Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer

被引:60
|
作者
Konno, S [1 ]
Akiba, J [1 ]
Yoshida, A [1 ]
机构
[1] Asahikawa Med Coll, Dept Ophthalmol, Asahikawa, Hokkaido 0788510, Japan
关键词
retinal thickness; optical coherence tomography; scanning retinal thickness analyzer;
D O I
10.1097/00006982-200102000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the reproducibility of retinal thickness measurements in normal subjects and to compare foveal thickness using optical coherence tomography (OCT) and the scanning retinal thickness analyzer (RTA). Methods: Two examiners performed foveal thickness measurements in 24 eyes of 12 healthy subjects using both OCT and the scanning RTA. Intraclass correlation coefficients (ICC) (intra-examiner and inter-examiner) were calculated for the paired foveal thickness measurements obtained with each instrument. Results: The average foveal thicknesses measured with OCT and the scanning RTA were 155.1 +/- 14.9 mum and 107.8 +/- 18.6 mum, respectively. The intra-examiner ICCs from the two sessions using the OCT and the scanning RTA were 0.99 and 0.78 and 0.89 and 0.99, respectively. The inter-examiner ICCs of the OCT and the scanning RTA were 0.99 and 0.99, respectively. There was a significant correlation between the foveal thickness measurements with these two instruments (R-2 = 0.629, P < 0.0001). Conclusion: The foveal thicknesses measured using OCT and the scanning RTA in healthy subjects agreed with the previously reported data on foveal thickness. Both instruments can reproducibly quantitate foveal thickness.
引用
收藏
页码:57 / 61
页数:5
相关论文
共 50 条
  • [31] Comparability of retinal thickness measurements using different scanning protocols on spectral-domain optical coherence tomography
    Milton C. Chew
    Louis W. Lim
    Eujin Tan
    Colin S. Tan
    [J]. International Ophthalmology, 2016, 36 : 791 - 797
  • [32] Retinal thickness study with optical coherence tomography in patients with diabetes
    Sánchez-Tocino, H
    Alvarez-Vidal, A
    Maldonado, MJ
    Moreno-Montañés, J
    García-Layana, A
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 (05) : 1588 - 1594
  • [33] A new method of determining retinal thickness for optical coherence tomography
    Gong, X
    Bartsch, DUG
    Freeman, WR
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U598 - U598
  • [34] Inter-Session Repeatability of Retinal Layer Thickness Measurements in Optical Coherence Tomography
    Tian, Jing
    Bates, Nathan
    Somfai, Gabor Mark
    DeBuc, Delia
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [35] Repeatability of retinal thickness measurements in children using spectral domain optical coherence tomography
    Boned-Murillo, Ana
    Garcia, Diana Perez
    Diaz, Maria Dolores
    Cano, Ana Sanchez
    Remon, Leon
    Hospital, Elvira Orduna
    Fernandez-Espinosa, Guisela
    Pinilla, Maria Sopena
    Rivases, Guillermo Perez
    Lozano, Isabel Pinilla
    [J]. ACTA OPHTHALMOLOGICA, 2022, 100
  • [36] Comparison of retinal thickness measurements among four different optical coherence tomography devices
    Nam, Ki Tae
    Yun, Cheolmin
    Seo, Myungho
    Ahn, Somin
    Oh, Jaeryung
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01)
  • [37] Optical Coherence Tomography Retinal Thickness and Volume Measurements in X-Linked Retinoschisis
    Andreoli, Michael T.
    Lim, Jennifer I.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (03) : 567 - 573
  • [38] Comparison of retinal thickness measurements among four different optical coherence tomography devices
    Ki Tae Nam
    Cheolmin Yun
    Myungho Seo
    Somin Ahn
    Jaeryung Oh
    [J]. Scientific Reports, 14
  • [39] Reproducibility of Retinal Thickness Measurements in Healthy Subjects Using Spectralis Optical Coherence Tomography
    Menke, Marcel N.
    Dabov, Simeon
    Knecht, Pascal
    Sturm, Veit
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (03) : 467 - 472
  • [40] A robust algorithm for retinal thickness measurements using optical coherence tomography (Stratus OCT)
    Gregori, G
    Knighton, RW
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U50 - U50