Model validation and case study on internally cooled/heated dehumidifier/regenerator of liquid desiccant systems

被引:75
|
作者
Yin, Yonggao [1 ]
Zhang, Xiaosong [1 ]
Peng, Donggen [1 ]
Li, Xiuwei [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
基金
中国国家自然科学基金;
关键词
Liquid desiccant; Internally heated regenerator; Internally cooled dehumidifier; Optimal design; MASS-TRANSFER; HEAT; AIR; PERFORMANCE; FILM; REGENERATOR; ABSORPTION;
D O I
10.1016/j.ijthermalsci.2008.12.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
Traditional dehumidifiers and regenerators of liquid desiccant systems often use packed columns supporting adiabatic heat and mass transfer between air and liquid desiccant. As new-style equipment, internally-cooled dehumidifiers can improve dehumidification performance due to restraining temperature increase of the desiccant. Similar to internally-cooled dehumidifiers, an idea of internally heating is imitated to put forward internally-heated regenerators. The uniform mathematical model for an internally cooled dehumidifier and internally heated regenerator was presented and validated by comparison of computation results with experimental data in this study. The case study focused on the parameters distribution comparisons of the internally cooled/heated dehumidifier/regenerator with adiabatic ones and demonstrated coupled heat and mass transfer behavior. The results show that the internally-heated regenerator can produce higher regeneration efficiency than the adiabatic one to produce better energy efficiency and eliminate the dehumidification possibility which would happen in adiabatic regenerators. The internally-cooled dehumidifier can also provide better dehumidification performance comparing with the adiabatic one; however its benefit would be not as good as the internally-heated regenerator. In addition, effect of the width of the air channel on internally cooled/heated dehumidifier/regenerator was discussed and the results can help the optimal design of this kind of dehumidifiers and regenerators. (C) 2008 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1664 / 1671
页数:8
相关论文
共 50 条
  • [21] Quick performance prediction for internally cooled/heated liquid desiccant dehumidification system
    Qi, Ronghui
    Lu, Lin
    Yang, Hongxing
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2014, 35 (01): : 99 - 112
  • [22] Experimental study on dehumidifier and regenerator of liquid desiccant cooling air conditioning system
    Yin, Yonggao
    Zhang, Xiaosong
    Chen, Zhenqian
    BUILDING AND ENVIRONMENT, 2007, 42 (07) : 2505 - 2511
  • [23] Study on performance of dehumidifier and regenerator of liquid desiccant cooling air conditioning system
    Yin, YG
    Zhang, XS
    Li, YL
    Wu, W
    Chen, ZQ
    Guan, ZS
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1274 - 1278
  • [24] Research on the field uniformity principle in liquid desiccant dehumidifier/regenerator
    Liu, Xiaohua
    Yi, Xiaoqin
    Chang, Xiaomin
    Jiang, Yi
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2009, 30 (07): : 939 - 945
  • [25] Experimental studies on the dehumidifier and regenerator of a liquid desiccant cooling system
    Jain, S
    Dhar, PL
    Kaushik, SC
    APPLIED THERMAL ENGINEERING, 2000, 20 (03) : 253 - 267
  • [26] Heat and mass transfer model of cross flow liquid desiccant air dehumidifier/regenerator
    Liu, X. H.
    Jiang, Y.
    Qu, K. Y.
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (02) : 546 - 554
  • [27] Experimental analysis of dehumidification performance of an evaporative cooling-assisted internally cooled liquid desiccant dehumidifier
    Park, Joon-Young
    Kim, Beom-Jun
    Yoon, Soo-Yeol
    Byon, Yoo-Suk
    Jeong, Jae-Weon
    APPLIED ENERGY, 2019, 235 : 177 - 185
  • [28] Experimental and theoretical research of a fin-tube type internally-cooled liquid desiccant dehumidifier
    Luo, Yimo
    Shao, Shuangquan
    Xu, Hongbo
    Tian, Chongqing
    Yang, Hongxing
    APPLIED ENERGY, 2014, 133 : 127 - 134
  • [29] Energy consumption and optimization of internally cooled/heated liquid desiccant air-conditioning system: A case study in Hong Kong
    Qi, Ronghui
    Lu, Lin
    ENERGY, 2014, 73 : 801 - 808
  • [30] Heat and mass transfer in an adjacent internally-cooled membrane-based liquid desiccant dehumidifier (AIMLDD)
    Yang, Yu
    Yang, Minlin
    Huang, Weihao
    Huang, Si-Min
    Ye, Wei-Biao
    Hong, Yuxiang
    Qin, Frank G. F.
    Shao, Youyuan
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 3990 - 3997