Retinal thickness measurements with optical coherence biometry and optical coherence tomography [Messung der Netzhautdicke mittels Optischer Kohärenzbiometrie und Optischer Kohärenztomografie]

被引:0
|
作者
Resch M.D. [1 ]
Takáts J. [2 ]
Csákány B. [1 ]
Maneschg O. [1 ]
Marsovszky L. [1 ]
Szabó A. [1 ]
Papp A. [1 ]
Németh J. [1 ]
机构
[1] Department of Ophthalmology, Semmelweis University, 1083 Budapest
[2] Department of Ophthalmology, Military Hospital-State Health Centre, Budapest
关键词
Age-related macular degeneration; Axial length; Central retinal thickness; Epiretinal membrane; Macular edema; Optical coherence biometry; Optical coherence tomography;
D O I
10.1007/s00717-014-0220-y
中图分类号
学科分类号
摘要
Aims: Macular disorders are investigated generally with optical coherence tomography (OCT). Aim of our study was to investigate the accuracy of optical coherence biometry (partial interferometry) in eyes with increased central retinal thickness (CRT) due to macular diseases. Methods: CRT was measured on 12 eyes of 12 patients (age 66.8 ± 5.7 years) by spectral domain OCT (Zeiss Cirrus). Reason of increased CRT was diabetic macular edema in 7 cases, serous neuroretinal detachment in 3 cases, and epiretinal membrane in 2 cases. Optical coherence biometry was performed on the same eyes using Lenstar LS900 (Haag-Streit AG). The Lenstar scans regarding retinal thickness were analyzed after manual adjustment and were correlated with the OCT data. Results: CRT was measured to be 578.0 ± 60.8 μm (Standard Deviation) by OCT. In contrast, Lenstar measurments comprised only 467.3 ± 33.2 μm. The difference between the two instruments was significant (p = 0.018, Wilcoxon-test), and no significant correlation could be found (p = 0.811, Spearman rank correlation test). Conclusion: CRT-after manual adjustment-can be measured with optical coherence biometry utilizing partial interferometry. Optical coherence biometry needs improvement in CRT measurements. Central retinal thickness measurements with optical coherence biometry applying Lenstar LS900 is limited in macular pathologies such as epiretinal membrane, macular edema, or exsudative agerelated macular degeneration. © 2014 Springer-Verlag Wien.
引用
收藏
页码:121 / 125
页数:4
相关论文
共 50 条
  • [1] Fallstricke in der Netzhautbildgebung mittels optischer KohärenztomographiePitfalls in retinal optical coherence tomography imaging
    S. Schmitz-Valckenberg
    C. K. Brinkmann
    M. Fleckenstein
    B. Heimes
    S. Liakopoulos
    G. Spital
    F. G. Holz
    [J]. Der Ophthalmologe, 2017, 114 (3): : 275 - 290
  • [2] Examination of the cornea using optical coherence tomography [Untersuchungen der hornhaut mittels optischer kohärenztomographie]
    Wirbelauer C.
    Scholz C.
    Hoerauf H.
    Bastian G.O.
    Engelhardt R.
    Birngruber R.
    Laqua H.
    [J]. Der Ophthalmologe, 2001, 98 (2): : 151 - 156
  • [3] Christbaumschmuckkatarakt dargestellt mittels optischer KohärenztomographieChristmas Tree Cataract Imaged with Optical Coherence Tomography
    Lars H. B. Mackenbrock
    Jan N. Weindler
    Victor A. Augustin
    Gerd U. Auffarth
    Ramin Khoramnia
    [J]. Die Ophthalmologie, 2023, 120 (9) : 885 - 885
  • [4] Corneal epithelial thickness measured by Fourier-domain optical coherence tomography; [Die korneale Epitheldicke und ihre Messung mittels Fourier Domain optischer Kohärenztomographie]
    Wang T.
    Li F.
    Wang S.
    Shi W.
    [J]. Spektrum der Augenheilkunde, 2016, 30 (1) : 3 - 9
  • [5] Bildgebende Diagnostik der aktinischen Porokeratose mittels optischer Kohärenztomographie (OCT)Imaging of actinic porokeratosis by optical coherence tomography (OCT)
    V. von Felbert
    M. Neis
    M. Megahed
    F. Spöler
    [J]. Der Hautarzt, 2008, 59 (11): : 877 - 879
  • [6] Reproduzierbarkeit der Goniometrie mittels spaltlampen-adaptierter optischer KohärenztomographieReproducibility of goniometry with slitlamp-adapted optical coherence tomography
    A. Karandish
    C. Wirbelauer
    H. Häberle
    D. T. Pham
    [J]. Der Ophthalmologe, 2004, 101 (6): : 608 - 613
  • [7] Retinal thickness measurements with optical coherence biometry and optical coherence tomography
    Resch, Miklos D.
    Takats, Judit
    Csakany, Bela
    Maneschg, Otto
    Marsovszky, Laszlo
    Szabo, Antal
    Papp, Andras
    Nemeth, Janos
    [J]. SPEKTRUM DER AUGENHEILKUNDE, 2014, 28 (03) : 121 - 125
  • [8] Measurement of accommodation using optical biometry [Messung der Akkommodation Mittels Optischer Biometrie]
    Nurispahic A.
    Kotliar K.
    Lanzl I.
    [J]. Der Ophthalmologe, 2008, 105 (4): : 369 - 375
  • [9] Charakterisierung von Stimmlippen mittels optischer KohärenztomographieOptical coherence tomography in the diagnosis of vocal folds
    K. Lüerßen
    H. Lubatschowski
    K. Ursinus
    H. Gasse
    R. Koch
    M. Ptok
    [J]. HNO, 2006, 54 (8) : 611 - 615
  • [10] Retinal imaging with optical coherence tomography in multiple sclerosis: novel aspectsRetinale Bildgebung mittels optischer Kohärenztomographie bei multipler Sklerose: neue Aspekte
    Elisabeth Olbert
    Walter Struhal
    [J]. Wiener Medizinische Wochenschrift, 2022, 172 : 329 - 336