Anti-scatter grid evaluation for wide-cone CT

被引:7
|
作者
Melnyk, Roman [1 ]
Boudry, John [1 ]
Liu, Xin [2 ]
Adamak, Mark [1 ]
机构
[1] GE Healthcare, Waukesha, WI 53188 USA
[2] Missouri Univ Sci Technol, Rolla, MO 65409 USA
关键词
anti-scatter grid; scatter rejection; wide-cone CT;
D O I
10.1117/12.2043619
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Scatter is a significant source of image artifacts in wide-cone CT. Scatter management includes both scatter rejection and scatter correction. The common scatter rejection approach is to use an anti-scatter grid (ASG). Conventional CT scanners (with detector coverage not exceeding 40mm along the patient axis) typically employ one-dimensional (1D) ASGs. Such grids are quite effective for small cone angles. For larger cone angles, however, simply increasing the aspect ratio of a 1D ASG is not sufficient. In addition, a 1D ASG offers no scatter rejection along the patient axis. To ensure adequate image quality in wide-cone CT, a two-dimensional (2D) ASG is needed. In this work, we measured the amount of scatter and the degree of image artifacts typically attributable to scatter for four prototype 2D ASG designs, and we compared those to a 1D ASG. The scatter was measured in terms of the scatter-to-primary ratio (SPR). The cupping and ghosting artifacts were assessed through quantitative metrics. For the 2D ASGs, when compared to the 1D ASG, the SPR decreased by up to 66% and 75% for 35cm water and 48cm polyethylene, respectively, phantoms, at 80-160mm apertures (referenced to isocenter), as measured by the pinhole method. As measured by the two-aperture method, the SPR reduction was 59%-68% at isocenter for the 35cm water phantom at 160mm aperture. The cupping artifact was decreased by up to similar to 80%. The ghosting artifact was reduced as well. The results of the evaluation clearly demonstrate the advantage of using a 2D ASG for wide-cone CT.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Scatter dose calculation for anti-scatter linear grids in mammography
    Al Kafi, M. A.
    Maalej, N.
    Naqvi, A. A.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (10) : 1837 - 1841
  • [32] Perturbation-Based Quality Surrogate for Scatter Estimation and Parameter Optimization in Anti-Scatter Grid (ASG)-CBCT
    Ruan, D.
    Bayat, F.
    Altunbas, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E174 - E175
  • [33] Focused anti-scatter grid for background reduction in x-ray fluorescence tomography
    Larsson, Jakob C.
    Shaker, Kian
    Hertz, Hans M.
    OPTICS LETTERS, 2018, 43 (11) : 2591 - 2594
  • [34] Investigation of 2D anti-scatter grid implementation in a gantry-mounted cone beam computed tomography system for proton therapy
    Pyakurel, Uttam
    Zhang, Yawei
    Sabounchi, Ryan
    Bayat, Farhang
    Brousmiche, Sebastien
    Bryant, Curtis
    Mendenhall, Nancy
    Johnson, Perry
    Altunbas, Cem
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2025, 33
  • [35] Quantifying Patient Thickness for Which An Anti-Scatter Grid Is Unnecessary for Digital Radiographic Abdomen Exams
    Fritz, S.
    Jones, A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3895 - 3895
  • [36] Anti-Scatter Grid Performance in 2D Breast X-Ray Imaging
    Boggs, R.
    Yester, M.
    Barnes, G.
    MEDICAL PHYSICS, 2020, 47 (06) : E514 - E514
  • [37] Optimized anti-scatter grids for flat panel detectors
    Lendl, Markus
    Medical Imaging 2007: Physics of Medical Imaging, Pts 1-3, 2007, 6510 : U1236 - U1246
  • [38] Development of oriented metallic patterns using LIGA process for focused anti-scatter grid application
    Kim, Kanghyun
    Park, Kyungjin
    Lim, Geunbae
    Kim, Jong Hyun
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2019, 58 (SD)
  • [39] PERFORMANCE-CHARACTERISTICS OF IMPROVED ANTI-SCATTER GRIDS
    SORENSON, JA
    NIKLASON, LT
    KNUTTI, DF
    MEDICAL PHYSICS, 1980, 7 (05) : 525 - 528
  • [40] MEASUREMENT OF THE PERFORMANCE-CHARACTERISTICS OF ANTI-SCATTER GRIDS
    KEEVIL, SF
    LAWINSKI, CP
    MORTON, EJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (03): : 397 - 401