Model validation and case study on internally cooled/heated dehumidifier/regenerator of liquid desiccant systems

被引:75
|
作者
Yin, Yonggao [1 ]
Zhang, Xiaosong [1 ]
Peng, Donggen [1 ]
Li, Xiuwei [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid desiccant; Internally heated regenerator; Internally cooled dehumidifier; Optimal design; MASS-TRANSFER; HEAT; AIR; PERFORMANCE; FILM; REGENERATOR; ABSORPTION;
D O I
10.1016/j.ijthermalsci.2008.12.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
Traditional dehumidifiers and regenerators of liquid desiccant systems often use packed columns supporting adiabatic heat and mass transfer between air and liquid desiccant. As new-style equipment, internally-cooled dehumidifiers can improve dehumidification performance due to restraining temperature increase of the desiccant. Similar to internally-cooled dehumidifiers, an idea of internally heating is imitated to put forward internally-heated regenerators. The uniform mathematical model for an internally cooled dehumidifier and internally heated regenerator was presented and validated by comparison of computation results with experimental data in this study. The case study focused on the parameters distribution comparisons of the internally cooled/heated dehumidifier/regenerator with adiabatic ones and demonstrated coupled heat and mass transfer behavior. The results show that the internally-heated regenerator can produce higher regeneration efficiency than the adiabatic one to produce better energy efficiency and eliminate the dehumidification possibility which would happen in adiabatic regenerators. The internally-cooled dehumidifier can also provide better dehumidification performance comparing with the adiabatic one; however its benefit would be not as good as the internally-heated regenerator. In addition, effect of the width of the air channel on internally cooled/heated dehumidifier/regenerator was discussed and the results can help the optimal design of this kind of dehumidifiers and regenerators. (C) 2008 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1664 / 1671
页数:8
相关论文
共 50 条
  • [41] Experimental analysis of mass transfer in adiabatic structured packing dehumidifier/regenerator with liquid desiccant
    Zhang, Li
    Hihara, Eiji
    Matsuoka, Fumio
    Dang, Chaobin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2010, 53 (13-14) : 2856 - 2863
  • [42] Review of internally cooled liquid desiccant air dehumidification: Materials, components, systems, and performances
    Guan, Bowen
    Zhang, Tao
    Liu, Jun
    Liu, Xiaohua
    Yin, Yonggao
    BUILDING AND ENVIRONMENT, 2022, 211
  • [43] High-performance multi-stage internally-cooled liquid desiccant dehumidifier for high gas-liquid flow ratios
    Fang, Song
    Xu, Zhuoren
    Zhang, Hanwei
    Rong, Yangyiming
    Zhou, Xia
    Zhi, Xiaoqin
    Wang, Kai
    Markides, Christos N.
    Qiu, Limin
    ENERGY CONVERSION AND MANAGEMENT, 2021, 250
  • [44] Three dimensional model and parametric analysis of internally-cooled liquid desiccant absorber
    Wu, AnMin
    Zhang, Hefei
    IMECS 2007: INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS, VOLS I AND II, 2007, : 2139 - +
  • [45] Study on the influence characteristics of thermal effect of internally cooled dehumidifier
    Du, Boyao
    Zhang, Guangkai
    Xie, Jingchao
    Liu, Honggang
    Liu, Jiaping
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [46] Experimental study on partially internally cooled dehumidification in liquid desiccant air conditioning system
    Gao, W. Z.
    Shi, Y. R.
    Cheng, Y. P.
    Sun, W. Z.
    ENERGY AND BUILDINGS, 2013, 61 : 202 - 209
  • [47] Performance study of the internally-cooled ultrasonic atomization liquid desiccant dehumidification system
    Yang, Zili
    Tao, Ruiyang
    Ni, Hui
    Zhong, Ke
    Lian, Zhiwei
    ENERGY, 2019, 175 : 745 - 757
  • [48] Comparative study on internally heated and adiabatic regenerators in liquid desiccant air conditioning system
    Yin, Yonggao
    Zhang, Xiaosong
    BUILDING AND ENVIRONMENT, 2010, 45 (08) : 1799 - 1807
  • [49] Experimental and theoretical analysis of heat and mass transfer in a packed column dehumidifier/regenerator with liquid desiccant
    Longo, GA
    Gasparella, A
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (25-26) : 5240 - 5254
  • [50] Analytical solutions of coupled heat and mass transfer processes in liquid desiccant air dehumidifier/regenerator
    Liu, Xiaohua
    Jiang, Yi
    Xia, Jianjun
    Chang, Xiaomin
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (07) : 2221 - 2232