Anti-scatter grid evaluation for wide-cone CT

被引:7
|
作者
Melnyk, Roman [1 ]
Boudry, John [1 ]
Liu, Xin [2 ]
Adamak, Mark [1 ]
机构
[1] GE Healthcare, Waukesha, WI 53188 USA
[2] Missouri Univ Sci Technol, Rolla, MO 65409 USA
关键词
anti-scatter grid; scatter rejection; wide-cone CT;
D O I
10.1117/12.2043619
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Scatter is a significant source of image artifacts in wide-cone CT. Scatter management includes both scatter rejection and scatter correction. The common scatter rejection approach is to use an anti-scatter grid (ASG). Conventional CT scanners (with detector coverage not exceeding 40mm along the patient axis) typically employ one-dimensional (1D) ASGs. Such grids are quite effective for small cone angles. For larger cone angles, however, simply increasing the aspect ratio of a 1D ASG is not sufficient. In addition, a 1D ASG offers no scatter rejection along the patient axis. To ensure adequate image quality in wide-cone CT, a two-dimensional (2D) ASG is needed. In this work, we measured the amount of scatter and the degree of image artifacts typically attributable to scatter for four prototype 2D ASG designs, and we compared those to a 1D ASG. The scatter was measured in terms of the scatter-to-primary ratio (SPR). The cupping and ghosting artifacts were assessed through quantitative metrics. For the 2D ASGs, when compared to the 1D ASG, the SPR decreased by up to 66% and 75% for 35cm water and 48cm polyethylene, respectively, phantoms, at 80-160mm apertures (referenced to isocenter), as measured by the pinhole method. As measured by the two-aperture method, the SPR reduction was 59%-68% at isocenter for the 35cm water phantom at 160mm aperture. The cupping artifact was decreased by up to similar to 80%. The ghosting artifact was reduced as well. The results of the evaluation clearly demonstrate the advantage of using a 2D ASG for wide-cone CT.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Micromachined hetero-core anti-scatter grid for a digital X-ray image sensor
    Jeong, Dae-Hun
    Lee, Jong-Hyun
    SENSORS AND ACTUATORS A-PHYSICAL, 2012, 185 : 145 - 150
  • [42] A new solution for radiation transmission in anti-scatter grids
    Zhou, Abel
    Yin, Yuming
    White, Graeme L.
    Davidson, Rob
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (05):
  • [43] Anti-scatter grid artifact elimination for high resolution x-ray imaging CMOS detectors
    Rana, R.
    Singh, V.
    Jain, A.
    Bednarek, D. R.
    Rudin, S.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [44] Performance study of the anti-scatter grid for sub-megavolt X- ray flash radiography
    Liu Wen-jie
    Liu Jun
    Xiao Zhiqiang
    APPLIED MECHANICS AND MATERIALS I, PTS 1-3, 2013, 275-277 : 1994 - 1997
  • [45] Radiation dose considerations in digital radiography with an anti-scatter grid: A study using adult and pediatric phantoms
    Kawashima, Hiroki
    Ichikawa, Katsuhiro
    Kitao, Azusa
    Matsubara, Takashi
    Sugiura, Takumi
    Kobayashi, Tomohiro
    Kobayashi, Satoshi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (09):
  • [46] Impact of anti-scatter grid design image quality of CBCT scans for head and neck cancer imaging
    Stankovic, U.
    Van Herk, M.
    Ploeger, L. S.
    Van Kranen, S.
    Sonke, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S265 - S265
  • [47] The determination of the optimal strip-thickness of anti-scatter grids for a given grid ratio and strip height
    Zhou, Abel
    Yin, Yuming
    Tan, Qi
    White, Graeme L.
    Davidson, Rob
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2020, 30 (04) : 916 - 925
  • [48] Performance Evaluation of a Custom-Made Anti-Scatter Grid Used for the High-Resolution Micro-Angiographic Fluoroscope (MAF)
    Jain, A.
    Bednarek, D. R.
    Rudin, S.
    MEDICAL PHYSICS, 2009, 36 (06) : 2765 - +
  • [49] Scatter Correction Method for Cone Beam CT Using Beam Attenuation Grid
    Xie, Shipeng
    Luo, Limin
    Yang, Lifeng
    Zhang, Feng
    MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES, PTS 1 AND 2, 2011, 480-481 : 341 - +
  • [50] An analysis of radiation dose reduction in paediatric interventional cardiology by altering frame rate and use of the anti-scatter grid
    McFadden, S. L.
    Hughes, C. M.
    Mooney, R. B.
    JWinder, Robert
    JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (02) : 433 - 443