Scatter Correction Method for Cone Beam CT Using Beam Attenuation Grid

被引:1
|
作者
Xie, Shipeng [1 ]
Luo, Limin [1 ]
Yang, Lifeng
Zhang, Feng [1 ]
机构
[1] Southeast Univ, Sch Comp Sci & Engn, Nanjing, Jiangsu, Peoples R China
关键词
scatter correction; Compton scatters; cone-beam computed tomography; CORRECTION ALGORITHM; MODEL; RADIOGRAPHY;
D O I
10.4028/www.scientific.net/KEM.480-481.341
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The scattering phenomenon has an important influence on the reconstructed image in Cone Beam CT (CBCT) imaging systems, and is a long-lasting research topic on CBCT. Focusing on the scatter artifact in the cone beam CT system, we proposed a new scatter correction method that needed to add a beam attenuation grid (BAG) between the X - ray source and the tested object. This study educed the scatter correction algorithm based on the Beer theorem. Through subtracting the scatter distribution image from the original projection image, we can acquire the scatter-corrected projection Images of the tested object. The method has been verified by preliminary experimental results on phantom. The result showed that the method can effectively reduce the scatter artifacts, increase the image contrast and increase the quality of the reconstructed slice image. This method is computationally efficient and easy to implement without the loss of real-time imaging capabilities.
引用
收藏
页码:341 / +
页数:3
相关论文
共 50 条
  • [1] A PRACTICAL METHOD FOR SCATTER CORRECTION IN CONE BEAM CT
    Ploeger, L.
    Sonke, J. J.
    van Herk, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S129 - S129
  • [2] A rotating beam-blocker method for cone beam CT scatter correction
    Cui, Hehe
    Zhan, Haolin
    Yuan, Xiaogang
    Yang, Yidong
    [J]. MEDICAL PHYSICS, 2024, : 7320 - 7331
  • [3] A Hybrid Scatter Correction Method for Cone-Beam CT
    Zhang, Feng
    Yan, Bin
    Li, Jianxin
    Li, Lei
    Jia, Pengxiang
    Hu, Guoen
    [J]. 2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 23 - 27
  • [4] A new scatter correction method for KV and MV cone beam CT
    Li, X.
    Li, T.
    Yang, Y.
    Heron, D.
    Huq, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S643 - S644
  • [5] A Practical and Robust Method for Beam-Blocker Based Cone Beam CT Scatter Correction
    Cui, H.
    Jiang, X.
    Yang, Y.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : E122 - E123
  • [6] A practical and robust method for beam blocker-based cone beam CT scatter correction
    Cui, Hehe
    Jiang, Xiao
    Tang, Wei
    Lu, Hsiao-Ming
    Yang, Yidong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (04):
  • [7] Correction of scatter in megavoltage cone-beam CT
    Spies, L
    Ebert, M
    Groh, BA
    Hesse, BM
    Bortfeld, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03): : 821 - 833
  • [8] An Image-Domain Based Cone Beam CT Scatter Correction Method
    Li, X.
    Li, T.
    Yang, Y.
    Heron, D.
    Huq, M.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [9] Scatter Correction for Cone Beam CT Using Half-Beam Blocker and Local-Filtration Scatter Estimation
    Cui, H.
    Jiang, X.
    Yang, Y.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [10] Scatter Correction for Cone-Beam CT in Radiation Therapy
    Zhu, L.
    Xing, L.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)