Influence of cataract on optical coherence tomography image quality and retinal thickness

被引:99
|
作者
van Velthoven, M. E. J.
van der Linden, M. H.
de Smet, M. D.
Faber, D. J.
Verbraak, F. D.
机构
[1] Acad Med Ctr, Dept Ophthalmol, NL-1105 AZ Amsterdam, Netherlands
[2] OMC Haarlem, Haarlem, Netherlands
关键词
D O I
10.1136/bjo.2004.097022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: As optical coherence tomography ( OCT) is widely used for diagnosis and monitoring of ocular pathology, especially in the elderly people, the influence of cataract on image quality and macular retinal thickness was studied. Methods: In 29 patients scheduled for cataract surgery, preoperative and postoperative OCT scans were obtained. Cataracts were categorised as nuclear, posterior or cortical. Parameters for image quality ( signal-to-noise ratio ( SNR)) and signal strength and macular thickness were compared. A three-level expert grading scale was used to evaluate the discriminative abilities of SNR and signal strength. Results: Nuclear cataracts ( n = 12) provided better preoperative scans ( higher SNR/ signal strength) than posterior ( n = 7) and cortical ( n = 10) cataracts ( p < 0.004). Postoperatively SNR and signal strength increased significantly in all patients ( p < 0.001). The SNR was better at discriminating poor from acceptable and good scans than signal strength ( area under the receiver operating curve: 0.879 and 0.810, respectively). Postoperative macular thickness overall showed a significant increase ( p = 0.005), most evident in patients with posterior cataracts ( p = 0.028). Conclusions: OCT imaging is influenced by cataract; image quality is reduced preoperatively and macular thickness measurements are slightly increased postoperatively. In individual patients, OCT scans remain reliable for gross clinical interpretation, even in the presence of cataract.
引用
收藏
页码:1259 / 1262
页数:4
相关论文
共 50 条
  • [1] Influence of cataract on optical coherence tomography image quality and retinal thickness (vol 90, pg 1259, 2006)
    van Velthoven, M. E. J.
    van der Linden, M. H.
    de Smet, M. D.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (12) : 1695 - 1695
  • [2] Retinal thickness immediately after cataract surgery measured by optical coherence tomography
    Grewing, R
    Becker, H
    OPHTHALMIC SURGERY AND LASERS, 2000, 31 (03): : 215 - 217
  • [3] Thickness Profiles of Retinal Layers by Optical Coherence Tomography Image Segmentation
    Bagci, Ahmet Murat
    Shahidi, Mahnaz
    Ansari, Rashid
    Blair, Michael
    Blair, Norman Paul
    Zelkha, Ruth
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (05) : 679 - 687
  • [4] Retinal thickness measurements with optical coherence biometry and optical coherence tomography
    Resch, Miklos D.
    Takats, Judit
    Csakany, Bela
    Maneschg, Otto
    Marsovszky, Laszlo
    Szabo, Antal
    Papp, Andras
    Nemeth, Janos
    SPEKTRUM DER AUGENHEILKUNDE, 2014, 28 (03) : 121 - 125
  • [5] Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer
    Konno, S
    Akiba, J
    Yoshida, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01): : 57 - 61
  • [7] Optical coherence tomography of macular thickness after cataract surgery
    Sourdille, P
    Santiago, PY
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (02): : 256 - 261
  • [8] The relationship between the optical density of cataract and its influence on retinal nerve fibre layer thickness measured with spectral domain optical coherence tomography
    Kok, Pauline H. B.
    van den Berg, Thomas J. T. P.
    van Dijk, Hille W.
    Stehouwer, Marilette
    van der Meulen, Ivanka J. E.
    Mourits, Maarten P.
    Verbraak, Frank D.
    ACTA OPHTHALMOLOGICA, 2013, 91 (05) : 418 - 424
  • [9] Quantifying the influence of Bessel beams on image quality in optical coherence tomography
    Andrea Curatolo
    Peter R. T. Munro
    Dirk Lorenser
    Parvathy Sreekumar
    C. Christian Singe
    Brendan F. Kennedy
    David D. Sampson
    Scientific Reports, 6
  • [10] Quantifying the influence of Bessel beams on image quality in optical coherence tomography
    Curatolo, Andrea
    Munro, Peter R. T.
    Lorenser, Dirk
    Sreekumar, Parvathy
    Singe, C. Christian
    Kennedy, Brendan F.
    Sampson, David D.
    SCIENTIFIC REPORTS, 2016, 6