摘要
Aims Macular disorders are investigated generally with optical coherence tomography (OCT). Aim of our study was to investigate the accuracy of optical coherence biometry (partial interferometry) in eyes with increased central retinal thickness (CRT) due to macular diseases. Methods CRT was measured on 12 eyes of 12 patients (age 66.8 +/- 5.7 years) by spectral domain OCT (Zeiss Cirrus). Reason of increased CRT was diabetic macular edema in 7 cases, serous neuroretinal detachment in 3 cases, and epiretinal membrane in 2 cases. Optical coherence biometry was performed on the same eyes using Lenstar LS900 (Haag-Streit AG). The Lenstar scans regarding retinal thickness were analyzed after manual adjustment and were correlated with the OCT data. Results CRT was measured to be 578.0 +/- 60.8 mu m (Standard Deviation) by OCT. In contrast, Lenstar measurments comprised only 467.3 +/- 33.2 mu m. The difference between the two instruments was significant (p = 0.018, Wilcoxon-test), and no significant correlation could be found (p = 0.811, Spearman rank correlation test). Conclusion CRT-after manual adjustment-can be measured with optical coherence biometry utilizing partial interferometry. Optical coherence biometry needs improvement in CRT measurements. Central retinal thickness measurements with optical coherence biometry applying Lenstar LS900 is limited in macular pathologies such as epiretinal membrane, macular edema, or exsudative agerelated macular degeneration.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [2] Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer
    Konno, S
    Akiba, J
    Yoshida, A
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01): : 57 - 61
  • [3] Reproducibility of retinal thickness measurements using Optical Coherence Tomography
    Wang, RC
    Koozekanani, D
    Herderick, EE
    Roberts, C
    Katz, SE
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [4] Automated measurements of retinal thickness with optical coherence tomography - Reply
    Ray, R
    Stinnett, SS
    Jaffe, GJ
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 351 - 351
  • [5] Errors in retinal thickness measurements obtained by optical coherence tomography
    Sadda, SR
    Wu, ZQ
    Walsh, AC
    Richine, L
    Dougall, J
    Cortez, R
    LaBree, LD
    [J]. OPHTHALMOLOGY, 2006, 113 (02) : 285 - 293
  • [6] Retinal thickness measurements with optical coherence biometry and optical coherence tomography [Messung der Netzhautdicke mittels Optischer Kohärenzbiometrie und Optischer Kohärenztomografie]
    Resch M.D.
    Takáts J.
    Csákány B.
    Maneschg O.
    Marsovszky L.
    Szabó A.
    Papp A.
    Németh J.
    [J]. Spektrum der Augenheilkunde, 2014, 28 (3) : 121 - 125
  • [7] Reproducibility of retinal thickness measurements using optical coherence tomography (OCT)
    Liebmann, JM
    Baumann, M
    Gentile, RC
    DeLuca, R
    Ozols, A
    Chew, SJ
    Ritch, R
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 4464 - 4464
  • [8] Accuracy of retinal thickness measurements obtained with Cirrus optical coherence tomography
    Keane, P. A.
    Mand, P. S.
    Liakopoulos, S.
    Walsh, A. C.
    Sadda, S. R.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (11) : 1461 - 1467
  • [9] MACULAR THICKNESS MEASUREMENTS IN CENTRAL RETINAL ARTERY OCCLUSION BY OPTICAL COHERENCE TOMOGRAPHY
    Chen, San-Ni
    Hwang, Jiunn-Feng
    Chen, Yan-Ting
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (04): : 730 - 737
  • [10] Choroidal thickness measurements with optical coherence tomography in branch retinal vein occlusion
    Muge Coban-Karatas
    Rana Altan-Yaycioglu
    Burak Ulas
    Selcuk Sizmaz
    Handan Canan
    Cagla Sariturk
    [J]. International Journal of Ophthalmology, 2016, (05) : 725 - 729