Multi-slit prompt-gamma camera for locating of distal dose falloff in proton therapy

被引:2
|
作者
Park, Jong Hoon [1 ]
Kim, Sung Hun [1 ]
Ku, Youngmo [1 ]
Kim, Chan Hyeong [1 ]
Lee, Han Rim [2 ]
Jeong, Jong Hwi [3 ]
Lee, Se Byeong [3 ]
Shin, Dong Ho [4 ]
机构
[1] Hanyang Univ, Dept Nucl Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[2] Korea Atom Energy Res Inst, Neutron Utilizat Technol Div, Daejeon 34129, South Korea
[3] Natl Canc Ctr, Proton Therapy Ctr, Goyang Si 10408, Gyonggi Do, South Korea
[4] Elect & Telecommun Res Inst, IT Convergence Technol Res Lab, Daejeon 34129, South Korea
关键词
Proton therapy; Prompt gamma; Beam range verification; Distal dose falloff; BEAM RANGE VERIFICATION; COMPTON CAMERA; RADIATION HARDNESS; PENCIL BEAMS; SLIT CAMERA; TARGETS; SYSTEM;
D O I
10.1016/j.net.2019.03.008
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this research, a multi-slit prompt-gamma camera was developed to locate the distal dose falloff of the proton beam spots in spot scanning proton therapy. To see the performance of the developed camera, therapeutic proton beams were delivered to a solid plate phantom and then the prompt gammas from the phantom were measured using the camera. Our results show that the camera locates the 90% distal dose falloff (= d90%), within about 2-3 mm of error for the spots which are composed 3.8 x 10(8) protons or more. The measured location of d90% is not very sensitive to the irradiation depth of the proton beam (i.e., the depth of proton beam from the phantom surface toward which the camera is located). Considering the number of protons per spot for the most distal spots in typical treatment cases (i.e., 2 Gy dose divided in 2 fields), the camera can locate d90% only for a fraction of the spots depending on the treatment cases. However, the information of those spots is still valuable in that, in the multi-slit prompt-gamma camera, the distal dose falloff of the spots is located solely based on prompt gamma measurement, i.e., not referring to Monte Carlo simulation. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:1406 / 1416
页数:11
相关论文
共 50 条
  • [21] Two-dimensional measurement of the prompt-gamma distribution for proton dose distribution monitoring
    Lee, Han Rim
    Park, Jong Hoon
    Kim, Han Sung
    Kim, Chan Hyeong
    Kim, Seonghoon
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1385 - 1389
  • [22] Detection of mixed-range proton pencil beams with a prompt gamma slit camera
    Priegnitz, M.
    Helmbrecht, S.
    Janssens, G.
    Perali, I.
    Smeets, J.
    Stappen, F. Vander
    Sterpin, E.
    Fiedler, F.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (02): : 855 - 871
  • [23] Classification of the source of treatment deviation in proton therapy using prompt-gamma imaging information
    Khamfongkhruea, Chirasak
    Berthold, Jonathan
    Janssens, Guillaume
    Petzoldt, Johannes
    Smeets, Julien
    Pausch, Guntram
    Richter, Christian
    MEDICAL PHYSICS, 2020, 47 (10) : 5102 - 5111
  • [24] Towards clinical application: Potential margin reduction in proton therapy with prompt-gamma imaging
    Bertschi, S.
    Berthold, J.
    Pietsch, J.
    Smeets, J.
    Janssens, G.
    Stuetzer, K.
    Richter, C.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1586 - S1588
  • [25] Range verification in proton therapy: Can prompt-gamma imaging identify the source of deviation?
    Khamfongkhruea, C.
    Janssens, G.
    Petzoldt, J.
    Smeets, J.
    Pausch, G.
    Richter, C.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S296 - S297
  • [26] Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam
    Min, C. H.
    Kim, J. W.
    Youn, M. Y.
    Kim, C. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 562 - 565
  • [27] REAL-TIME PROTON BEAM RANGE MONITORING BY MEANS OF PROMPT-GAMMA DETECTION WITH A COLLIMATED CAMERA
    Roellinghoff, F.
    Benilov, A.
    Dauvergne, D.
    Dedes, G.
    Freud, N.
    Krimmer, J.
    Letang, J. M.
    Prieels, D.
    Ray, C.
    Richard, M. H.
    Smeets, J.
    Stichelbaut, F.
    Testa, E.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S120 - S121
  • [28] Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera
    Roellinghoff, F.
    Benilov, A.
    Dauvergne, D.
    Dedes, G.
    Freud, N.
    Janssens, G.
    Krimmer, J.
    Letang, J. M.
    Pinto, M.
    Prieels, D.
    Ray, C.
    Smeets, J.
    Stichelbaut, F.
    Testa, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05): : 1327 - 1338
  • [29] Design optimization of a 2D prompt-gamma measurement system for proton dose verification
    Lee, Han Rim
    Park, Jong Hoon
    Kim, Chan Hyeong
    Min, Chul Hee
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (02) : 239 - 242
  • [30] Design optimization of a 2D prompt-gamma measurement system for proton dose verification
    Han Rim Lee
    Jong Hoon Park
    Chan Hyeong Kim
    Chul Hee Min
    Journal of the Korean Physical Society, 2012, 61 : 239 - 242