Reproducibility of measurements of the peripapillary retinal nerve fibre layer thickness. Optical coherence tomography versus retinal thickness analyzer

被引:3
|
作者
Krist, R
Hoffmann, EM
Schwenn, O
机构
[1] Univ Mainz, Augenklin, D-55131 Mainz, Germany
[2] Burger Hosp, Frankfurt, Germany
来源
OPHTHALMOLOGE | 2005年 / 102卷 / 12期
关键词
peripapillary retinal nerve fibre layer thickness; optical coherence tomography; retinal thickness analyzer; reproducibility;
D O I
10.1007/s00347-005-1229-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The aim of this study was to compare the intra- and inter-examiner reproducibility of measurements obtained by optical coherence tomography (OCT) and retinal thickness analyzer (RTA). Patients and methods. During a period of 2 months, 22 eyes of 16 patients and 6 healthy subjects were included. Two examiners (EMH, RK) successively performed three measurements of the peripapillary retinal nerve fibre layer (RNFL) thickness with RTA and OCT. The reproducibility of three individual measurements of one examiner (intra-examiner) as well as the reproducibility of the measurements between both examiners (inter-examiner) was evaluated using the Friedman test and sign test. Results. The average thickness of the peripapillary RNFL was 154.4 mu m for the first investigator (EMH) and 155.1 mu m for the other investigator (RK) measured with RTA. The results obtained by OCT were 137.3 mu m (EMH) and 138.9 mu m (RK), respectively, generally indicating a threefold smaller range. Comparing the three measurements of one single examiner, no appreciable intra-observer dependency neither for RTA (EMH: p=0.19, RK: p=0.95) norfor OCT (EMH:p=0.51, RK:p=0.62) was observed. Inter-examiner analysis for RTA and OCT also revealed an acceptable reproducibility. Conclusions. Measurements of peripapillary RNFL thickness using RTA and OCT exhibited intra- and inter-observer agreement.
引用
收藏
页码:1175 / +
页数:5
相关论文
共 50 条
  • [1] Reproducibility of peripapillary retinal nerve fibre layer thickness measurements with spectral domain optical coherence tomography in normal and glaucomatous eyes
    Mansoori, Tarannum
    Viswanath, Kalluri
    Balakrishna, Nagalla
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (05) : 685 - 688
  • [2] Retinal nerve fibre layer thickness measurements in myopia by optical coherence tomography
    Bubella, R. Morreale
    Bubella, D. Morreale
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [3] Reproduzierbarkeit der Messung der peripapillären NervenfaserschichtdickeOptische Kohärenztomographie versus Retinal Thickness AnalyzerReproducibility of measurements of the peripapillary retinal nerve fibre layer thicknessOptical coherence tomography versus retinal thickness analyzer
    R. Krist
    E. M. Hoffmann
    O. Schwenn
    Der Ophthalmologe, 2005, 102 : 1175 - 1180
  • [4] Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer
    Konno, S
    Akiba, J
    Yoshida, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01): : 57 - 61
  • [5] Reliability of retinal thickness and retinal Fibre layer thickness measurements with the Optical Coherence Tomographer
    Simms, C
    Munger, R
    O'Connor, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S125 - S125
  • [6] Retinal nerve fibre layer thickness measurements using optical coherence tomography in migraine patients
    Martinez, A.
    Proupim, N.
    Sanchez, M.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (08) : 1069 - 1075
  • [7] Retinal nerve fibre layer thickness measurement reproducibility improved with spectral domain optical coherence tomography
    Kim, J. S.
    Ishikawa, H.
    Sung, K. R.
    Xu, J.
    Wollstein, G.
    Bilonick, R. A.
    Gabriele, M. L.
    Kagemann, L.
    Duker, J. S.
    Fujimoto, J. G.
    Schuman, J. S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (08) : 1057 - 1063
  • [8] Analysis of the Peripapillary Retinal Nerve Fibre Layer Thickness Using Optical Coherence Tomography in Traumatic Optic Neuropathy
    Ahn, Hee Bae
    Hur, Mun Chong
    Lee, Jin Wha
    NEURO-OPHTHALMOLOGY, 2012, 36 (02) : 42 - 47
  • [9] Peripapillary retinal nerve fibre layer thickness in highly myopic Caucasians as measured by Stratus optical coherence tomography
    Vemon, S. A.
    Rotchford, A. P.
    Negi, A.
    Ryatt, S.
    Tattersal, C.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (08) : 1076 - 1080
  • [10] Reproducibility of measurements of the retinal nerve fibre layer thickness. Comparison of OCT with NFA and HRT techniques
    Klemm, M
    Rumberger, E
    Walter, A
    Richard, G
    OPHTHALMOLOGE, 2002, 99 (05): : 345 - 351