Experimental study on partially internally cooled dehumidification in liquid desiccant air conditioning system

被引:49
|
作者
Gao, W. Z. [1 ]
Shi, Y. R. [1 ]
Cheng, Y. P. [2 ]
Sun, W. Z. [1 ]
机构
[1] Shanghai Maritime Univ, Dept Marine, Shanghai 201306, Peoples R China
[2] Natl Univ Singapore, Dept Chem & Biomol Engn, Singapore 117576, Singapore
基金
中国国家自然科学基金;
关键词
Adiabatic; Partially internally cooled; Dehumidifier; Sherwood number Sh; MASS-TRANSFER PROCESSES; HEAT; DEHUMIDIFIER/REGENERATOR; PERFORMANCE;
D O I
10.1016/j.enbuild.2013.02.034
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The dehumidifier is one of the essential components in air-conditioning systems with liquid desiccant. Compared with adiabatic dehumidifiers, internally cooled dehumidifiers can achieve better dehumidification performance. In this study, dehumidification effectiveness and moisture removal rate were adopted to evaluate and compare the performance of these two kinds of dehumidifiers. The results indicated that internally cooled dehumidifiers can significantly improve performance compared with adiabatic dehumidifiers, especially when the solution is at a high temperature and/or low concentration in the downstream section of the liquid desiccant flow. Performance improvement and energy saving can be taken into consideration simultaneously by only supplying cooling water to the latter part of the dehumidifier. Solution temperatures at 20-25 degrees C for adiabatic dehumidifiers are optimal and those at 25-30 degrees C for internal cooled types. Lower temperatures of the cooling water can result in higher values for dehumidification effectiveness and moisture removal rate in an internally cooled dehumidifier; the limited temperature difference between cooling water and solution might seriously weaken the effect of the cooling water. Dimensionless Sherwood number Sh was calculated, and discrepancies between predicted values and experimental data are almost within +/- 20%. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:202 / 209
页数:8
相关论文
共 50 条
  • [1] Transient performance study of an internally-cooled plate membrane liquid desiccant air dehumidification system
    Yang, Yu
    Yan, Junwei
    Zhou, Xuan
    Xiao, Liehui
    Huang, Si-Min
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 87 - 100
  • [2] Experimental study on a hybrid desiccant dehumidification and air conditioning system
    Yong, L
    Sumathy, K
    Dai, YJ
    Zhong, JH
    Wang, RZ
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (01): : 77 - 82
  • [3] Performance study of the internally-cooled ultrasonic atomization liquid desiccant dehumidification system
    Yang, Zili
    Tao, Ruiyang
    Ni, Hui
    Zhong, Ke
    Lian, Zhiwei
    [J]. ENERGY, 2019, 175 : 745 - 757
  • [4] Performance characteristics of a novel internally-cooled plate membrane liquid desiccant air dehumidification system
    Xiao, Liehui
    Yang, Minlin
    Yuan, Wu-Zhi
    Huang, Si-Min
    [J]. APPLIED THERMAL ENGINEERING, 2020, 172
  • [5] Quick performance prediction for internally cooled/heated liquid desiccant dehumidification system
    Qi, Ronghui
    Lu, Lin
    Yang, Hongxing
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2014, 35 (01): : 99 - 112
  • [6] Performance of heat pump driven internally cooled liquid desiccant dehumidification system
    Liu, Jun
    Liu, Xiaohua
    Zhang, Tao
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 205
  • [7] Comparison of internally cooled and adiabatic liquid desiccant dehumidification-regeneration system
    Liu, Jun
    Liu, Xiaohua
    Zhang, Tao
    [J]. BUILDING AND ENVIRONMENT, 2019, 163
  • [8] Review of internally cooled liquid desiccant air dehumidification: Materials, components, systems, and performances
    Guan, Bowen
    Zhang, Tao
    Liu, Jun
    Liu, Xiaohua
    Yin, Yonggao
    [J]. BUILDING AND ENVIRONMENT, 2022, 211
  • [9] Response surface modeling and optimization scheme of an internally cooled liquid desiccant air conditioning system
    Zhang, Yanling
    Zhang, Hao
    Yang, Hongxing
    Chen, Yi
    Leung, Chun Wah
    [J]. JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [10] EXPERIMENTAL ANALYSIS OF AIR DEHUMIDIFICATION SYSTEM WITH LIQUID DESICCANT
    Zhang, Li
    Chitose, Tanaka
    Hihara, Eiji
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 8, 2010, : 169 - 177