Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer

被引:60
|
作者
Konno, S [1 ]
Akiba, J [1 ]
Yoshida, A [1 ]
机构
[1] Asahikawa Med Coll, Dept Ophthalmol, Asahikawa, Hokkaido 0788510, Japan
关键词
retinal thickness; optical coherence tomography; scanning retinal thickness analyzer;
D O I
10.1097/00006982-200102000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the reproducibility of retinal thickness measurements in normal subjects and to compare foveal thickness using optical coherence tomography (OCT) and the scanning retinal thickness analyzer (RTA). Methods: Two examiners performed foveal thickness measurements in 24 eyes of 12 healthy subjects using both OCT and the scanning RTA. Intraclass correlation coefficients (ICC) (intra-examiner and inter-examiner) were calculated for the paired foveal thickness measurements obtained with each instrument. Results: The average foveal thicknesses measured with OCT and the scanning RTA were 155.1 +/- 14.9 mum and 107.8 +/- 18.6 mum, respectively. The intra-examiner ICCs from the two sessions using the OCT and the scanning RTA were 0.99 and 0.78 and 0.89 and 0.99, respectively. The inter-examiner ICCs of the OCT and the scanning RTA were 0.99 and 0.99, respectively. There was a significant correlation between the foveal thickness measurements with these two instruments (R-2 = 0.629, P < 0.0001). Conclusion: The foveal thicknesses measured using OCT and the scanning RTA in healthy subjects agreed with the previously reported data on foveal thickness. Both instruments can reproducibly quantitate foveal thickness.
引用
收藏
页码:57 / 61
页数:5
相关论文
共 50 条
  • [1] Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography
    Neubauer, AS
    Priglinger, S
    Ullrich, S
    Bechmann, M
    Thiel, MJ
    Ulbig, MW
    Kampik, A
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (06): : 596 - 601
  • [2] Reproducibility of measurements of the peripapillary retinal nerve fibre layer thickness. Optical coherence tomography versus retinal thickness analyzer
    Krist, R
    Hoffmann, EM
    Schwenn, O
    [J]. OPHTHALMOLOGE, 2005, 102 (12): : 1175 - +
  • [3] Retinal thickness in diabetic retinopathy - Comparison of optical coherence tomography, the retinal thickness analyzer, and fundus photography
    Goebel, W
    Franke, R
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2006, 26 (01): : 49 - 57
  • [5] Retinal thickness measurements with optical coherence biometry and optical coherence tomography
    Resch, Miklos D.
    Takats, Judit
    Csakany, Bela
    Maneschg, Otto
    Marsovszky, Laszlo
    Szabo, Antal
    Papp, Andras
    Nemeth, Janos
    [J]. SPEKTRUM DER AUGENHEILKUNDE, 2014, 28 (03) : 121 - 125
  • [6] Retinal maps: Retinal thickness analyzer (RTA) compared to optical coherence tomography (OCT).
    Neubauer, AS
    Priglinger, S
    Thiel, M
    Bechmann, M
    Ulbig, MW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S793 - S793
  • [7] Reproducibility of foveal thickness measurements obtained by retinal thickness analyzer (RTA) compared to optical coherence tomography (OCT).
    Neubauer, AS
    Thiel, M
    Niederdellmann, C
    Bechmann, M
    Ulbig, MW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S173 - S173
  • [8] Reproducibility of retinal thickness measurements using Optical Coherence Tomography
    Wang, RC
    Koozekanani, D
    Herderick, EE
    Roberts, C
    Katz, SE
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [9] Automated measurements of retinal thickness with optical coherence tomography - Reply
    Ray, R
    Stinnett, SS
    Jaffe, GJ
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 351 - 351
  • [10] Errors in retinal thickness measurements obtained by optical coherence tomography
    Sadda, SR
    Wu, ZQ
    Walsh, AC
    Richine, L
    Dougall, J
    Cortez, R
    LaBree, LD
    [J]. OPHTHALMOLOGY, 2006, 113 (02) : 285 - 293