Disposable circumcision suture device: clinical effect and patient satisfaction

被引:32
|
作者
Lv, Bo-Dong [1 ]
Zhang, Shi-Geng [2 ]
Zhu, Xuan-Wen [1 ]
Zhang, Jie [2 ]
Chen, Gang [2 ]
Chen, Min-Fu [3 ]
Shen, Hong-Liang [4 ]
Pei, Zai-Jun [5 ]
Chen, Zhao-Dian [1 ]
机构
[1] Zhejiang Univ, Affiliated Hosp 1, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Chinese Med Univ, Affiliated Hosp 2, Dept Urol, Hangzhou, Zhejiang, Peoples R China
[3] Peoples Hosp Anji Cty, Dept Urol, Huzhou, Peoples R China
[4] Tradit Chinese Med Hosp Deqing Cty, Dept Urol, Huzhou, Peoples R China
[5] Tradit Chinese Med Hosp Tongxiang Cty, Dept Urol, Jiaxing, Peoples R China
关键词
circumcision; disposable circumcision suture device; patient satisfaction; penis appearance; pre-operative and post-operative pain; Shang ring; PENILE SENSITIVITY; CANCER;
D O I
10.4103/1008-682X.127816
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the benefits of a new disposable circumcision suture device (DCSD). A total of 942 patients were equally divided into three groups (conventional circumcision, Shang ring and disposable suture device group). Patients in the DCSD group were anesthetized with compound 5% lidocaine cream, the others with a 2% lidocaine penile block. Operation time, intra-operative blood loss, incision healing time, intra-operative and post-operative pain, the penile appearance and overall satisfaction degree were measured. Operation time and intra-operative blood loss were significantly lower in the Shang ring and suture device groups compared to the conventional group (P < 0.001). Intra- operative pain was less in the suture device group compared with the other two groups (P < 0.001); whereas post-operative pain was higher in the conventional group compared to the other two groups (P < 0.001). Patients in the suture device (80.57%) and Shang ring (73.57%) groups were more satisfied with penile appearances compared with the conventional circumcision group (20.06%, P < 0.05). Patients in suture device group also healed markedly faster than the conventional group (P < 0.01). The overall satisfaction rate was better in the suture device group (78.66%) compared with the conventional (47.13%) and Shang ring (50.00%) groups (P < 0.05). The combination of DCSD and lidocaine cream resulted in shorter operation and incision healing times, reduced intra- operative and post-operative pain and improved patient satisfaction with the cosmetic appearances.
引用
收藏
页码:453 / 456
页数:4
相关论文
共 50 条
  • [41] The effect of clinical teaching on patient satisfaction in rural and community settings
    Law, Madelyn
    Hamilton, Maren
    Bridge, Erica
    Brown, Allison
    Greenway, Matthew
    [J]. CANADIAN JOURNAL OF RURAL MEDICINE, 2014, 19 (02) : 57 - 62
  • [42] The effect of male circumcision on pudendal evoked potentials and sexual satisfaction
    Senol, Mehmet Gueney
    Sen, Buelent
    Karademir, Kenan
    Sen, Hueseyin
    Saracoglu, Mehmet
    [J]. ACTA NEUROLOGICA BELGICA, 2008, 108 (03) : 90 - 93
  • [43] Patient satisfaction with radiofrequency tissue tightening device
    Rostan, E
    [J]. LASERS IN SURGERY AND MEDICINE, 2004, : 71 - 71
  • [44] Editorial Comment from Dr Senel to Circumcision with a novel disposable device in Chinese children: A randomized controlled trial
    Senel, Ferda M.
    [J]. INTERNATIONAL JOURNAL OF UROLOGY, 2013, 20 (02) : 227 - 228
  • [45] Editorial Comment from Dr Mohta to Circumcision with a novel disposable device in Chinese children: A randomized controlled trial
    Mohta, Anup
    [J]. INTERNATIONAL JOURNAL OF UROLOGY, 2013, 20 (02) : 228 - 229
  • [46] Effect of Various Vital Bleaching Systems on Clinical Outcomes and Patient Satisfaction
    Elnawawy, Mohamed Samir A.
    Gharote, Harshkant
    Pullishery, Fawaz
    Al Wakeb, Rehab
    Abuzenada, Basem
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [47] Does circumcision has an effect on female's perception of sexual satisfaction?
    Cortes-Gonzalez, Jeff R.
    Arratia-Maqueo, Jorge A.
    Gomez-Guerra, Lauro S.
    [J]. REVISTA DE INVESTIGACION CLINICA-CLINICAL AND TRANSLATIONAL INVESTIGATION, 2008, 60 (03): : 227 - 230
  • [48] Is It the Surgeon, the Patient, or the Device? A Comprehensive Clinical and Radiological Evaluation of Factors Influencing Patient Satisfaction in 648 Total Knee Arthroplasties
    Rissolio, Lorenzo
    Sabatini, Luigi
    Risitano, Salvatore
    Bistolfi, Alessandro
    Galluzzo, Umberto
    Masse, Alessandro
    Indelli, Pier Francesco
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (12)
  • [49] PREFERMS study: fingolimod switch effect on patient retention, key clinical outcomes and patient satisfaction
    Hunter, S. F.
    Cascione, M.
    Thomas, F. P.
    Cree, B. A. C.
    Meng, X.
    Schofield, L.
    Tenenbaum, N.
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2016, 22 : 782 - 782
  • [50] A prospective cohort study of safety and patient satisfaction of voluntary medical male circumcision in Botswana
    Wirth, Kathleen E.
    Semo, Bazghina-werq
    Spees, Lisa P.
    Ntsuape, Conrad
    Barnhart, Scott
    Ledikwe, Jenny H.
    [J]. PLOS ONE, 2017, 12 (11):