.
    Wang, T.
    Wang, S.
    Liu, J.
    [J]. JOURNAL OF SEXUAL MEDICINE, 2017, 14 (01): : S64 - S64
  • [2] Disposable circumcision suture devices versus Shang ring circumcision for management of redundant prepuce or phimosis: A systematic review and meta-analysis
    Huang, ChuiGuo
    Song, Pan
    Zhou, SiRan
    Dai, Yu
    Xu, ChangBao
    Gao, Yuan
    Zhao, XingHua
    [J]. REVISTA INTERNACIONAL DE ANDROLOGIA, 2017, 15 (03): : 108 - 118
  • [3] A Systematic Review and Meta-analysis of Circumcision With Shang Ring vs Conventional Circumcision
    Cao, Dehong
    Liu, Liangren
    Hu, Yingchun
    Wang, Jia
    Yuan, Jiuhong
    Dong, Qiang
    Wei, Qiang
    [J]. UROLOGY, 2015, 85 (04) : 799 - 804
  • [4] A Modified Pressure Dressing to Avoid Severe Bleeding After Circumcision With a Disposable Circumcision Suture Device and a Discussion on the Mechanism of Bleeding With the Disposable Circumcision Suture Device
    Jiang, Wei
    Fu, Jia-Li
    Guo, Wen-Liang
    Yan, Zai-Chun
    Zheng, Ru-Qiang
    Lu, Ji-Ru
    Lai, Xiao-Dong
    [J]. SEXUAL MEDICINE, 2021, 9 (02)
  • [5] Plastic Clamp Versus Conventional Surgical Dissection Technique in Pediatric Circumcision: A Systematic Review and Meta-Analysis
    Yao, Xianming
    Zhang, Gang
    Xiong, Qianwei
    Feng, Shaoguang
    Liu, Xian
    [J]. CURRENT UROLOGY REPORTS, 2024, 25 (08) : 173 - 180
  • [6] The Use of Tissue Glue for Circumcision in Children: Systematic Review and Meta-analysis
    Martin, Amy
    Nataraja, Ramesh M.
    Kimber, Chris
    Pacilli, Maurizio
    [J]. UROLOGY, 2018, 115 : 21 - 28
  • [7] Modified Circumcision Using the Disposable Circumcision Suture Device in Children: A Randomized Controlled Trial
    Rao, Jian-Ming
    Huang, He
    Chen, Tao
    Yang, Chun-Gang
    Pan, Ci-Zhong
    Deng, Guang-Cheng
    Shen, Long-Jiang
    Qian, Xiao-Hui
    Peng, Mei-Kang
    Zhou, Hui-Dong
    Peng, Hong-Liang
    [J]. UROLOGY, 2020, 143 : 206 - 211
  • [8] Disposable circumcision suture device: clinical effect and patient satisfaction
    Lv, Bo-Dong
    Zhang, Shi-Geng
    Zhu, Xuan-Wen
    Zhang, Jie
    Chen, Gang
    Chen, Min-Fu
    Shen, Hong-Liang
    Pei, Zai-Jun
    Chen, Zhao-Dian
    [J]. ASIAN JOURNAL OF ANDROLOGY, 2014, 16 (03) : 453 - 456
  • [9] A Randomized Clinical Study of Circumcision with a Ring Device Versus Conventional Circumcision
    Yuea, Cheng
    Yan Ze-juna
    Wu, Ke-rong
    Sua, Xin-jun
    Hua, Jia-sheng
    Maa, Jian-wei
    Guoa, Chuan-min
    Fanga, Hai-wei
    Sua, Rui
    Zhang, Yao
    Zhangc, Qing-hua
    [J]. JOURNAL OF UROLOGY, 2012, 188 (06): : 2443 - 2443
  • [10] Male circumcision and penile cancer: a systematic review and meta-analysis
    Natasha L. Larke
    Sara L. Thomas
    Isabel dos Santos Silva
    Helen A. Weiss
    [J]. Cancer Causes & Control, 2011, 22 : 1097 - 1110