Influence of cataract on optical coherence tomography image quality and retinal thickness

被引:99
|
作者
van Velthoven, M. E. J.
van der Linden, M. H.
de Smet, M. D.
Faber, D. J.
Verbraak, F. D.
机构
[1] Acad Med Ctr, Dept Ophthalmol, NL-1105 AZ Amsterdam, Netherlands
[2] OMC Haarlem, Haarlem, Netherlands
关键词
D O I
10.1136/bjo.2004.097022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: As optical coherence tomography ( OCT) is widely used for diagnosis and monitoring of ocular pathology, especially in the elderly people, the influence of cataract on image quality and macular retinal thickness was studied. Methods: In 29 patients scheduled for cataract surgery, preoperative and postoperative OCT scans were obtained. Cataracts were categorised as nuclear, posterior or cortical. Parameters for image quality ( signal-to-noise ratio ( SNR)) and signal strength and macular thickness were compared. A three-level expert grading scale was used to evaluate the discriminative abilities of SNR and signal strength. Results: Nuclear cataracts ( n = 12) provided better preoperative scans ( higher SNR/ signal strength) than posterior ( n = 7) and cortical ( n = 10) cataracts ( p < 0.004). Postoperatively SNR and signal strength increased significantly in all patients ( p < 0.001). The SNR was better at discriminating poor from acceptable and good scans than signal strength ( area under the receiver operating curve: 0.879 and 0.810, respectively). Postoperative macular thickness overall showed a significant increase ( p = 0.005), most evident in patients with posterior cataracts ( p = 0.028). Conclusions: OCT imaging is influenced by cataract; image quality is reduced preoperatively and macular thickness measurements are slightly increased postoperatively. In individual patients, OCT scans remain reliable for gross clinical interpretation, even in the presence of cataract.
引用
收藏
页码:1259 / 1262
页数:4
相关论文
共 50 条
  • [21] Retinal thickness in diabetic retinopathy - A comparison between optical coherence tomography and the retinal thickness analyser
    Goebel, W
    Franke, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U423 - U423
  • [22] Image Quality Affects Macular and Retinal Nerve Fiber Layer Thickness Measurements on Fourier-Domain Optical Coherence Tomography
    Huang, Jingjing
    Liu, Xing
    Wu, Ziqiang
    Sadda, Srinivas
    OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (03) : 216 - 221
  • [23] Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography
    Neubauer, AS
    Priglinger, S
    Ullrich, S
    Bechmann, M
    Thiel, MJ
    Ulbig, MW
    Kampik, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (06): : 596 - 601
  • [24] Optical coherence tomography angiography image quality assessment at varying retinal expertise levels
    Woetzel, Anne K.
    Lauermann, Jost L.
    Kreitz, Kiana
    Alnawaiseh, Maged
    Clemens, Christoph R.
    Eter, Nicole
    Alten, Florian
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2019, 31 (02): : 161 - 167
  • [25] Image Quality and Retinal Vascular Metrics in the Community using Optical Coherence Tomography Angiography
    Kherani, Saleema A.
    Guo, Xinxing
    Arsiwala, Lubaina
    Dong, Yanan
    Kong, Xiangrong
    Sharrett, A. Richey
    Ramulu, Pradeep Y.
    Huang, David
    Lujan, Brandon J.
    Tomlinson, Alexander
    Abraham, Alison
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [26] Optical coherence tomography 3: Delineation of the outer neural retinal boundary and its influence on retinal thickness measurements
    Costa, RA
    Calucci, D
    Skaf, M
    Cardillo, JA
    Castro, JC
    Melo, LA
    Martins, MC
    Kaiser, PK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (07) : 2399 - 2406
  • [27] Automatic quality analysis of retinal optical coherence tomography
    Kauer, J.
    Gawlik, K.
    Beckers, I.
    Zimmermann, H. G.
    Kadas, E. M.
    Bereuter, C.
    Hausser, F.
    Paul, F.
    Brandt, A. U.
    MULTIPLE SCLEROSIS JOURNAL, 2018, 24 : 438 - 439
  • [28] Evaluation of potential image acquisition pitfalls during optical coherence tomography and their influence on retinal image segmentation
    Somfai, Gabor Mark
    Salinas, Harry M.
    Puliafito, Carmen A.
    Fernandez, Delia Cabrera
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (04)
  • [29] Optical coherence tomography: influence of contrast concentration on image quality and diagnostic confidence
    Blachutzik, Florian
    Achenbach, Stephan
    Nef, Holger
    Hamm, Christian
    Dorr, Oliver
    Boeder, Niklas
    Marwan, Mohamed
    Trobs, Monique
    Schneider, Reinhard
    Rother, Jens
    Schlundt, Christian
    HEART AND VESSELS, 2017, 32 (06) : 653 - 659
  • [30] Optical coherence tomography: influence of contrast concentration on image quality and diagnostic confidence
    Florian Blachutzik
    Stephan Achenbach
    Holger Nef
    Christian Hamm
    Oliver Dörr
    Niklas Boeder
    Mohamed Marwan
    Monique Tröbs
    Reinhard Schneider
    Jens Röther
    Christian Schlundt
    Heart and Vessels, 2017, 32 : 653 - 659